文献速递关节外科

在广泛骨关节炎人群中选择性使用骨水泥与非骨水泥股骨柄行初次全髋关节置换术能否获得可比结果

Can Selected Use of Cemented and Uncemented Femoral Components in a Broad Population Produce Comparable Results Following Primary Total Hip Arthroplasty for Osteoarthritis?
PubMed 文献 · J Arthroplasty · 2023-04-10

研究纳入2000至2018年5809例因骨关节炎行初次全髋关节置换术的患者,比较骨水泥股骨柄(1304例)与扩髓-锉磨三锥度非骨水泥股骨柄(4505例)的结果。10年时骨水泥组全因翻修呈升高趋势(HR 1.6,P=0.053),全因再手术较高(HR 1.6,P=0.02),但术中假体周围骨折较少(HR 0.21,P<0.001),术后骨折无差异(HR 0.99,P=0.96)。在≥75岁亚组中,10年翻修或再手术无差异。

要点

  • 骨水泥组10年全因再手术较高(HR 1.6,P=0.02),全因翻修呈升高趋势(HR 1.6,P=0.053)。
  • 骨水泥组术中假体周围骨折较少(HR 0.21,P<0.001),术后骨折无差异(HR 0.99,P=0.96)。
  • ≥75岁亚组中,骨水泥与非骨水泥股骨柄10年翻修或再手术无差异。

核心结论

  • 与骨水泥股骨柄相比,在包括≥75岁患者的选择性人群中,使用扩髓-锉磨三锥度非骨水泥股骨柄与更多术中骨折相关,但10年假体生存率无差异。
  • 这些结果与部分登记数据不同,提示特定非骨水泥假体由经验丰富术者在选择患者中植入,在广泛患者人群中可取得与骨水泥假体相当的效果。

研究设计与样本

  • 2000年至2018年共行5809例初次全髋关节置换术,其中骨水泥股骨柄1304例,扩髓-锉磨三锥度非骨水泥股骨柄4505例。
  • 假体选择由术者决定;骨水泥组年龄更大、女性更多、体重指数略低;对≥75岁患者进行亚组分析;采用统计加权处理基线队列差异。

主要发现

  • 10年时骨水泥固定队列全因翻修呈升高趋势(HR 1.6,P=0.053),全因再手术较高(HR 1.6,P=0.02)。
  • 骨水泥固定组术中假体周围骨折较少(HR 0.21,P<0.001),但术后骨折无差异(HR 0.99,P=0.96)。
  • 在≥75岁患者中结果相同;在≥75岁亚组中,10年翻修或再手术无差异。

关键数值与推荐

  • 10年全因翻修:骨水泥组与非骨水泥组比较HR 1.6(P=0.053)。
  • 10年全因再手术:骨水泥组与非骨水泥组比较HR 1.6(P=0.02)。
  • 术中假体周围骨折:骨水泥组与非骨水泥组比较HR 0.21(P<0.001)。
  • 术后假体周围骨折:骨水泥组与非骨水泥组比较HR 0.99(P=0.96)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Registry data have demonstrated lower rates of revision and periprosthetic fracture in select cohorts with cemented femoral fixation at primary total hip arthroplasty. Whether this is true of all component designs is not known. We hypothesized that selected use of ream-and-broach triple-tapered uncemented stem designs may provide comparable results to cemented stems. METHODS: From 2000 to 2018, 5,809 primary total hip arthroplasties were performed with either a cemented (1,304) or ream-and-broach triple-tapered uncemented stem (4,505). Implant choice was at surgeon discretion. The cemented group was older, more often women, and had slightly lower body mass index. A subgroup analysis was performed on patients ≥75 years of age. Statistical weighting accounted for baseline cohort differences. RESULTS: At 10 years, there was a trend toward higher all-cause revision (hazards ratio (HR) 1.6, P = .053) and higher all-cause reoperation (HR 1.6, P = .02) in the cemented fixation cohort. The cemented fixation group had fewer intraoperative periprosthetic fractures (HR 0.21, P < .001) but no difference in postoperative fractures (HR 0.99, P = .96). The same was true in patients ≥75 years. In the ≥75-years subgroup, there was no difference in revision or reoperation at 10 years. CONCLUSION: Compared to cemented stems, the use of ream-and-broach triple-tapered uncemented stems in select patients, including those ≥75 years, was associated with more intraoperative fractures but no difference in 10-year implant survivorship. These findings are different than some registry data and suggest that specific uncemented components, implanted in selected patients by experienced surgeons, can perform as well as cemented implants in a broad patient population.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Wilson JM, Smartt AA, Abdel MP, et al. Can Selected Use of Cemented and Uncemented Femoral Components in a Broad Population Produce Comparable Results Following Primary Total Hip Arthroplasty for Osteoarthritis? J Arthroplasty. 2023. PMID: 37044223. doi:10.1016/j.arth.2023.04.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。