因髌骨组件失败而翻修髌股关节置换术时结局受损
该回顾性研究将2000至2021年间20例无菌性髌股关节置换术(PFA)转为全膝关节置换术(TKA)的病例与60例原发TKA匹配比较,发现因髌骨失败(骨折、组件松动)翻修的病例术后屈曲度更差、僵硬并发症更多,髌骨组件失败者患者报告结局也更差;作者建议术者避免过薄的髌骨切除和广泛外侧松解。
要点
- 因髌骨失败翻修的PFA转TKA病例术后屈曲度115° vs 原发TKA 127°(P=0.023),僵硬并发症40% vs 0%(P=0.046)。
- 因髌骨组件失败翻修的病例PROMIS身体功能32 vs 45(P=0.0046)、身体健康42 vs 49(P=0.0258)、疼痛评分45 vs 24(P=0.0465)均更差。
- 作者建议术者避免过薄的髌骨切除和广泛外侧松解以减少髌骨失败。
核心结论
- PFA转TKA的结局与原发TKA相似,但髌骨组件失败的患者术后活动度和患者报告结局更差。
- 作者建议术者避免过薄的髌骨切除和广泛外侧松解以减少髌骨失败。
研究设计与样本
- 回顾性病历审查,纳入2000至2021年间无菌性PFA转TKA病例,按患者性别、体质指数和美国麻醉医师学会评分匹配原发TKA队列。
- 共20例PFA转TKA符合纳入标准,并与60例原发TKA匹配。
主要发现
- 翻修原因:关节炎进展7例,股骨组件失败5例,髌骨组件失败5例,髌骨轨迹不良3例。
- 因髌骨失败(骨折、组件松动)翻修的病例术后屈曲度115° vs 原发TKA 127°(P=0.023),僵硬并发症40% vs 0%(P=0.046)。
- 因髌骨组件失败翻修的病例PROMIS身体功能32 vs 45(P=0.0046)、身体健康42 vs 49(P=0.0258)、疼痛评分45 vs 24(P=0.0465)。
- 感染率、麻醉下手法松解率或再手术率无差异。
临床怎么用
- 作者建议术者避免过薄的髌骨切除和广泛外侧松解以减少髌骨失败。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Outcomes of patellofemoral arthroplasty (PFA) to total knee arthroplasty (TKA) conversion are reported to be similar to primary cases. The purpose of this study was to determine whether the cause for conversion from PFA to TKA correlated to outcomes when compared to a matched cohort. METHODS: A retrospective chart review was performed to identify aseptic PFA to TKA conversions between 2000 and 2021. A cohort of primary TKAs was matched by patient sex, body mass index, and American Society of Anesthesiology score. Clinical outcomes, including range of motion, complication rates, and patient reported outcomes measurement information systems scores, were compared. Chi-squared, Fisher's Exact, and t-tests were performed. There were 20 PFA to TKA conversions that met inclusion criteria and were matched to 60 primary cases. RESULTS: There were 7 cases revised for arthritis progression, 5 for femoral component failure, 5 for patellar component failure, and 3 for patellar maltracking. PFA to TKA conversions for patellar failure (fracture, component loosening) had worse postoperative flexion (115 versus 127°, P = .023) and more complications of stiffness (40 versus 0%, P = .046) than primary TKAs. Conversions for failed patellar components had worse patient reported outcomes measurement information systems physical function (32 versus 45, P = .0046), physical health (42 versus 49, P = .0258), and pain scores (45 versus 24, P = .0465). No differences were found in rates of infection, manipulations under anesthesia, or reoperations. CONCLUSION: PFA to TKA conversion outcomes were similar to primary TKA, except in patients who had failed patellar components and demonstrated worse postoperative range of motion and patient-reported outcomes. Surgeons should avoid thin patellar resections and extensive lateral releases to minimize patellar failures.
引用
- Treu EA, Frandsen JJ, Al Saidi NN, et al. Outcomes are Compromised When Revising Patellofemoral Arthroplasties for Patellar Component Failures. J Arthroplasty. 2023. PMID: 36889525. doi:10.1016/j.arth.2023.02.083
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。