骨软骨同种异体移植重建失败后行转换全膝关节置换术:功能表现相似但患者满意度较低
该回顾性研究评估25例(26膝)骨软骨同种异体移植早期失败后行转换全膝关节置换术(cTKA)的手术技术与患者报告结局,并与倾向性匹配的50例(52膝)原发性全膝关节置换术(pTKA)比较。两组其他患者报告结局测量无显著差异,但cTKA组平均满意度较低(4.4±1.1 vs 4.8±0.5分,P=0.02)。cTKA术后高满意度与较高的术后KOOS-JR评分相关(84.4 vs 64.2分,P=0.01)。
要点
- cTKA术后功能改善与pTKA相似,但患者满意度较低(4.4±1.1 vs 4.8±0.5分,P=0.02)。
- cTKA高满意度与较高术后KOOS-JR相关(84.4 vs 64.2分,P=0.01)。
- cTKA中46.1%使用翻修假体,15.4%需加强块,11.5%使用内翻-外翻限制型假体。
核心结论
- 骨软骨同种异体移植失败后的cTKA术后改善程度与pTKA相似,但患者报告的满意度较低,且较低满意度与较低的术后KOOS-JR评分相关。
研究设计与样本
- 回顾性评估25例连续cTKA患者(26膝),并与按年龄和体重指数倾向性匹配的50例因骨关节炎行pTKA患者(52膝)比较。
主要发现
- cTKA组12例(46.1%)使用翻修假体,4例(15.4%)需加强块,3例(11.5%)使用内翻-外翻限制型假体。
- cTKA组平均患者报告满意度为4.4±1.1分,pTKA组为4.8±0.5分(P=0.02)。
- cTKA高满意度组术后KOOS-JR为84.4分,低满意度组为64.2分(P=0.01)。
- cTKA高满意度组UCLA活动评分为6.9分,低满意度组为5.7分(P=0.08)。
- 两组手法松解率分别为cTKA组15.3%与pTKA组7.6%(P=0.42),pTKA组1例(1.9%)因早期术后感染接受治疗。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: This study presents surgical techniques used in conversion total knee arthroplasty (cTKA) following early failure of large osteochondral allograft joint replacement and compares postoperative patient reported outcomes measures (PROMs) and satisfaction scores with a contemporary primary total knee arthroplasty (pTKA) cohort. METHODS: We retrospectively evaluated 25 consecutive cTKA patients (26 procedures) to define the utilized surgical techniques, radiographic disease severity, preoperative and postoperative PROMs (visual analog scale [VAS] pain, knee injury and osteoarthritis outcome score for joint replacement [KOOS-JR], University of California Los Angeles Activity), expected improvement and postoperative satisfaction (5-point Likert), and reoperations in comparison with an age and body mass index propensity matched cohort of 50 pTKA performed for osteoarthritis (52 procedures). RESULTS: Revision components were used in 12 cTKA cases (46.1%), with 4 cases requiring augmentation (15.4%), and 3 cases utilizing varus-valgus constraint (11.5%). While no significant differences were noted in expectation level or in other PROMs, mean patient reported satisfaction was lower in the conversion group (4.4 ± 1.1 versus 4.8 ± 0.5 points, P = .02). High cTKA satisfaction was associated with a higher postoperative KOOS-JR (84.4 versus 64.2 points, P = .01) and a trend towards higher University of California Los Angeles activity (6.9 versus 5.7 points, P = .08). Four patients in each group underwent manipulation (15.3 versus 7.6%, P = .42), and 1 pTKA patient was treated for early postoperative infection (0 versus 1.9%, P = 1.0). CONCLUSION: cTKA following failed biological replacement was associated with similar postoperative improvement as in pTKA. Lower patient-reported cTKA satisfaction was associated with lower postoperative KOOS-JR scores.
引用
- Oladeji LO, Albracht BG, Keeney JA, et al. Conversion Total Knee Arthroplasty After Failed Osteochondral Allograft Reconstruction: Similar Functional Performance With Lower Patient Satisfaction. J Arthroplasty. 2023. PMID: 36889527. doi:10.1016/j.arth.2023.02.084