文献速递小儿骨科脊柱外科

磁控生长棒延长中棒长度增加与矢状面序列改变的预测因素

Predictors of Rod Length Gain and Sagittal Alignment Change After Magnetically Controlled Growing Rod Lengthening.
PubMed 文献 · Spine (Phila Pa 1976) · 2023-02-27

这项回顾性队列研究纳入56例早发性脊柱侧凸患者,分析磁控生长棒延长过程中棒长度增加的预测因素及矢状面改变。结果显示术前T1-T12高度较短和植入后初始矫形率较高是棒长度增加的显著预测因素,胸椎后凸在延长阶段未恶化。

要点

  • 术前T1-T12高度较短和植入后初始矫形率较高是磁控生长棒长度增加的显著预测因素。
  • 诊断类型、术前主弯大小和胸椎后凸与棒长度增加无关。
  • 胸椎后凸在延长阶段未恶化,腰椎前凸在延长期间增加。

核心结论

  • 磁控生长棒长度增加最多的患者是术前T1-T12高度较短且植入时初始矫形较好的患者,可能代表植入物在体型小、柔韧性好的患者中效果最佳。
  • 诊断、术前弯度大小和胸椎后凸与棒长度增加无关。
  • 胸椎后凸在延长阶段未恶化。

研究设计与样本

  • 回顾性队列研究,纳入56例接受磁控生长棒治疗且随访至少2年的早发性脊柱侧凸患者,排除既往脊柱手术者。
  • 患者包括9例特发性、5例先天性、14例神经肌肉型、20例综合征型和8例骨骼发育不良。
  • 检查植入前、植入后和末次随访延长后的X线片,采用多元线性回归分析棒长度增加的预测因素。

主要发现

  • 早发性脊柱侧凸各亚型间棒长度增加无差异(P=0.62)。
  • 术前T1-T12高度较短和植入后矫形率较高是棒长度增加的显著预测因素(P<0.001)。
  • 术前主弯大小和后凸不是显著预测因素。
  • 植入后可见驱动器周围脊柱变平及T1-T5后凸代偿性增加。
  • 延长期间最大矢状面后凸、T1-T5后凸和T5-T12后凸无变化。

关键数值与推荐

  • 原文未报告。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

STUDY DESIGN: This was a retrospective cohort study. OBJECTIVE: There are preoperative characteristics that predict rod lengthening of magnetically controlled growing rods (MCGR). The lengthening of MCGR will lead to increased kyphosis. SUMMARY OF BACKGROUND DATA: The amount of length gained by MCGR is variable, and predictors are lacking. Similarly, sagittal plane changes over the MCGR lengthening period have not been investigated. MATERIALS AND METHODS: Patients with MCGR and a minimum 2-year follow-up were identified and those with previous spine surgery were excluded. Preimplantation, postimplantation, and last follow-up postlengthening radiographs were examined. Multiple linear regression analyses were used for rod length gain predictors. RESULTS: Fifty-six patients with early-onset scoliosis met inclusion criteria: nine idiopathic, five congenital, 14 neuromuscular, 20 syndromic, and eight skeletal dysplasia patients. No difference was seen between subtypes of early-onset scoliosis for rod length gain ( P =0.62). Shorter preoperative T1-T12 height and higher curve correction rate after implantation were significant predictors for rod length gain ( P <0.001). Preoperative major curve magnitude and kyphosis were not significant predictors. Flattening of the spine around the actuator and compensative increase in T1-T5 kyphosis were seen secondarily after MCGR implantation. Maximum sagittal kyphosis, T1-T5 kyphosis, and T5-T12 kyphosis did not change during lengthening. Lumbar lordosis significantly decreased postimplantation (first erect) but then increased during lengthening. Pelvic incidence and sacral slope both increased during lengthening, but this may be age related. CONCLUSION: Patients who gained the most rod length with MCGR were those with an initially shorter T1-T12 height and better initial curve correction at implantation, likely representing that implants work best in small patients with flexible curves. Diagnosis, preoperative curve magnitude, and thoracic kyphosis were not related to rod length gain. Thoracic kyphosis did not deteriorate over the lengthening phase. LEVEL OF EVIDENCE: Level III-retrospective cohort study.

来源:Spine (Phila Pa 1976),查看原文。版权归原作者所有。

引用

  1. Asma A, Fralinger D, da Silva LCA, et al. Predictors of Rod Length Gain and Sagittal Alignment Change After Magnetically Controlled Growing Rod Lengthening. Spine (Phila Pa 1976). 2023. PMID: 36856517. doi:10.1097/BRS.0000000000004616

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。