套叠式同种异体骨假体复合物在全髋关节置换术中的应用:广泛股骨骨缺损的挽救性手术
该回顾性单中心研究纳入1994至2015年间46例使用近端股骨套叠式同种异体骨假体复合物(APC)行翻修全髋关节置换术(THA)的病例,平均随访5-10年。10年时总体患者生存率58%、无再手术生存率76%、假体复合物生存率95%,再手术率20%(n=9),仅2例复合物需切除。影像学显示股骨柄松动0例、APC-宿主界面愈合率86%、部分异体骨吸收征象23%、大转子愈合率54%,术后Harris髋关节评分平均71分。结论认为套叠式APC技术操作要求高,但能为翻修THA中大型近端股骨骨缺损提供可靠的机械固定,假体复合物生存率优异、再手术率可接受且临床结果良好。
要点
- 10年假体复合物生存率95%,无再手术生存率76%,总体患者生存率58%。
- 再手术率20%(n=9),仅2例复合物需切除;影像学股骨柄松动0例。
- APC-宿主界面愈合率86%,异体骨吸收征象23%,大转子愈合率54%;术后Harris评分平均71分。
核心结论
- 套叠式APC技术操作要求高,但能为翻修THA中大型近端股骨骨缺损的重建提供可靠的机械固定,假体复合物生存率优异、再手术率可接受且临床结果良好。
研究设计与样本
- 1994年至2015年间在单中心回顾性审查了46例使用近端股骨套叠式APC的翻修THA。
- 采用Kaplan-Meier法计算总体生存率、无再手术生存率和假体复合物生存率,并进行影像学分析评估组件松动、APC-宿主界面愈合及异体骨吸收。
主要发现
- 10年时总体患者生存率为58%,无再手术生存率为76%,假体复合物生存率为95%。
- 20%(n=9)进行了再手术,仅2例假体复合物需要切除。
- 末次随访影像学分析显示无股骨柄放射学松动病例,APC-宿主部位愈合率为86%,23%有部分异体骨吸收征象,大转子愈合率为54%。
- 术后Harris髋关节评分平均为71分(范围46-100)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Allograft prosthetic composites (APCs) have been used to perform revision total hip arthroplasty (THA) for massive femoral bone loss or deformity. Intussusception, or "telescoping", APC techniques have been proposed to enhance the contact area of this interface and provide superior mechanical fixation over conventional methods. The purpose of this study is to present to our knowledge, the largest series of telescoping APC THAs, along with surgical technique details and midterm (average 5-10 years) clinical results. METHODS: Between 1994 and 2015, 46 revision THAs performed with proximal femoral telescoping APCs were retrospectively reviewed at a single institution. Overall survival, reoperation-free survival, and construct survival rates were calculated via Kaplan-Meier methods. In addition, radiographic analyses were performed to evaluate for component loosening, union at the APC-host interface, and resorption of the allograft. RESULTS: At 10 years, the overall patient survival was 58%, reoperation-free survival was 76%, and construct survival was 95%. Reoperation was performed in 20% (n = 9) and only 2 constructs required resection. Radiographic analyses performed at latest follow-up revealed no instances of radiographic femoral stem loosening, an 86% union rate at the APC-host site, 23% with signs of some allograft resorption, and a 54% trochanteric union. The mean postoperative Harris hip score was 71 points (range, 46-100). CONCLUSION: Telescoping APCs are technically demanding, but provide reliable mechanical fixation for the reconstructing of large proximal femoral bone deficits in revision THA with excellent construct survivorship, acceptable reoperation rates, and good clinical outcomes. LEVEL OF EVIDENCE: IV.
引用
- Hadley ML, Shirley MB, Pulido LF, et al. Intussusception Allograft Prosthetic Composites in Total Hip Arthroplasty: A Salvage Operation for Extensive Femoral Bone Loss. J Arthroplasty. 2023. PMID: 36940757. doi:10.1016/j.arth.2023.03.038
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。