文献速递关节外科创伤骨科

全髋关节翻修术中模块化近端体更换:极少使用且中等成功

Modular Proximal Body Exchange for Re-Revision Total Hip Arthroplasty: Rarely Utilized and Moderately Successful.
PubMed 文献 · J Arthroplasty · 2023-04-20

该研究在1997年至2019年间于8,079例翻修全髋关节置换术中识别出57例模块化近端体更换,平均随访3.4年。模块化近端体更换仅占植入的模块化带槽锥形柄的3%(47/1,375),主要适应证为脱位(53%)和假体周围关节感染部分切除(23%),约三分之一病例需再次翻修。

要点

  • 模块化近端体更换在翻修全髋中极少使用,仅占模块化带槽锥形柄的3%(47/1,375)。
  • 主要适应证为脱位(30/57,53%)和假体周围关节感染部分切除(13/57,23%)。
  • 脱位指征者后续再翻修率为33%(10/30),假体周围关节感染指征者为5/13。

核心结论

  • 模块化带槽锥形柄的近端体更换是不常见的手术,最常用于治疗髋关节脱位或假体周围关节感染。
  • 该手术中等成功,约三分之一病例需要后续再翻修。
  • 该手术常仅通过模块化组件更换完成,但也可有助于复杂的髋臼暴露。

研究设计与样本

  • 回顾性研究,1997年至2019年间在同一机构进行的8,079例翻修全髋关节置换术中,共实施57例模块化近端体更换。
  • 平均随访3.4年(范围0至12.8年)。
  • 证据等级IV。

主要发现

  • 模块化近端体更换在植入的1,375例模块化带槽锥形柄中占47例(3%)。
  • 全部57例模块化近端体更换的适应证为:脱位30例(53%)、假体周围关节感染部分切除13例(23%)、模块化连接部失效8例(14%)、手术暴露4例(7%)、同期行大转子截骨不愈合固定2例(4%)。
  • 末次随访时,脱位指征的模块化近端体更换中10/30例(33%)发生后续再翻修,假体周围关节感染指征者中5/13例发生后续再翻修。
  • 一例模块化连接部在模块化近端体更换后发生断裂。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Modular fluted tapered stems (MFTSs) are commonly used in revision total hip arthroplasty (THA) and provide the option of exchanging the proximal modular portion to address future surgical problems without complete femoral revision. We are unaware of any data documenting the frequencies, indications, and outcomes of modular proximal body exchange in re-revision THA. METHODS: Between 1997 and 2019, we performed 57 modular proximal body exchanges among 8,079 revision THAs at our institution. Indications and outcomes were documented at a mean follow-up of 3.4 years (range, 0 to 12.8). RESULTS: Modular proximal body exchange was performed on 47 of 1,375 (3%) of MFTSs implanted. The indications for all 57 modular proximal body exchanges performed during the study period were dislocation in 30 (53%), partial resection for periprosthetic joint infection (PJI) in 13 (23%), modular junction failure in 8 (14%), surgical exposure in 4 (7%), and concurrently with trochanteric osteotomy nonunion fixation in 2 (4%). At the final follow-up, subsequent re-revisions occurred in 10 of 30 (33%) of modular proximal body exchanges indicated for dislocation and in 5 of 13 of those indicated for PJI. One modular junction subsequently fractured after modular proximal body exchange. CONCLUSION: Modular proximal body exchange of a MFTS is an uncommon procedure most often performed for treatment of hip dislocation or PJI. It is moderately successful with approximately one-third of cases requiring subsequent re-revision. This procedure is often performed with modular component exchange alone, but can also be helpful to facilitate complex acetabular exposure. These data provide useful information to surgeons and patients undergoing this procedure. LEVEL OF EVIDENCE: IV.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Harmer JR, Hadley ML, Trousdale RT, et al. Modular Proximal Body Exchange for Re-Revision Total Hip Arthroplasty: Rarely Utilized and Moderately Successful. J Arthroplasty. 2023. PMID: 37084920. doi:10.1016/j.arth.2023.04.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。