后路全髋关节置换术采用单块双动假体且不实施传统后髋保护措施:580髋系列中仅1例脱位
研究纳入575例患者共580髋,采用微后路单块双动假体全髋关节置换且不使用传统后髋保护措施,杯位置依据患者特异性解剖标志而非传统术中 radiographic 外展与前倾目标,稳定性通过术中显著动态活动度测试评估。平均外展48.4°、平均前倾24.7°,患者报告结局各领域均改善,7例(1.2%)再手术,仅1例(0.2%)脱位。作者认为后路髋外科医生可考虑使用单块双动假体并避免传统后髋保护措施。
要点
- 580髋微后路单块双动假体全髋置换,不使用传统后髋保护措施。
- 仅1例(0.2%)脱位,该患者有脊髓损伤和Charcot关节病术前史。
- 患者报告结局测量信息系统各领域评分从术前至末次术后随访均改善。
核心结论
- 作者认为后路髋外科医生可考虑使用单块双动假体并避免传统后髋保护措施,以实现早期髋稳定、极低脱位率和高患者满意度评分。
研究设计与样本
- 连续580髋(575例患者)接受使用单块双动假体和微后路入路的全髋关节置换术。
- 术中杯位置不依赖传统术中放射学外展和前倾目标,而使用患者特异性解剖标志(前髋臼缘及可见时的髋臼横韧带)设定杯位置。
- 稳定性通过术中显著的动态活动度测试评估。
- 患者平均年龄64岁(范围21至94岁),53.7%为女性。
主要发现
- 平均外展48.4°(范围29°至68°),平均前倾24.7°(范围-1°至51°)。
- 患者报告结局测量信息系统评分从术前至末次术后随访在每个测量领域均改善。
- 7例(1.2%)患者需要再手术,平均再手术时间1.3个月(范围1至176天)。
- 仅1例(0.2%)患者脱位,该患者有脊髓损伤和Charcot关节病术前史。
临床怎么用
- 作者认为后路髋外科医生可考虑使用单块双动假体并避免传统后髋保护措施,以实现早期髋稳定、极低脱位率和高患者满意度评分。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Instability remains a devastating complication following total hip arthroplasty. Here we describe a mini-posterior approach with a monoblock dual-mobility implant without "traditional posterior hip precautions" yielding excellent results. METHODS: There were 580 consecutive hips in 575 patients who underwent total hip arthroplasty utilizing a monoblock dual-mobility implant and a mini-posterior approach. With this technique, the acetabular component positioning does not rely on tradition intra-operative radiographic abduction and anteversion goals but rather uses patient-specific anatomic landmarks (anterior acetabular rim and, when visible, the transverse acetabular ligament) to set cup position; stability is assessed with a significant, dynamic intra-operative test of range of motion. Patients' mean age was 64 years (range, 21 to 94), and 53.7% were women. RESULTS: Mean abduction was 48.4° (range, 29° to 68°) and mean anteversion was 24.7° (range, -1° to 51°). Patient Reported Outcomes Measurement Information System scores improved in every measured domain from preoperative to final postoperative visit. There were seven (1.2%) patients who required reoperation, with mean time to reoperation of 1.3 months (range, one to 176 days). Only one patient (0.2%) who had a preoperative history of spinal cord injury and Charcot arthropathy dislocated. CONCLUSION: A posterior approach hip surgeon may want to consider using a monoblock dual-mobility construct and avoidance of traditional posterior hip precautions to achieve early hip stability with an extremely low dislocation rate and high patient satisfaction scores.
引用
- Gibian JT, Hong TS, Nunley RM, et al. Posterior Approach Total Hip Arthroplasty Utilizing a Monoblock Dual-Mobility Construct Without Posterior Hip Precautions: A Series of 580 Hips With One Dislocation. J Arthroplasty. 2023. PMID: 36933682. doi:10.1016/j.arth.2023.03.027
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。