机器人辅助全髋关节置换术前所需CT可识别既往未诊断的骨质疏松并指导股骨固定策略
回顾性图表回顾研究纳入78例机器人辅助全髋关节置换术(raTHA)前行CTXA的患者(组1),并按年龄和性别匹配78例有术前髋部CT但未行CTXA分析的患者(组2)。组1术前股骨骨密度(BMD)获取率100%(CTXA),组2为43.6%(DXA);CTXA在组1中识别出13例骨量减少和8例骨质疏松且无术前DXA数据者。组1骨水泥柄固定使用率高于组2(28.2% vs 14.3%,p=0.030),且所有诊断为骨质疏松者无论采用DXA或CTXA均使用骨水泥柄固定;本小型研究中未影响短期假体周围骨折风险。
要点
- raTHA术前常规髋部CT可行CTXA评估股骨骨密度,指导股骨固定策略。
- CTXA系统性评估较常规临床 care 提高骨量减少和骨质疏松的识别率。
- 组1骨水泥柄固定使用率28.2% vs 组2 14.3%(p=0.030),所有骨质疏松诊断者均用骨水泥柄。
核心结论
- raTHA术前常规获得的髋部CT扫描可确定骨健康,从而指导股骨固定策略。
- 系统性术前CTXA评估增加了骨量减少和骨质疏松的识别,并较常规临床 care 促进了骨水泥股骨固定的使用增加;但本小型研究中未影响短期假体周围骨折风险。
研究设计与样本
- 回顾性图表回顾单外科医生数据库,识别78例在raTHA术前行CTXA的患者(组1),并按年龄和性别匹配78例有术前髋部CT但未行CTXA分析的raTHA患者(组2)。
主要发现
- 组1术前股骨BMD获取率为100%(CTXA),组2为43.6%(DXA)。
- CTXA分析在组1术前识别出13例骨量减少和8例骨质疏松患者,这些患者无可用术前DXA数据。
- 骨水泥柄固定使用率组1为28.2%,组2为14.3%(p=0.030),组1高于组2。
- 所有诊断为骨质疏松的病例无论采用DXA或CTXA技术均使用骨水泥柄固定。
临床怎么用
- 原文结论指出raTHA术前常规髋部CT可确定骨健康并指导股骨固定策略;系统性CTXA评估增加了骨量减少和骨质疏松的识别并促进骨水泥股骨固定使用增加,但本小型研究中未影响短期假体周围骨折风险。
局限性
- 原文自述本小型研究中未影响短期假体周围骨折风险。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Osteoporosis can determine surgical strategy for total hip arthroplasty (THA), and perioperative fracture risk. The aims of this study were to use hip CT to measure femoral bone mineral density (BMD) using CT X-ray absorptiometry (CTXA), determine if systematic evaluation of preoperative femoral BMD with CTXA would improve identification of osteopenia and osteoporosis compared with available preoperative dual-energy X-ray absorptiometry (DXA) analysis, and determine if improved recognition of low BMD would affect the use of cemented stem fixation. Retrospective chart review of a single-surgeon database identified 78 patients with CTXA performed prior to robotic-assisted THA (raTHA) (Group 1). Group 1 was age- and sex-matched to 78 raTHAs that had a preoperative hip CT but did not have CTXA analysis (Group 2). Clinical demographics, femoral fixation method, CTXA, and DXA data were recorded. Demographic data were similar for both groups. Preoperative femoral BMD was available for 100% of Group 1 patients (CTXA) and 43.6% of Group 2 patients (DXA). CTXA analysis for all Group 1 patients preoperatively identified 13 osteopenic and eight osteoporotic patients for whom there were no available preoperative DXA data. Cemented stem fixation was used with higher frequency in Group 1 versus Group 2 (28.2% vs 14.3%, respectively; p = 0.030), and in all cases where osteoporosis was diagnosed, irrespective of technique (DXA or CTXA). Preoperative hip CT scans which are routinely obtained prior to raTHA can determine bone health, and thus guide femoral fixation strategy. Systematic preoperative evaluation with CTXA resulted in increased recognition of osteopenia and osteoporosis, and contributed to increased use of cemented femoral fixation compared with routine clinical care; in this small study, however, it did not impact short-term periprosthetic fracture risk.
引用
- Bukowski BR, Sandhu KP, Bernatz JT, et al. CT required to perform robotic-assisted total hip arthroplasty can identify previously undiagnosed osteoporosis and guide femoral fixation strategy. Bone Joint J. 2023. PMID: 36854330. doi:10.1302/0301-620X.105B3.BJJ-2022-0870.R1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。