文献速递关节外科运动医学

加速度计用于评估髋关节表面置换术后随时间变化的负载不对称性

Novel Use of an Accelerometer to Assess Load Asymmetry Over Time After Hip Resurfacing Arthroplasty.
PubMed 文献 · J Arthroplasty · 2023-04-15

本研究纳入26例初次髋关节表面置换术(HRA)患者,在术前、术后3个月和6个月进行5项经验证的身体测试,用加速度计采集冲击负载与平均强度数据,用测力计采集内旋和外旋力量数据。结果显示术前和术后3个月存在显著肢体间不对称(非手术腿输出更大),术后6个月所有测试均无显著不对称;Harris髋关节评分增加与冲击不对称性降低显著相关(rs=-0.269,P=.006)。

要点

  • 术前和术后3个月多个测试存在显著不对称,均表现为非手术腿输出更大。
  • 术后6个月所有测试均未发现显著肢体间不对称。
  • Harris髋关节评分增加与冲击不对称性降低显著相关(rs=-0.269,P=.006)。

核心结论

  • 髋关节表面置换术后6个月,冲击负载和力量达到肢体间对称。
  • 可穿戴加速度计为恢复监测中区分肢体不对称提供了有用指标。

研究设计与样本

  • 本研究纳入26例初次髋关节表面置换术患者,在术前、术后3个月和6个月进行5项经验证的身体测试:立定跳远、双腿垂直跳(DLVJ)、单腿跳测试、侧向单腿跳(LSLJ)和垂直单腿跳。
  • 使用加速度计采集冲击负载和平均强度数据(g力单位),使用测力计采集内旋和外旋力量数据(磅)。
  • 采用单变量和相关分析分析肢体间不对称性。

主要发现

  • 术前,双腿垂直跳(P=.008)、单腿跳测试(P=.021)和侧向单腿跳(P=.003)的冲击负载不对称显著,双腿垂直跳(P=.010)和侧向单腿跳(P=.003)的强度不对称显著。
  • 术后3个月,双腿垂直跳(P=.005)和侧向单腿跳(P=.005)的冲击负载不对称显著,立定跳远(P=.020)、单腿跳测试(P=.042)和侧向单腿跳(P=.005)的强度不对称显著。
  • 术前和术后3个月,内旋(P=.013)和外旋(P=.037)的力量不对称显著。
  • 所有显著的不对称均表明非手术腿输出更大。
  • 术后6个月,所有测试均未发现显著不对称。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There is limited knowledge regarding usage of wearable technology to guide return to sport after hip resurfacing arthroplasty (HRA). This study evaluated the use of accelerometers to identify when symmetry is restored between operative and nonoperative limbs. METHODS: A total of 26 primary HRA patients performed 5 validated physical tests before, 3 and 6 months after HRA: broad jump, double-leg vertical jump (DLVJ), hop test, lateral single-leg jump (LSLJ), and vertical single-leg jump. Impact load and average intensity data (g-force units) were collected using accelerometers. Strength data (pounds [lbs.]) for internal and external rotation were collected with a dynamometer. Univariate and correlation analyses analyzed interlimb asymmetries. RESULTS: At preoperation, there were significant impact load asymmetries for DLVJ (P = .008), hop test (P = .021), and LSLJ (P = .003) and intensity asymmetry for DLVJ (P = .010) and LSLJ (P = .003). At 3 months, there was impact load asymmetry for DLVJ (P = .005) and LSLJ (P = .005) and intensity asymmetry for broad jump (P = .020), hop test (P = .042), and LSLJ (P = .005). There were significant strength asymmetries at preoperation and 3 months postoperation for internal (P = .013) and external rotation (P = .037). All significant asymmetries indicated the nonoperative leg had greater output. No significant asymmetries were found for any exercises at 6 months postoperation. An increase in Harris Hip Score was significantly associated with a decrease in impact asymmetry (rs = -0.269, P = .006). CONCLUSION: Impact loads and strength reach interlimb symmetry at 6 months post-HRA. Wearable accelerometers provide useful metrics to distinguish limb asymmetries for recovery monitoring.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Ren R, Spaan J, Jordan A, et al. Novel Use of an Accelerometer to Assess Load Asymmetry Over Time After Hip Resurfacing Arthroplasty. J Arthroplasty. 2023. PMID: 37068566. doi:10.1016/j.arth.2023.04.015

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。