压配式、偏心、骨干接合延长柄及偏心扩髓技术行翻修全膝关节置换术中的对线与固定
本研究为回顾性临床与全长X线研究,纳入连续111例翻修全膝关节置换术(排除后92例),随访至少2年,评估压配式骨干接合延长柄联合偏心扩髓技术的对线与固定效果。结果显示股骨与胫骨管腔填充率均超过91%,平均髋-膝-踝角179.6°(174.9-184.0),80%在中立位±3°内,胫骨组件99.0%在±3°内,股骨组件89.5%在±3°内。作者结论认为该技术可达到目标冠状对线并提供固定。
要点
- 压配式骨干接合延长柄联合偏心扩髓技术可用于翻修全膝关节置换术的对线控制与固定。
- 平均髋-膝-踝角179.6°(174.9-184.0),80%病例在±3°以内。
- 股骨与胫骨管腔填充率在正侧位X线上均超过91%。
核心结论
- 本研究描述了一种通过压配式骨干固定实现目标冠状对线的手术规划与技术。
- 作者称这是唯一报告两平面管腔填充率及全长X线冠状对线的压配式骨干柄翻修膝关节系列。
研究设计与样本
- 回顾性临床与全长X线研究,连续纳入111例翻修全膝关节置换术,排除后92例,随访至少2年(范围2至10年)。
- 结果与新西兰关节登记数据关联以识别再翻修。
主要发现
- 股骨与胫骨管腔填充率在正位和侧位X线上均超过91%。
- 平均髋-膝-踝角为179.6°(174.9-184.0),80%病例在±3°以内。
- 髋-踝轴穿过中央Kennedy区者占76.5%,其余24.6%穿过内侧及外侧内区。
- 胫骨组件99.0%在±3°以内;股骨组件89.5%在±3°以内。
- 5膝因感染失败,3膝因股骨松动失败,1膝因脊髓灰质炎所致反屈不稳失败。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A revision total knee arthroplasty must control limb alignment, often to address the cause of failure. Press-fit stems that engage the diaphysis with cement restricted to the metaphysis constitute one fixation technique. These long stems restrict coronal alignment of the prosthesis and as a result reduce the likelihood of extreme malposition. For the same reasons, long stems can make it difficult to manipulate alignment and achieve a specific coronal alignment angle. Nevertheless, femoral stems with a tight diaphyseal fit may still occupy a small range of varus-valgus positions due to the conical distal femoral metaphysis. Pulling the reamer toward the lateral endosteum increases femoral component coronal alignment toward a valgus direction and pushing the reamer medially increases alignment in a more varus direction. A straight stem, in combination with a medially directed reaming, would result in a femoral component that overhangs medially, but an offset stem can recenter the femoral component and maintain the desired alignment. We hypothesized that diaphyseal fit plus this reaming technique can control limb coronal alignment and provide fixation. METHODS: This was a retrospective clinical and long-leg radiographic study of consecutive revision total knee arthroplasties with minimum 2-year follow-up. Outcomes were correlated with New Zealand Joint Registry data to identify rerevisions of 111 consecutive revision knee arthroplasties, 92 after exclusions, at a minimum 2-year (range, 2 to 10) follow-up. RESULTS: Mean femoral and tibial canal fill exceeded 91% on antero-posterior and lateral radiographs. The mean hip-knee-ankle angle was 179.6o (174.9-184.0) with 80% within ± 3o of neutral. The hip-ankle axis crossed the central Kennedy zone in 76.5% of cases and the other 24.6% crossed the inner medial and inner lateral zones. Tibial components: 99.0% ± 3o. Femoral components: 89.5% within ± 3o. There were 5 knees that failed due to infection, 3 from femoral loosening, and 1 due to recurvatum instability from polio. CONCLUSIONS: This study describes a surgical plan and technique for achieving target coronal alignment with press-fit diaphyseal fixation. It is the only series of revision knee arthroplasties with diaphyseal press-fit stems to report canal fill in 2 planes and coronal alignment on full-length radiographs.
引用
- Vince KG, Hoskins WT, English M, et al. Alignment and Fixation in Revision Total Knee Arthroplasty With Press-Fit, Offset, Diaphyseal-Engaging Stem Extensions, and Eccentric Reaming Technique. J Arthroplasty. 2023. PMID: 37023912. doi:10.1016/j.arth.2023.03.090
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。