双动髋臼杯与大型股骨头在翻修全髋关节置换术中的对比:一项随机对照试验的中期分析
这项多中心随机对照试验比较后路翻修全髋关节置换术中双动轴承(DM)与大型股骨头(≥36 mm)的脱位风险。中期分析共纳入146例患者,平均随访18.2个月,DM组脱位2例(2.6%),大型股骨头组3例(4.3%),差异无统计学意义(P=0.67)。结论认为翻修全髋关节置换术中两种方案脱位风险无差异,但脱位率低于预期,需继续随访。
要点
- 后路翻修全髋关节置换术中,DM组脱位率2.6%(2/76)与大型股骨头组4.3%(3/70)无显著差异(P=0.67)。
- 大型股骨头组1例经闭合复位成功且未再翻修,DM组无此情况。
- 中期分析脱位率低于预期,需继续随访。
核心结论
- 中期分析发现,翻修全髋关节置换术中双动轴承与大型股骨头的脱位风险无差异,但脱位率低于预期,需继续随访。
研究设计与样本
- 多中心随机对照试验,共146例患者随机分配至双动轴承组(76例)或大型股骨头组(70例),后路翻修全髋关节置换术。
- 双动轴承组中位有效头尺寸46 mm(范围36至59 mm);大型股骨头组包括25个36 mm头(35.7%)、41个40 mm头(58.6%)和4个44 mm头(5.7%)。
- 翻修类型包括单组件翻修71例(48.6%)、双组件翻修39例(26.7%)、二期翻修后全髋关节再植入24例(16.4%)、孤立头衬更换7例(4.8%)、半髋关节置换转为全髋关节4例(2.7%)和髋关节表面置换翻修1例(0.7%)。
主要发现
- 平均随访18.2个月(范围1.4至48.2个月),大型股骨头组脱位3例,双动轴承组脱位2例(4.3% vs 2.6%,P=0.67)。
- 大型股骨头组1例经闭合复位成功且未再翻修,双动轴承组无此情况。
- 功效分析确定每组需161例患者才能将脱位率从8.4%降至2.2%(功效=0.8,α=0.05)。
局限性
- 中期分析脱位率低于预期,需继续随访。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This multicenter randomized controlled trial evaluated if dual-mobility bearings (DM) lower the risk of dislocation compared to large femoral heads (≥36 mm) for patients undergoing revision total hip arthroplasty (THA) via a posterior approach. METHODS: A total of 146 patients were randomized to a DM (n = 76; 46 mm median effective head size, range 36 to 59 mm) or a large femoral head (n = 70; twenty-five 36 mm heads [35.7%], forty-one 40 mm heads [58.6%], and four 44 mm heads [5.7%]). There were 71 single-component revisions (48.6%), 39 both-component revisions (26.7%), 24 reimplantations of THA after 2-stage revision (16.4%), seven isolated head and liner exchanges (4.8%), four conversions of hemiarthroplasty (2.7%), and 1 revision of a hip resurfacing (0.7%). Power analysis determined that 161 patients were required in each group to lower the dislocation rate from 8.4 to 2.2% (power = 0.8, alpha = 0.05). RESULTS: At a mean of 18.2 months (range, 1.4 to 48.2), there were three dislocations in the large femoral head group compared to two in the DM cohort (4.3 versus 2.6%; P = .67). One patient in the large head group and none in the DM group were successfully treated with closed reduction without subsequent revision. CONCLUSION: Interim analysis of this randomized controlled trial found no difference in the risk of dislocation between DM and large femoral heads in revision THA, although the rate of dislocation was lower than anticipated and continued follow-up is needed.
引用
- Weintraub MT, DeBenedetti A, Nam D, et al. Dual-Mobility versus Large Femoral Heads in Revision Total Hip Arthroplasty: Interim Analysis of a Randomized Controlled Trial. J Arthroplasty. 2023. PMID: 37019309. doi:10.1016/j.arth.2023.03.089
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。