椎体骨质量评分预测退行性腰椎疾病术后椎弓根螺钉松动
本研究为回顾性研究,纳入156例接受腰椎椎弓根螺钉固定的退行性腰椎疾病患者,评估基于MRI的椎体骨质量(VBQ)评分对螺钉松动的预测价值,并与Hounsfield单位(HU)值比较。结果显示螺钉松动率为35%(55/156),松动组VBQ评分高于非松动组(3.28±0.58 vs 2.82±0.50,P<0.01),多因素分析中VBQ评分(OR 3.908,95%CI 1.624-9.405,P=0.002)与螺钉松动相关,VBQ评分预测松动的曲线下面积(AUC)为0.720,优于HU值的0.702。结论认为VBQ评分是与螺钉松动相关的影响因素,且预测价值优于HU值。
要点
- 156例退行性腰椎疾病患者术后螺钉松动率为35%(55/156)。
- 松动组VBQ评分高于非松动组(3.28±0.58 vs 2.82±0.50,P<0.01)。
- VBQ评分预测螺钉松动的AUC为0.720,优于HU值的0.702。
核心结论
- VBQ评分是与腰椎椎弓根螺钉松动相关的影响因素,较高的VBQ评分与较高的螺钉松动风险显著相关。
- 在因退行性腰椎疾病接受椎弓根螺钉固定的患者中,VBQ评分对螺钉松动的预测价值优于HU值。
研究设计与样本
- 回顾性研究,纳入接受腰椎椎弓根螺钉固定的患者,最终分析156例。
- VBQ评分通过磁共振成像(MRI)扫描测量,L1至L4腰椎骨密度HU值通过计算机断层扫描(CT)测量。
- 采用逻辑回归分析识别与椎弓根螺钉松动相关的因素,采用受试者工作特征(ROC)曲线分析评估VBQ评分的预测价值。
主要发现
- 椎弓根螺钉松动率为35%(55/156例)。
- 松动组术后腰痛视觉模拟量表(VAS)评分高于非松动组(3.0±2.0 vs 2.4±1.8,P<0.05)。
- 松动组VBQ评分高于非松动组(3.28±0.58 vs 2.82±0.50,P<0.01)。
- 多因素分析中,非单节段固定(OR 3.992,95%CI 1.643-9.701,P=0.002)、最低固定椎位于S1(OR 3.378,95%CI 1.387-8.226,P=0.007)、HU值(OR 0.988,95%CI 0.976-1.000,P=0.047)和VBQ评分(OR 3.908,95%CI 1.624-9.405,P=0.002)是与螺钉松动相关的因素。
- VBQ评分和HU值预测椎弓根螺钉松动的曲线下面积分别为0.720和0.702;VBQ评分预测螺钉松动的最佳阈值为3.05(灵敏度0.655,特异度0.713)。
关键数值与推荐
- VBQ评分预测椎弓根螺钉松动的最佳阈值为3.05,灵敏度0.655,特异度0.713。
- VBQ评分预测螺钉松动的AUC为0.720,HU值为0.702。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
STUDY DESIGN: Retrospective study. OBJECTIVE: To investigate whether magnetic resonance imaging-based vertebral bone quality (VBQ) score can predict pedicle screw loosening in patients who underwent pedicle screw fixation, and to compare, which measurement, the VBQ score or the Hounsfield unit (HU) value, is more predictive of pedicle screw loosening. SUMMARY OF BACKGROUND DATA: In clinical work, we found that patients with screw loosening had higher VBQ scores. In addition, some studies have found a correlation between VBQ scores and osteoporosis. PATIENTS AND METHODS: Patients who were treated with lumbar pedicle screw fixation were reviewed. The VBQ score was measured using magnetic resonance imaging scans. The HU value for L1 to L4 lumbar bone mineral density was measured with computed tomography scans. Logistic regression analysis was used to identify factors associated with pedicle screw loosening. Receiver-operating characteristic curve analysis was used to evaluate the value of VBQ scores in predicting pedicle screw loosening. RESULTS: A total of 156 patients were included in the final analysis. The pedicle screw loosening rate was 35% (55 of 156 patients). The postoperative low-back pain visual analog scale score was higher in the loosening group (3.0 ± 2.0 vs . 2.4 ± 1.8; P < 0.05). The VBQ score was higher in the loosening group than in the nonloosening group (3.28 ± 0.58 vs . 2.82 ± 0.50; P < 0.01). In multivariable analysis, nonsingle segment fixation [odds ratio (OR): 3.992; 95% CI: 1.643-9.701; P = 0.002], lowest instrumented vertebrae at S1 (OR: 3.378; 95% CI: 1.387-8.226; P = 0.007), HU value (OR: 0.988; 95% CI: 0.976-1.000; P = 0.047), and VBQ score (OR: 3.908; 95% CI: 1.624-9.405; P = 0.002) were factors associated with screw loosening. The areas under the curve for using the VBQ score and HU value to predict pedicle screw loosening were 0.720 and 0.702, respectively. The optimal VBQ score threshold was 3.05 for predicting pedicle screw loosening (sensitivity: 0.655; specificity: 0.713). CONCLUSIONS: The VBQ score was an influential factor associated with lumbar pedicle screw loosening, and a higher VBQ score was significantly correlated with a higher risk of screw loosening. The VBQ score was a better predictor of pedicle screw loosening than the HU value in patients who underwent pedicle screw fixation for degenerative lumbar disease.
引用
- Li W, Zhu H, Hua Z, et al. Vertebral Bone Quality Score as a Predictor of Pedicle Screw Loosening Following Surgery for Degenerative Lumbar Disease. Spine (Phila Pa 1976). 2023. PMID: 36728017. doi:10.1097/BRS.0000000000004577
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。