文献速递脊柱外科小儿骨科

脊柱立体栅格摄影对青少年特发性脊柱侧凸早期诊断的试验特征

Test characteristics of rasterstereography for the early diagnosis of adolescent idiopathic scoliosis.
PubMed 文献 · Bone Joint J · 2023-03-15

研究纳入212例疑似青少年特发性脊柱侧凸的青少年,评估脊柱立体栅格摄影的脊柱侧凸角(SA)、最大椎体表面旋转(ROT)及脊柱侧凸测量计的躯干旋转角(ATR)对Cobb角>10°的诊断价值。SA的AUC为0.74,ATR为0.82,ROT为0.65;ROT的AUC显著低于ATR和SA,ATR与SA的AUC无显著差异。

要点

  • SA诊断Cobb角>10°的AUC为0.74,阈值为12.5°时敏感度75%、特异度65%。
  • ATR诊断Cobb角>10°的AUC为0.82,阈值为5.5°时敏感度65%、特异度80%。
  • ROT的AUC为0.65,显著低于ATR和SA;ATR与SA的AUC无显著差异。

核心结论

  • 脊柱立体栅格摄影的脊柱侧凸角诊断特征优于脊柱侧凸测量计的躯干旋转角,两者AUC相似,但脊柱侧凸角敏感度更高。

研究设计与样本

  • 纳入疑似青少年特发性脊柱侧凸并计划行X线检查的青少年,评估脊柱立体栅格摄影的脊柱侧凸角、最大椎体表面旋转及脊柱侧凸测量计的躯干旋转角。
  • 采用受试者工作特征曲线下面积描述各指标对脊柱侧凸(定义为Cobb角>10°)的判别能力。
  • 采用约登法确定最佳阈值并报告敏感度和特异度,采用bootstrap检验比较两相关ROC曲线法比较各指标AUC。

主要发现

  • 212例患者中146例(69%)患有青少年特发性脊柱侧凸。
  • 脊柱侧凸角的AUC为0.74(阈值12.5°,敏感度75%,特异度65%)。
  • 最大椎体表面旋转的AUC为0.65(阈值7.5°,敏感度63%,特异度64%)。
  • 躯干旋转角的AUC为0.82(阈值5.5°,敏感度65%,特异度80%)。
  • 最大椎体表面旋转的AUC显著低于躯干旋转角(p < 0.001)和脊柱侧凸角(p < 0.001);躯干旋转角与脊柱侧凸角的AUC无显著差异(p = 0.115)。

关键数值与推荐

  • 脊柱侧凸角诊断Cobb角>10°的AUC为0.74,阈值为12.5°,敏感度75%,特异度65%。
  • 最大椎体表面旋转诊断Cobb角>10°的AUC为0.65,阈值为7.5°,敏感度63%,特异度64%。
  • 躯干旋转角诊断Cobb角>10°的AUC为0.82,阈值为5.5°,敏感度65%,特异度80%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

This study aimed to evaluate rasterstereography of the spine as a diagnostic test for adolescent idiopathic soliosis (AIS), and to compare its results with those obtained using a scoliometer. Adolescents suspected of AIS and scheduled for radiographs were included. Rasterstereographic scoliosis angle (SA), maximal vertebral surface rotation (ROT), and angle of trunk rotation (ATR) with a scoliometer were evaluated. The area under the curve (AUC) from receiver operating characteristic (ROC) plots were used to describe the discriminative ability of the SA, ROT, and ATR for scoliosis, defined as a Cobb angle > 10°. Test characteristics (sensitivity and specificity) were reported for the best threshold identified using the Youden method. AUC of SA, ATR, and ROT were compared using the bootstrap test for two correlated ROC curves method. Of 212 patients studied, 146 (69%) had an AIS. The AUC was 0.74 for scoliosis angle (threshold 12.5°, sensitivity 75%, specificity 65%), 0.65 for maximal vertebral surface rotation (threshold 7.5°, sensitivity 63%, specificity 64%), and 0.82 for angle of trunk rotation (threshold 5.5°, sensitivity 65%, specificity 80%). The AUC of ROT was significantly lower than that of ATR (p < 0.001) and SA (p < 0.001). The AUCs of ATR and SA were not significantly different (p = 0.115). The rasterstereographic scoliosis angle has better diagnostic characteristics than the angle of trunk rotation evaluated with a scoliometer, with similar AUCs and a higher sensitivity.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Vendeuvre T, Tabard-Fougère A, Armand S, et al. Test characteristics of rasterstereography for the early diagnosis of adolescent idiopathic scoliosis. Bone Joint J. 2023. PMID: 36924187. doi:10.1302/0301-620X.105B4.BJJ-2021-1440.R3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。