文献速递关节外科

踝关节置换术能维持多久?

How long do ankle arthroplasties last?
PubMed 文献 · Bone Joint J · 2023-03-01

该数据链接研究结合英国国家关节登记处(NJR)与NHS Digital数据,分析2010年4月1日至2018年12月31日期间5562例初次踝关节置换术的生存率。总体五年生存率为90.2%,十年生存率为86.2%;固定轴承假体五年生存率94.3%高于活动轴承假体的89.4%。约三分之一的踝关节置换失败未上报至NJR,不同假体间生存率存在统计学显著差异。

要点

  • 英国初次踝关节置换术五年生存率为90.2%(95%CI 89.2%至91.1%),十年生存率为86.2%(95%CI 84.6%至87.6%)。
  • 固定轴承假体五年生存率94.3%(95%CI 91.3%至96.3%),高于活动轴承假体的89.4%(95%CI 88.3%至90.4%)。
  • 以生存率最佳的Infinity假体为参照,仅STAR(HR 1.60,95%CI 0.87至2.96)和INBONE(HR 0.38,95%CI 0.05至2.84)在三年和五年时未显示更差生存。

核心结论

  • 英国踝关节置换术五年生存率为90.2%,低于NJR记录,因为约三分之一的踝关节置换失败未上报至NJR。
  • 不同假体间生存率存在统计学显著差异,固定轴承假体似乎表现出比活动轴承假体更高的生存率。

研究设计与样本

  • 数据链接研究,结合国家关节登记处(NJR)数据与NHS Digital数据。
  • 共纳入5562例初次踝关节置换术,失败定义为植入装置任何组件的取出或更换。
  • 采用寿命表与Kaplan-Meier生存曲线展示生存率,拟合Cox比例风险回归模型比较2010年4月1日至2018年12月31日间的失败率。

主要发现

  • 一年生存率为98.8%(95%CI 98.4%至99.0%),2725例患者的五年生存率为90.2%(95%CI 89.2%至91.1%),199例患者的十年生存率为86.2%(95%CI 84.6%至87.6%)。
  • 固定轴承假体五年生存率为94.3%(95%CI 91.3%至96.3%),活动轴承假体为89.4%(95%CI 88.3%至90.4%)。
  • 以Infinity假体为参照,STAR的HR为1.60(95%CI 0.87至2.96),INBONE的HR为0.38(95%CI 0.05至2.84),两者在三年和五年时未显示更差生存。

关键数值与推荐

  • 失败定义为植入装置任何组件的取出或更换。
  • Cox回归模型仅纳入植入超过100例的假体,以生存率最佳的Infinity假体为参照。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 约三分之一的踝关节置换失败未上报至NJR,导致NJR记录的生存率高于链接数据所得。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Despite the increasing numbers of ankle arthroplasties, there are limited studies on their survival and comparisons between different implants. The primary aim of this study was to determine the failure rates of primary ankle arthroplasties commonly used in the UK. A data linkage study combined National Joint Registry (NJR) data and NHS Digital data. The primary outcome of failure was defined as the removal or exchange of any components of the implanted device. Life tables and Kaplan-Meier survival charts were used to illustrate survivorship. Cox proportional hazards regression models were fitted to compare failure rates between 1 April 2010 and 31 December 2018. Overall, 5,562 primary ankle arthroplasties were recorded in the NJR. Linked data show a one-year survivorship of 98.8% (95% confidence interval (CI) 98.4% to 99.0%), five-year survival in 2,725 patients of 90.2% (95% CI 89.2% to 91.1%), and ten-year survival in 199 patients of 86.2% (95% CI 84.6% to 87.6%). The five-year survival for fixed-bearing implants was 94.3% (95% CI 91.3% to 96.3%) compared to 89.4% (95% CI 88.3% to 90.4%) for mobile-bearing implants. A Cox regression model for all implants with over 100 implantations using the implant with the best survivorship (Infinity) as the reference, only the STAR (hazard ratio (HR) 1.60 (95% CI 0.87 to 2.96)) and INBONE (HR 0.38 (95% CI 0.05 to 2.84)) did not demonstrate worse survival at three and five years. Ankle arthroplasties in the UK have a five-year survival rate of 90.2%, which is lower than recorded on the NJR, because we have shown that approximately one-third of ankle arthroplasty failures are not reported to the NJR. There are statistically significant differences in survival between different implants. Fixed-bearing implants appear to demonstrate higher survivorship than mobile-bearing implants.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Jennison T, Ukoumunne O, Lamb S, et al. How long do ankle arthroplasties last? Bone Joint J. 2023. PMID: 36854343. doi:10.1302/0301-620X.105B3.BJJ-2022-0806.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。