现代一体式与模块式钛制带槽锥形股骨柄之间的下沉无差异

No Difference in Subsidence Between Modern Monoblock and Modular Titanium Fluted Tapered Femoral Stems.
PubMed 文献 · J Arthroplasty · 2023-03-23

该单中心回顾性研究比较了271例全髋关节置换术中使用的3种现代钛制带槽锥形股骨柄(1种一体式,n=91;2种模块式,n=90和n=90)的下沉情况。结果显示,各柄在总体下沉(P=0.191)及下沉>5毫米的发生率(P=0.126)上均无统计学显著差异;双皮质接触增加与下沉减少相关(P=0.004);术中影像使用率为46.5%(126/271),与双皮质接触(P=0.673)或下沉(P=0.521)均不相关。作者结论认为3种柄均高度成功且下沉率低,术者应选择其认为最临床适用的柄。

要点

  • 3种现代钛制带槽锥形股骨柄(1种一体式、2种模块式)在总体下沉及下沉>5毫米发生率上无统计学显著差异。
  • 双皮质接触增加与下沉减少相关(P=0.004)。
  • 术中影像使用率为46.5%(126/271),与双皮质接触(P=0.673)或下沉(P=0.521)均不相关。

核心结论

  • 3种现代钛制带槽锥形股骨柄均高度成功且下沉率低,无论模块式或一体式设计。
  • 作者认为术者应选择其认为最临床适用的柄。

研究设计与样本

  • 单中心回顾性综述,纳入271例使用现代钛制带槽锥形股骨柄的全髋关节置换术。
  • 纳入3种柄设计:1种一体式钛制带槽锥形股骨柄(n=91)和2种模块式钛制带槽锥形股骨柄(n=90;n=90)。
  • 记录患者人口学资料、Paprosky股骨骨丢失分类、双皮质接触、术中影像使用情况及柄下沉(术后初始X线片与末次随访X线片比较,至少3个月)。

主要发现

  • 各柄间总体下沉无统计学显著差异(P=0.191)。
  • 各柄间下沉>5毫米的发生率无统计学显著差异(P=0.126)。
  • 基于股骨骨丢失分级的亚组分析显示各柄间下沉无差异。
  • 双皮质接触增加与下沉减少相关(P=0.004)。
  • 术中影像使用率为46.5%(126/271),与双皮质接触(P=0.673)或下沉(P=0.521)均不相关。

临床怎么用

  • 作者认为术者应选择其认为最临床适用的柄。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Subsidence remains a concern when utilizing tapered fluted titanium (TFT) femoral stems and may lead to leg length discrepancy, impingement, instability, and failure to obtain osseointegration. This study aims to compare stem subsidence across 3 modern TFT stems. Our secondary aim was to investigate the influence of bicortical contact or "scratch fit" on subsidence, as well as the role of intraoperative imaging in maximizing bicortical contact and preventing stem subsidence. METHODS: A retrospective review of 271 hip arthroplasties utilizing modern TFT stems at a single institution was performed. Three stem designs were included in the analysis: 1 monoblock TFT stem (n = 91) and 2 modular TFT stems (n = 90; n = 90). Patient demographics, Paprosky femoral bone loss classification, bicortical contact, utilization of intraoperative imaging, and stem subsidence (comparison of initial postoperative radiograph to the latest follow-up radiograph-minimum 3 months) were recorded. RESULTS: There was no statistically significant difference in overall subsidence (P = .191) or the incidence of subsidence >5 millimeters between stems (P = .126). Subgroup analysis based on femoral bone loss grading showed no difference in subsidence between stems. Increased bicortical contact was associated with reduced subsidence (P = .004). Intraoperative imaging was used in 46.5% (126 of 271) of cases; this was not correlated with bicortical contact (P = .673) or subsidence (P = .521). CONCLUSION: All 3 modern TFT stems were highly successful and associated with low rates of subsidence, regardless of modular or monoblock design. Surgeons should select the stem that they feel is most clinically appropriate.