定制三翼髋臼植入物:平均10年随访
本研究报道了42例(41名患者)因Paprosky 3A或3B髋臼骨缺损行翻修全髋关节置换术并采用定制三翼髋臼假体的6至13年临床结果,平均随访10年时平均Harris评分为74分,38个(95%)假体影像学稳定,但脱位和感染仍是主要失败原因。
要点
- 在平均10年随访时,95%(38/40)的定制三翼髋臼假体影像学稳定。
- 深部感染发生2例(5%),其中1例(2.5%)因深部感染取出假体。
- 3髋(7.5%)共发生4次脱位,仅1髋因脱位翻修(仅更换股骨组件)。
核心结论
- 在不稳定和感染仍是复杂重建失败主要原因的情况下,平均随访10年时定制三翼髋臼植入物在髋臼骨广泛侵蚀背景下似乎至少与巨杯和杯笼结构效果相当。
研究设计与样本
- 2008年至2015年3月期间,在本机构对41名患者(42例翻修全髋关节置换术)使用定制三翼髋臼组件,所有翻修均涉及Paprosky 3A或3B髋臼缺损。
- 2名患者在五年随访前死亡,其余40例翻修全髋关节置换术的平均随访时间为10年(范围6至13年)。
- Harris髋关节评分在6个月、1年及此后每2至3年获取。
主要发现
- 末次随访时平均Harris评分为74分。
- 深部感染2例(5%),其中1例定制植入物因深部感染取出(2.5%)。
- 3髋(7.5%)共发生4次脱位,其中1髋因脱位翻修(仅更换股骨组件)。
- 1例定制植入物被判为松动。
- 末次随访时38例(95%)定制髋臼植入物被认为影像学稳定。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Acetabular reconstruction options in the setting of substantial bone deficiency (Paprosky 3A and 3B) remain limited. Custom triflange acetabular implants are one choice for this challenging problem. However, few studies have reported on survivorship beyond 3 to 5 years. The purpose of this study was to report our 6 to 13-year clinical results using these custom-made acetabular components. METHODS: Between 2008 and March 2015, 42 revision total hip arthroplasties (41 patients) were performed at our institution with a custom triflange acetabular component. All revisions involved either Paprosky 3A or 3B acetabular defects. Two patients died before the five-year follow-up. Harris Hip Scores were obtained at 6 months, 1 year, and every 2 to 3 years thereafter. The average follow-up in the remaining 40 revision total hip arthroplasties was 10 years (range, 6 to 13 years). RESULTS: At the final follow-up, the mean Harris score was 74 points. There were two deep infections (5%). One custom implant was removed for deep infection (2.5%). Three hips (7.5%) experienced a total of four dislocations necessitating revision in one hip (femoral component only). One custom implant was judged to be loose. There were no cases of femoral nerve palsy. At final follow-up, 38 (95%) of the custom acetabular implants were considered radiographically stable. CONCLUSION: Instability and infection remain a major concern and cause of failure in these complex reconstructions. At an average follow-up of 10 years, however, custom triflange acetabular implants appear to work at least as well as jumbo cups and cup/cage constructs in the setting of extensive erosion of acetabular bone.
引用
- Meding JB, Meding LK. Custom Triflange Acetabular Implants: Average 10-Year Follow-Up. J Arthroplasty. 2023. PMID: 36958713. doi:10.1016/j.arth.2023.03.035
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。