文献速递关节外科

全膝关节置换术后麻醉下手法松解时关节内注射皮质类固醇的急性感染风险

The Risk of Acute Infection Following Intra-Articular Corticosteroid Injection During Total Knee Manipulation Under Anesthesia.
PubMed 文献 · J Arthroplasty · 2023-02-28

这项回顾性研究纳入209例患者(230膝),评估全膝关节置换术后麻醉下手法松解时关节内注射皮质类固醇后3个月内假体关节感染发生率。结果显示230膝中0例感染,且注射与术后6周活动度显著增加相关,该活动度在12个月随访期内得以维持。

要点

  • 230膝在手法松解时接受关节内皮质类固醇注射,90天内未发现假体关节感染(0/230)。
  • 手法松解后6周,总弧度和屈曲度分别平均增加25°和24°,并在12个月随访期内维持。
  • 最终随访时平均总弧度110°、屈曲111°,与术前(111°和113°)接近。

核心结论

  • 在全膝关节置换术后麻醉下手法松解时给予关节内皮质类固醇注射不增加急性假体关节感染风险。
  • 该操作与手法松解后6周短期活动度大幅增加相关,且此活动度在长期随访中得以维持。

研究设计与样本

  • 回顾性、IV级研究,共纳入209例患者(230膝),评估麻醉下手法松解时关节内皮质类固醇注射后3个月内假体关节感染发生率。
  • 约4.9%的初始患者随访不足,无法确定是否存在感染。
  • 对随访满1年及以上的患者(n=158)进行活动度评估,并在多个时间点记录。

主要发现

  • 在接受关节内皮质类固醇注射的230膝中,90天内未发现感染(0/230)。
  • 术前(preindex)患者平均总活动弧度111°、屈曲113°;手法松解前(pre-MUA)平均总弧度83°、屈曲86°。
  • 最终随访时平均总弧度110°、屈曲111°。
  • 手法松解后6周,总弧度和屈曲度分别平均增加25°和24°,达到1年时的活动度水平,并在12个月随访期内维持。

局限性

  • 本研究为回顾性、IV级研究。
  • 约4.9%的初始患者随访不足,无法确定感染是否存在。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Manipulation under anesthesia (MUA) is an established option for improving motion in patients presenting with early stiffness following total knee arthroplasty (TKA). Intra-articular corticosteroid injections (IACI) are sometimes administered adjunctively, yet literature examining their efficacy and safety remains limited. STUDY DESIGN: Retrospective, Level IV. METHODS: A total of 209 patients (TKA = 230) were retrospectively examined to determine the incidence of prosthetic joint infections within 3 months following manipulation with IACI. Approximately 4.9% of initial patients had inadequate follow-up where the presence of infection could not be determined. Range of motion was assessed in patients who had follow-up at or beyond one year (n = 158) and was recorded over multiple time points. RESULTS: No infections (0 of 230) were identified within 90 days of receiving IACI during TKA MUA. Before receiving TKA (preindex), patients averaged 111° of total arc of motion and 113° of flexion. Following index procedures, just prior to manipulation (pre-MUA), patients averaged 83° and 86° of total arc and flexion motion, respectively. At final follow-up, patients averaged 110° of total arc of motion and 111° of flexion. At six weeks following manipulation, patients had gained a mean of 25° and 24° of their total arc and flexion motion found at 1 year. This motion was preserved through a 12-month follow-up period. CONCLUSION: Administering IACI during TKA MUA does not harbor an elevated risk for acute prosthetic joint infections. Additionally, its use is associated with substantial increases in short-term range of motion at six weeks following manipulation, which remain preserved through long-term follow-up.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Bartlett LE, Henry JP, Lygrisse KA, et al. The Risk of Acute Infection Following Intra-Articular Corticosteroid Injection During Total Knee Manipulation Under Anesthesia. J Arthroplasty. 2023. PMID: 36863573. doi:10.1016/j.arth.2023.02.064

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。