伸膝装置断裂仍是棘手问题
该多中心回顾性研究纳入2011至2019年56例全膝关节置换术后伸膝装置断裂行网状补片或全伸膝装置同种异体移植重建的患者,平均随访3.2年,功能成功率为50.0%,36个月重建在位存活率为75.0%,两种重建方法间存活率和成功率相似,并发症和再手术率高。
要点
- 全膝关节置换术后伸膝装置断裂重建的平均3.2年随访功能成功率为50.0%(28/56)。
- 36个月重建在位存活率为75.0%(42/58),两种重建方法间存活率和成功率相似。
- 全因再手术率为42.9%(24/56),翻修重建率为14.3%(8/56),膝上截肢或模块化融合率为10.7%(6/56)。
核心结论
- 该多中心研究显示网状补片或同种异体移植伸膝装置重建在3.2年时功能成功率中等,并发症和再手术率高,无论采用何种重建技术,全膝关节置换术后伸膝装置断裂仍是棘手问题。
研究设计与样本
- 回顾性多中心研究,纳入2011至2019年在两家三级医疗中心因全膝关节置换术后伸膝装置断裂接受网状补片或全伸膝装置同种异体移植重建、至少随访2年的患者,共56例伸膝装置重建(49例患者)。
- 功能失败定义为伸膝滞后>30度、截肢或融合,以及翻修伸膝装置重建;采用Kaplan-Meier曲线评估存活率,采用逻辑回归确定成功因素。
主要发现
- 56例伸膝装置重建中,50.0%(28/56)在平均随访3.2年(范围0.2至7.4年)时功能成功。
- 36个月时重建在位存活率为75.0%(42/58)。
- 功能失败的伸膝装置重建中,50.0%(14/28)在末次随访时重建仍在位。
- 成功组与失败组的平均伸膝滞后分别为5.4度和71.0度(P = .01),平均膝关节损伤与骨关节炎结局评分-关节置换评分分别为67.1分和48.8分(P = .01)。
- 25例成功者中64.0%(16/25)和19例失败者中1例获得高于全膝关节置换术最低患者可接受症状状态的膝关节损伤与骨关节炎结局评分-关节置换评分;两种重建方法间存活率和成功率相似(P = .86;P = .76)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Extensor mechanism disruption (EMD) following total knee arthroplasty (TKA) is a devastating problem commonly treated with allograft or synthetic reconstruction. Understanding of reconstruction success rates and patient recorded outcomes is lacking. METHODS: Patients who have an EMD after TKA undergoing mesh or whole-extensor allograft reconstruction between 2011 and 2019, with minimum 2-year follow-up were reviewed at two tertiary care centers. Functional failure was defined as extensor lag >30 degrees, amputation, or fusion, as well as revision extensor mechanism reconstruction (EMR). Survivorship was assessed using Kaplan-Meier curves, and factors for success were determined with logistic regressions. RESULTS: Of fifty-six EMRs (49 patients), 50.0% (28/56) were functionally successful at 3.2 years of mean follow-up (range, 0.2 to 7.4). In situ survivorship of the reconstructions at 36 months was 75.0% (42 of 58). There were 50.0% (14 of 28) of functionally failed EMRs that retained their reconstruction at last follow-up. Mean extensor lag among successes and failures was 5.4 and 71.0° (P = .01), respectively. Mean Knee Injury and Osteoarthritis Outcome Score, Joint Replacement scores were 67.1 and 48.8 among successes and failures (P = .01). There were 64.0% (16 of 25) of successes and 1 of 19 failures that obtained a Knee Injury and Osteoarthritis Outcome Score, Joint Replacement score above the minimum patient-acceptable symptom state for TKA. Survivorship and success rates were similar between reconstruction methods (P = .86; P = .76). All-cause mortality was 8.2% (4 of 49), each with EMR failure prior to death. All-cause reoperation rate was 42.9% (24 of 56), with a 14.3% (8 of 56) rate of revision EMR and 10.7% (6 of 56) rate of above-knee-amputation or modular fusion. CONCLUSIONS: This multicenter investigation of mesh or allograft EMR demonstrated modest functional success at 3.2 years. Complication and reoperation rates were high, regardless of EMR technique. Therefore, EMD after TKA remains problematic.
引用
- Anderson JT, McLeod CB, Anderson LA, et al. Extensor Mechanism Disruption Remains a Challenging Problem. J Arthroplasty. 2023. PMID: 37001620. doi:10.1016/j.arth.2023.03.067