文献速递关节外科

维持关节线倾斜度优化功能性对线在全膝关节置换术中对体质性膝内翻患者的疗效

Maintaining Joint Line Obliquity Optimizes Outcomes of Functional Alignment in Total Knee Arthroplasty in Patients With Constitutionally Varus Knees.
PubMed 文献 · J Arthroplasty · 2023-04-14

本研究前瞻性收集300例连续机器人辅助功能性对线(FA)全膝关节置换术(TKA)数据,比较FA机械对线计划(FA(m),135例)与FA运动学对线计划(FA(k),165例)至少2年结局。FA(k)组胫骨内翻、股骨外翻及关节线倾斜度更高,遗忘关节评分-12(79.4 vs 71.6,P=.018)和活动度(125 vs 121°,P=.003)更优;体质性膝内翻患者FA(k)组遗忘关节评分改善最大(89 vs 65,P<.001)。

要点

  • FA(k)组最终假体位置关节线倾斜度更大,但整体下肢对线两组等效。
  • FA(k)组遗忘关节评分-12为79.4 vs FA(m)组71.6(P=.018),活动度125 vs 121°(P=.003)。
  • 体质性膝内翻患者FA(k)组至少2年遗忘关节评分为89 vs 65(P<.001)。

核心结论

  • 采用个体化对线计划[FA(k)]导致最终假体位置关节线倾斜度更大,但整体下肢对线相同。
  • 这与体质性膝内翻患者TKA术后2年结局改善相关。
  • 三维假体位置和关节线倾斜度独立于冠状面下肢对线影响TKA术后结局。

研究设计与样本

  • 前瞻性收集300例连续机器人辅助FA TKA数据,其中FA(m)组135例、FA(k)组165例。
  • 术前及术后2年获取患者报告结局。
  • 采用膝关节冠状面对线分类法对膝关节对线表型进行分类。

主要发现

  • 整体下肢对线两组等效。
  • 最终假体对线FA(m)与FA(k)组不同:FA(k)组胫骨内翻更高(P<.01)、股骨外翻更高(P<.01)、关节线倾斜度更高(P<.01)。
  • FA(k)组遗忘关节评分-12为79.4 vs FA(m)组71.6(P=.018)。
  • FA(k)组活动度为125 vs FA(m)组121°(P=.003)。
  • 体质性膝内翻患者FA(k)组至少2年遗忘关节评分为89 vs 65(P<.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Functional alignment (FA) strives to balance the knee soft-tissue envelope during total knee arthroplasty (TKA) using implant alignment adjustments rather than soft-tissue releases. There is a debate on how best to achieve FA. We compared minimum two-year outcomes between FA with a mechanical alignment plan [FA(m)] and FA with a kinematic alignment plan [FA(k)]. The null hypothesis was that there would be no difference in outcomes between FA(m) and FA(k). METHODS: Prospective data was collected from 300 consecutive robotic-assisted FA TKAs [135 FA(m) and 165 FA(k)]. Patient reported outcomes were obtained preoperatively and 2 years postoperatively. The coronal plane alignment of the knee classification was used to classify knee alignment phenotypes. RESULTS: Overall limb alignment was equivalent between groups. Final implant alignment was different between FA(m) and FA(k) groups, with FA(k) TKAs having higher tibial varus (P < .01), higher femoral valgus (P < .01), and higher joint line obliquity (P < .01). Patients reported higher Forgotten Joint Score-12 scores with FA(k) TKAs (79.4 versus 71.6, P = .018) and greater range of motion (125 versus 121°; P = .003). Patients who had constitutional varus reported the greatest improvement with FA(k) technique (Forgotten Joint Score at minimum 2 years of 89 versus 65; P < .001). CONCLUSION: Utilizing an individualized alignment plan [FA(k)] led to a final implant position with greater joint line obliquity, yet the same overall limb alignment. This was associated with improved outcomes at 2 years post-TKA in patients who had constitutional varus. Three-dimensional component position and joint line obliquity affect the outcomes following TKA independently of coronal limb alignment.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Clark GW, Steer RA, Khan RN, et al. Maintaining Joint Line Obliquity Optimizes Outcomes of Functional Alignment in Total Knee Arthroplasty in Patients With Constitutionally Varus Knees. J Arthroplasty. 2023. PMID: 37061140. doi:10.1016/j.arth.2023.04.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。