文献速递脊柱外科骨质疏松与代谢性骨病

18F-氟化钠正电子发射断层扫描/计算机断层扫描在测量衰老脊柱代谢活性中的效用:对骨质疏松症的意义

The Utility of 18 F-NaF-Positron Emission Tomography/Computed Tomography in Measuring the Metabolic Activity of the Aging Spine : Implications for Osteoporosis.
PubMed 文献 · Spine (Phila Pa 1976) · 2023-03-24

横断面观察性研究纳入88名健康志愿者,探讨18F-氟化钠PET/CT能否监测脊柱随年龄增长的骨转换下降;女性NaF摄取与年龄呈显著负相关,男性相关性较弱,且NaF摄取随采集时间增加。

要点

  • 女性腰椎NaF SUVmean与年龄显著负相关(P<0.0001,r=-0.59)。
  • 男性腰椎NaF SUVmean与年龄相关性较弱但显著(P=0.03,r=-0.32)。
  • NaF摄取随注射后采集时间从45至90分钟及90至180分钟增加10%至15%。

核心结论

  • NaF-PET/CT可检测到随年龄增长而下降的椎体骨转换,尤其在女性中。
  • 注射示踪剂后NaF摄取随PET采集时间增加,监测疾病发展和治疗效果的随访研究须考虑此因素。

研究设计与样本

  • 横断面观察性研究,纳入88名健康志愿者(女性43名,男性45名;平均年龄44.6岁)。
  • 在注射后90分钟采集图像,以L1至L4椎体骨小梁区域为感兴趣区计算平均标准化摄取值(SUVmean)和平均Hounsfield单位(HU)值。
  • 采用Wilson/Brown法生成受试者工作特征曲线及曲线下面积,评估NaF摄取(SUVmean)预测以HU阈值定义的骨质疏松的价值。
  • 采用Spearman相关检验分析整体SUVmean、平均HU值与年龄的相关性。

主要发现

  • 女性NaF SUVmean与年龄呈显著负相关(P<0.0001,r=-0.59)。
  • 男性NaF SUVmean与年龄相关性较弱但显著(P=0.03,r=-0.32)。
  • 仅女性在所有采集时间点NaF摄取与年龄显著相关。
  • 两性NaF摄取随采集时间从45至90分钟及从90至180分钟增加10%至15%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: Cross-sectional; observational. OBJECTIVES: To determine whether sodium fluoride (NaF) positron emission tomography/computed tomography (PET/CT) can be used to monitor decreased bone turnover with aging in the spine. BACKGROUND: Osteoporosis is characterized by structural changes in the bone such as decreased bone mineral density leading to an increased risk for fractures. An imaging modality capable of identifying molecular changes that precede these structural changes could be critical for the early diagnosis and monitoring of osteoporosis and other metabolic bone disorders. MATERIALS AND METHODS: The potential of 18 F-sodium fluoride (NaF)-PET/CT in detecting changes in bone turnover associated with aging was examined in the lumbar spine of 88 healthy volunteers (43 females, 45 males; mean age 44.6 yr). Regions of interest equal to the trabecular body of the L1 to L4 vertebrae were used to calculate the mean standardized uptake value (SUVmean) and average Hounsfield unit (HU) values. Receiver-operating characteristic curve analysis with an area under the curve using the Wilson/Brown method was generated to assess the value of NaF uptake (SUVmean) in predicting osteoporosis as defined by HU-threshold values. To determine the correlation among global SUVmean, mean HU values, and age, the Spearman correlation test was performed on images acquired at 90 minutes postinjection. RESULTS: There was a significant negative correlation between NaF SUVmean and age in females ( P < 0.0001, r = -0.59), and a weaker, but also significant correlation in males ( P = 0.03, r = -0.32). In females only, there was a significant correlation between NaF uptake and age at all acquisition time points. Measured NaF uptake increased by 10% to 15% with acquisition time in both sexes, from 45 to 90 minutes and from 90 to 180 minutes. CONCLUSIONS: NaF-PET/CT detects decreased vertebral bone turnover with aging, particularly in females. Measured NaF uptake increased with PET acquisition time after tracer injection, which must be considered in follow-up studies monitoring disease development and treatment effects.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Park PSU, Resto DA, Khurana N, et al. The Utility of 18 F-NaF-Positron Emission Tomography/Computed Tomography in Measuring the Metabolic Activity of the Aging Spine : Implications for Osteoporosis. Spine (Phila Pa 1976). 2023. PMID: 36972138. doi:10.1097/BRS.0000000000004640

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。