文献速递运动医学创伤骨科

外旋背屈位常规踝关节CT对急性孤立性下胫腓联合不稳的诊断准确性

Diagnostic Accuracy of Conventional Ankle CT Scan With External Rotation and Dorsiflexion in Patients With Acute Isolated Syndesmotic Instability.
PubMed 文献 · Am J Sports Med · 2023-02-15

前瞻性队列研究纳入68例急性下胫腓联合损伤疑似患者,比较中立位、外旋背屈伸膝位和外旋背屈屈膝位三种CT扫描对下胫腓联合不稳的诊断准确性,以MRI为参考标准。旋转测量在外旋背屈位扫描的AUC(0.97和0.99)高于中立位(0.62),最佳截断值1.0 mm时敏感度和特异度分别为83%/97%和86%/100%。

要点

  • 外旋背屈位踝关节CT诊断下胫腓联合旋转不稳的AUC达0.97和0.99,优于中立位的0.62。
  • 旋转测量最佳截断值1.0 mm时,伸膝位扫描敏感度83%、特异度97%,屈膝位扫描敏感度86%、特异度100%。
  • 中立位CT旋转测量最佳截断值0.7 mm时敏感度仅25%、特异度97%。

核心结论

  • 常规踝关节CT施加应力动作对诊断轻微下胫腓联合旋转不稳表现优异,与中立位踝关节CT相比,在最佳截断点处显示出更高的AUC和更强的敏感度。

研究设计与样本

  • 前瞻性队列研究(诊断性),证据等级2级;2018年9月至2021年4月连续纳入因急性下胫腓联合损伤骨科查体阳性就诊于足踝门诊的成人,共分析68例参与者(平均年龄36.5岁,范围18-69岁)的影像,其中下胫腓联合损伤36例、外侧副韧带损伤32例;以MRI为参考标准。

主要发现

  • 旋转测量a在第二次(外旋背屈伸膝位)和第三次(外旋背屈屈膝位)应力CT扫描的AUC分别为0.97和0.99,高于第一次中立位CT扫描的0.62。
  • 应力动作扫描旋转测量a的最佳截断值为1.0 mm,第二次伸膝位扫描敏感度83%、特异度97%,第三次屈膝位扫描敏感度86%、特异度100%。
  • 中立位第一次CT扫描旋转测量a的最佳截断值为0.7 mm,敏感度25%、特异度97%。

关键数值与推荐

  • 诊断准确性比较采用曲线下面积(AUC),理想截断点通过约登J指数计算确定。
  • 旋转测量a在外旋背屈伸膝位扫描AUC为0.97,外旋背屈屈膝位扫描AUC为0.99,中立位扫描AUC为0.62。
  • 旋转测量a应力动作扫描最佳截断值1.0 mm:伸膝位扫描敏感度83%、特异度97%;屈膝位扫描敏感度86%、特异度100%。
  • 旋转测量a中立位扫描最佳截断值0.7 mm:敏感度25%、特异度97%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Syndesmotic injury in an athletic population is associated with a prolonged ankle disability after an ankle sprain and often requires a longer recovery than a lateral collateral ligament injury. Although several imaging tests are available, diagnosing syndesmotic instability remains challenging. PURPOSE: To determine the diagnostic accuracy of conventional ankle computed tomography (CT) scans with the joint in external rotation and dorsiflexion and compare it with that of conventional ankle CT scans in a neutral position. STUDY DESIGN: Cohort study (Diagnosis); Level of evidence, 2. METHODS: Between September 2018 and April 2021, this prospective study consecutively included adults visiting the foot and ankle outpatient clinic with a positive orthopaedic examination for acute syndesmotic injury. Participants underwent 3 CT scan tests. First, ankles were scanned in a neutral position. Second, ankles were scanned with 45° of external rotation, dorsiflexion, and extended knees. Third, ankles were scanned with 45° of external rotation, dorsiflexion, and flexed knees. Three measurements, comprising rotation (measurement a), lateral translation (measurement c), and anteroposterior translation (measurement f) of the fibula concerning the tibia, were used to diagnose syndesmotic instability in the 3 CT scans. Magnetic resonance imaging was used as a reference standard. The area under the curve (AUC) was used to compare the diagnostic accuracy, and Youden's J index was calculated to determine the ideal cutoff point. RESULTS: Images obtained in 68 participants (mean age, 36.5 years; range, 18-69 years) were analyzed, comprising 36 syndesmotic injuries and 32 lateral collateral ligament injuries. The best diagnostic accuracy occurred with the rotational measurement a, in which the second and third CT scans with stress maneuvers presented greater AUCs (0.97 and 0.99) than did the first CT scan in a neutral position (0.62). The ideal cutoff point for the stress maneuvers was 1.0 mm in the rotational measurement a and reached a sensitivity and specificity of 83% and 97% for the second CT scan with extended knees and 86% and 100% for the third CT scan with flexed knees, respectively. The ideal cutoff point for the first CT scan with a neutral position was 0.7 mm in the rotational measurement a, with a sensitivity of 25% and specificity of 97%. CONCLUSION: Conventional ankle CT with stress maneuvers has excellent performance for diagnosing subtle syndesmotic rotational instability, as it shows a greater AUC and enhanced sensitivity at the ideal cutoff point compared with ankle CT in the neutral position.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Rodrigues JC, do Amaral E Castro A, Rosemberg LA, et al. Diagnostic Accuracy of Conventional Ankle CT Scan With External Rotation and Dorsiflexion in Patients With Acute Isolated Syndesmotic Instability. Am J Sports Med. 2023. PMID: 36790178. doi:10.1177/03635465231153144

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。