文献速递关节外科创伤骨科

经皮股骨颈头开窗改良灯泡技术联合压实人工骨移植治疗塌陷前股骨头坏死的疗效

Efficacy of Modified Lightbulb Technique by Percutaneous Femoral Neck-Head Fenestration Combined With Compacted Artificial Bone Graft for Treating Precollapse Osteonecrosis of the Femoral Head.
PubMed 文献 · J Arthroplasty · 2023-03-14

回顾性研究纳入73例国际骨循环研究协会(ARCO)Ⅱ期股骨头坏死患者(81髋),比较经皮股骨颈头开窗改良灯泡技术下自体骨与人工骨(脱钙骨基质/硫酸钙,DBM/CaS)移植的临床结局,平均随访61个月,两组Harris评分、影像学进展率、临床成功率及生存分析均无显著差异。

要点

  • DBM/CaS组末次随访平均Harris评分80分,自体骨组76分(P=.751)。
  • DBM/CaS组影像学进展率29.9%,自体骨组37.5%(P=.43)。
  • DBM/CaS组73.2%、自体骨组75%避免全髋关节置换(P=.85)。

核心结论

  • 经皮股骨颈头开窗联合人工骨(DBM/CaS)移植在防止股骨头塌陷和挽救全髋关节置换方面与自体骨移植具有相当的临床结局,平均随访61个月。

研究设计与样本

  • 回顾性研究纳入73例ARCO Ⅱ期股骨头坏死患者(81髋),平均随访61个月(范围52至74个月),其中40髋接受自体骨移植、41髋接受DBM/CaS移植,均经经皮股骨颈头开窗改良灯泡技术完成。

主要发现

  • 末次随访DBM/CaS组平均Harris评分80分(范围63至92),自体骨组76分(范围69至91),P=.751。
  • DBM/CaS组影像学进展率29.9%,自体骨组37.5%,P=.43。
  • DBM/CaS组73.2%患者、自体骨组75%患者避免全髋关节置换,P=.85。
  • 股骨头保护生存分析显示两组结局相似(P>.05)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Whether artificial bone provides comparable outcomes to autogenous bone has not been determined for osteonecrosis of the femoral head (ONFH). This study was conducted to compare the clinical outcomes of autogenous and artificial bone grafting (demineralized bone matrix/calcium sulfate [DBM/CaS]) through a modified lightbulb technique by percutaneous femoral neck-head fenestration for treating precollapse ONFH. METHODS: A total of 73 Association Research Circulation Osseous Stage Ⅱ ONFH patients (81 hips) who had a mean follow-up of 61 months (range, 52 to 74) were included in this retrospective study. Among them were 40 hips treated with autogenous bone and 41 hips treated with DBM/CaS grafting through the percutaneous femoral neck-head fenestration. The Harris scores, radiographic progressions, clinical success rates, and survival analyses were analyzed. RESULTS: At final follow-up, the mean Harris score was 80 points (range, 63 to 92) in the DBM/CaS group and 76 points (range, 69 to 91) in the autogenous bone group (P = .751). The radiographic progression rate was 29.9% in the DBM/CaS group, without significant difference from the autogenous bone group, which was 37.5% (P = .43). About 73.2% of patients in the DBM/CaS group and 75% in the autologous bone group avoided a total hip arthroplasty (P = .85). Survival analysis for femoral head protection revealed similar outcomes between the 2 groups (P > .05). CONCLUSION: Percutaneous femoral neck-head fenestration combined with artificial bone (DBM/CaS) grafting had comparable clinical outcomes to autologous bone grafting on preventing femoral head collapse and rescuing THA at a mean of 61-month follow-up for treating early ONFH.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Li D, Sun S, Yang Z, et al. Efficacy of Modified Lightbulb Technique by Percutaneous Femoral Neck-Head Fenestration Combined With Compacted Artificial Bone Graft for Treating Precollapse Osteonecrosis of the Femoral Head. J Arthroplasty. 2023. PMID: 36924857. doi:10.1016/j.arth.2023.03.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。