文献速递关节外科

关节滑液中性粒细胞绝对计数作为假体周围关节感染生物标志物的研究

Absolute synovial polymorphonuclear neutrophil cell count as a biomarker of periprosthetic joint infection.
PubMed 文献 · Bone Joint J · 2023-03-15

这项回顾性队列研究纳入147例全髋或全膝关节置换术后出现急性或慢性症状并接受翻修手术的患者,评估滑液中性粒细胞绝对计数诊断假体周围关节感染的准确性。以2018年国际共识会议标准确诊,最佳截断值为2000个/微升(AUC 0.978),敏感度97.4%、特异度93.5%;全髋与全膝关节截断值不同,且该计数与滑液α-防御素强相关。

要点

  • 滑液中性粒细胞绝对计数截断值2000个/微升诊断假体周围关节感染的AUC为0.978,敏感度97.4%、特异度93.5%。
  • 全髋关节置换术截断值小于3600个/微升、全膝关节置换术截断值小于2000个/微升。
  • 滑液中性粒细胞绝对计数与滑液α-防御素强相关(r=0.759;p<0.001),α-防御素阳性时未额外发现感染病例。

核心结论

  • 滑液中性粒细胞绝对计数是假体周围关节感染诊断中广泛可用、快速、经济且准确的标志物,滑液α-防御素似乎是其替代指标。
  • 尽管在术后早期、磨损及风湿性疾病中确认感染存在局限,滑液中性粒细胞绝对计数低于2000个/微升高度适合排除假体周围关节感染,且全髋与全膝关节有特定截断值。

研究设计与样本

  • 回顾性队列研究,纳入147例全髋或全膝关节置换术后出现急性或慢性症状并接受翻修手术的连续患者。
  • 假体周围关节感染诊断依据2018年国际共识会议标准,其中39例诊断为感染(32例慢性、7例急性),108例为无菌性并发症。

主要发现

  • 受试者工作特征曲线确定滑液中性粒细胞绝对计数最佳截断值为2000个/微升,曲线下面积0.978(95%CI 0.946至1)。
  • 该截断值诊断假体周围关节感染的敏感度为97.4%(95%CI 91.2至100),特异度为93.5%(95%CI 88.9至98.1)。
  • 阳性预测值为84.4%(95%CI 72.7至93.9),阴性预测值为99.0%(95%CI 96.7至100)。
  • 排除20例急性并发症患者后,特异度提高至97.9%(95%CI 94.6至100)。
  • 全髋关节置换术截断值小于3600个/微升,全膝关节置换术截断值小于2000个/微升。

关键数值与推荐

  • 滑液中性粒细胞绝对计数截断值2000个/微升诊断假体周围关节感染的AUC为0.978(95%CI 0.946至1)。
  • 截断值2000个/微升的敏感度97.4%(95%CI 91.2至100)、特异度93.5%(95%CI 88.9至98.1)、阳性预测值84.4%(95%CI 72.7至93.9)、阴性预测值99.0%(95%CI 96.7至100)。
  • 排除20例急性并发症患者后特异度为97.9%(95%CI 94.6至100)。
  • 全髋关节置换术截断值小于3600个/微升,全膝关节置换术截断值小于2000个/微升。
  • 滑液中性粒细胞绝对计数与滑液α-防御素相关系数r=0.759(p<0.001)。

临床怎么用

  • 作者认为滑液中性粒细胞绝对计数是假体周围关节感染诊断中广泛可用、快速、经济且准确的标志物。
  • 作者认为滑液中性粒细胞绝对计数低于2000个/微升高度适合排除假体周围关节感染,全髋与全膝关节应采用各自的特定截断值。
  • 作者指出在术后早期、磨损及风湿性疾病中确认假体周围关节感染存在局限。

局限性

  • 原文指出在术后早期、磨损及风湿性疾病中确认假体周围关节感染存在局限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The aim of this study was to evaluate the diagnostic accuracy of the absolute synovial polymorphonuclear neutrophil cell (PMN) count for the diagnosis or exclusion of periprosthetic joint infection (PJI) after total hip (THA) or knee arthroplasty (TKA). In this retrospective cohort study, 147 consecutive patients with acute or chronic complaints following THA and TKA were included. Diagnosis of PJI was established based on the 2018 International Consensus Meeting criteria. A total of 39 patients diagnosed with PJI (32 chronic and seven acute) and 108 patients with aseptic complications were surgically revised. Using receiver operating characteristic curves and calculating the area under the curve (AUC), an optimal synovial cut-off value of 2,000 PMN/µl was determined (AUC 0.978 (95% confidence interval (CI) 0.946 to 1)). Using this cut-off, sensitivity and specificity of absolute synovial PMN count for PJI were 97.4% (95% CI 91.2 to 100) and 93.5% (95% CI 88.9 to 98.1), respectively. Positive and negative predictive value were 84.4% (95% CI 72.7 to 93.9) and 99.0% (95% CI 96.7 to 100), respectively. Exclusion of 20 patients with acute complications improved specificity to 97.9% (95% CI 94.6 to 100). Different cut-off values for THA (< 3,600 PMN/µl) and TKA (< 2,000 PMN/µl) were identified. Absolute synovial PMN count correlated strongly with synovial alpha-defensin (AD) (r = 0.759; p < 0.001). With a positive AD result, no additional PJI could be identified in any case. Absolute synovial PMN count is a widely available, rapid, cost-effective, and accurate marker in PJI diagnostics, whereas synovial AD appears to be a surrogate parameter of absolute synovial PMN count. Despite limitations in the early postoperative phase, wear, and rheumatic diseases in confirming PJI, an absolute synovial PMN count below 2,000/µl is highly suitable for ruling out PJI, with specific cut-off values for THA and TKA.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Jandl NM, Kleiss S, Mussawy H, et al. Absolute synovial polymorphonuclear neutrophil cell count as a biomarker of periprosthetic joint infection. Bone Joint J. 2023. PMID: 36924172. doi:10.1302/0301-620X.105B4.BJJ-2022-0628.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。