文献速递关节外科

标准骨盆前后位X线片上腿长差异的变异性:一项深度学习测量分析

Leg-Length Discrepancy Variability on Standard Anteroposterior Pelvis Radiographs: An Analysis Using Deep Learning Measurements.
PubMed 文献 · J Arthroplasty · 2023-03-09

本研究利用深度学习算法在骨关节炎倡议队列的骨盆前后位X线片上自动测量腿长差异(LLD),比较六种解剖标志组合的测量结果。算法在独立队列中验证的组内相关系数(ICC)为0.73-0.98,对3,689例患者完成22,134次测量耗时133分钟。以泪滴和股骨小转子为标准方法时,仅泪滴和股骨大转子组合具有可接受一致性(ICC=0.72),六种方法间无组合ICC>0.90,提示基于不同骨盆/股骨标志的LLD测量存在显著变异,需要标准化。

要点

  • 深度学习算法可在133分钟内完成3,689例患者的22,134次LLD测量。
  • 以泪滴和股骨小转子为标准方法时,仅泪滴和股骨大转子组合ICC=0.72达到可接受一致性。
  • 六种LLD测量方法间无组合ICC>0.90,仅13%组合ICC>0.75,53%组合ICC<0.50。

核心结论

  • 利用深度学习在大型患者队列中自动测量LLD,发现基于骨盆/股骨标志选择的LLD存在相当大的变异,强调研究和手术规划中标志标准化的必要性。

研究设计与样本

  • 纳入骨关节炎倡议(Osteoarthritis Initiative)中有基线骨盆前后位X线片的患者,创建深度学习算法识别LLD相关标志(泪滴、闭孔、坐骨结节、股骨大转子和小转子)并使用六种标志组合测量LLD,算法在独立队列中验证后应用于整个队列自动测量。

主要发现

  • 深度学习算法在独立队列中对所有六种LLD方法验证的ICC为0.73-0.98。
  • 对3,689例患者的图像(22,134次LLD测量)在133分钟内完成测量。
  • 以泪滴和股骨小转子为标准LLD方法时,仅使用泪滴和股骨大转子测量LLD具有可接受一致性(ICC=0.72)。
  • 比较所有六种LLD方法的一致性,无组合ICC>0.90;仅两种(13%)组合ICC>0.75,八种(53%)组合ICC差(<0.50)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Leg-length discrepancy (LLD) is a critical factor in component selection and placement for total hip arthroplasty. However, LLD radiographic measurements are subject to variation based on the femoral/pelvic landmarks chosen. This study leveraged deep learning (DL) to automate LLD measurements on pelvis radiographs and compared LLD based on several anatomically distinct landmarks. METHODS: Patients who had baseline anteroposterior pelvis radiographs from the Osteoarthritis Initiative were included. A DL algorithm was created to identify LLD-relevant landmarks (ie, teardrop (TD), obturator foramen, ischial tuberosity, greater and lesser trochanters) and measure LLD accurately using six landmark combinations. The algorithm was then applied to automate LLD measurements in the entire cohort of patients. Interclass correlation coefficients (ICC) were calculated to assess agreement between different LLD methods. RESULTS: The DL algorithm measurements were first validated in an independent cohort for all six LLD methods (ICC = 0.73-0.98). Images from 3,689 patients (22,134 LLD measurements) were measured in 133 minutes. When using the TD and lesser trochanter landmarks as the standard LLD method, only measuring LLD using the TD and greater trochanter conferred acceptable agreement (ICC = 0.72). When comparing all six LLD methods for agreement, no combination had an ICC>0.90. Only two (13%) combinations had an ICC>0.75 and eight (53%) combinations had a poor ICC (<0.50). CONCLUSION: We leveraged DL to automate LLD measurements in a large patient cohort and found considerable variation in LLD based on the pelvic/femoral landmark selection. This emphasizes the need for the standardization of landmarks for both research and surgical planning.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Jang SJ, Kunze KN, Bornes TD, et al. Leg-Length Discrepancy Variability on Standard Anteroposterior Pelvis Radiographs: An Analysis Using Deep Learning Measurements. J Arthroplasty. 2023. PMID: 36898486. doi:10.1016/j.arth.2023.03.006

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。