文献速递关节外科

术中直接超声处理植入物与软组织诊断假体周围关节感染

Intraoperative Direct Sonication of Implants and Soft Tissue for the Diagnosis of Periprosthetic Joint Infection.
PubMed 文献 · J Bone Joint Surg Am · 2023-03-31

前瞻性纳入64例需取出植入物的患者(36例假体周围关节感染,28例无菌性失败),比较术中直接超声处理植入物与软组织(无需超声管)联合BACT/ALERT 3D血培养系统与常规滑液培养的诊断效能。直接超声处理液敏感性91.7%高于滑液培养55.6%(p<0.001),特异性82.1%低于滑液培养92.9%。

要点

  • 直接超声处理液敏感性91.7%显著高于常规滑液培养55.6%(p<0.001)。
  • 直接超声处理液特异性82.1%低于滑液培养92.9%。
  • 仅组织直接超声处理敏感性88.9%高于仅植入物直接超声处理75.0%。

核心结论

  • 术中直接超声处理植入物与软组织(无需超声管)联合BACT/ALERT瓶孵育,较常规滑液培养更敏感,可可靠且快速地检出假体周围关节感染常见细菌。

研究设计与样本

  • 前瞻性研究连续纳入需取出植入物的患者,按标准标准分为假体周围关节感染组(36例)和无菌性失败组(28例),共64例。
  • 取出假体组件及邻近软组织在术中于小型金属容器内直接超声处理(无需超声管),超声处理液立即在手术室接种血培养瓶并用BACT/ALERT 3D系统培养;滑液同样用BACT/ALERT 3D系统培养作为对照。

主要发现

  • 直接超声处理液敏感性91.7%,常规滑液培养敏感性55.6%(p<0.001)。
  • 直接超声处理液特异性82.1%,常规滑液培养特异性92.9%。
  • 14例假体周围关节感染经直接超声处理液培养检出而滑液培养未检出。
  • 仅组织直接超声处理敏感性88.9%,仅植入物直接超声处理敏感性75.0%。
  • 金黄色葡萄球菌与凝固酶阴性葡萄球菌的检出时间无显著差异。

关键数值与推荐

  • 直接超声处理液敏感性91.7%,特异性82.1%。
  • 常规滑液培养敏感性55.6%,特异性92.9%。
  • 仅组织直接超声处理敏感性88.9%,仅植入物直接超声处理敏感性75.0%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Sonication is very efficacious for the microbiological diagnosis of periprosthetic joint infection (PJI), but it involves many steps and multiple workplaces and personnel and therefore carries a potential contamination risk. We present an innovative version of the sonication culture method that involves direct sonication of the retrieved implant and soft tissue, without a sonication tube, intraoperatively and incubation using a BACT/ALERT 3D blood culture system to enhance the efficacy of microbiological diagnosis of PJI. METHODS: We performed a prospective study of consecutive patients requiring implant removal and classified them as having PJI or aseptic failure according to standard criteria. The removed prosthetic components and adjacent soft tissue were directly sonicated in a small metal container, without a sonication tube, during the operation. The sonication fluid was immediately incubated in blood culture bottles in the operating room and cultured in the BACT/ALERT 3D blood culture system. The synovial fluid was also cultured in the BACT/ALERT 3D system to serve as a comparison. RESULTS: Of the 64 included patients, 36 had PJI and 28 had aseptic failure. Fluid from direct sonication and conventional synovial fluid showed sensitivities of 91.7% and 55.6% (p < 0.001) and specificities of 82.1% and 92.9%, respectively. Fourteen cases of PJI were detected by culture of fluid from direct sonication but not by culture of synovial fluid. Higher sensitivity was obtained by direct sonication of only tissue than by direct sonication of only the implant (88.9% versus 75.0%). No significant difference in detection time was found between Staphylococcus aureus and coagulase-negative Staphylococcus. CONCLUSIONS: When combined with incubation in BACT/ALERT bottles, direct intraoperative sonication of implants and soft tissues without a sonication tube was more sensitive than conventional synovial fluid culture and could reliably and rapidly detect the bacteria commonly found in PJI. LEVEL OF EVIDENCE: Diagnostic Level II . See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Ji B, Aimaiti A, Wang F, et al. Intraoperative Direct Sonication of Implants and Soft Tissue for the Diagnosis of Periprosthetic Joint Infection. J Bone Joint Surg Am. 2023. PMID: 37071707. doi:10.2106/JBJS.22.00446

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。