文献速递运动医学关节外科

阔筋膜自体移植联合与不联合聚丙烯补片增强上关节囊重建术后早期MRI评估

Early Postoperative MRI Evaluation of a Fascia Lata Autograft With and Without Polypropylene Mesh Augmentation After Superior Capsular Reconstruction.
PubMed 文献 · Am J Sports Med · 2023-02-14

该回顾性队列研究纳入78例上关节囊重建术后3个月移植物完整的患者,比较阔筋膜自体移植联合聚丙烯补片增强组(54例)与单纯阔筋膜自体移植组(24例)的MRI信号噪声商(SNQ)。联合补片组平均SNQ为18.367,低于单纯移植组的30.603(P < .001),肱骨侧和中间实质部位也显著更低,但关节盂侧无显著差异。作者认为补片的使用可能增强阔筋膜自体移植的愈合与重塑。

要点

  • 联合补片组平均SNQ为18.367,低于单纯移植组的30.603(P < .001)。
  • 肱骨侧SNQ联合补片组15.512 vs 单纯移植组37.863(P < .001),中间实质部位16.878 vs 29.168(P = .003)。
  • 关节盂侧SNQ两组无显著差异(20.354 vs 25.346,P = .057)。

核心结论

  • 术后3个月随访时,阔筋膜自体移植联合聚丙烯补片增强组的MRI信号强度低于单纯阔筋膜自体移植组。
  • 使用补片时,阔筋膜自体移植的愈合与重塑可能得到增强。

研究设计与样本

  • 研究类型为队列研究,证据等级为3级。
  • 回顾性分析2013年3月至2021年8月期间接受上关节囊重建术的患者资料。
  • 共纳入78例移植物完整的患者,其中单纯阔筋膜自体移植组24例,联合聚丙烯补片增强组54例。
  • 术后3个月进行随访MRI,通过分析肱骨侧、中间实质部位和关节盂侧的信号噪声商(SNQ)评估移植物重塑。

主要发现

  • 平均SNQ在单纯阔筋膜自体移植组为30.603(范围11.790-72.710),在联合补片组为18.367(范围4.464-69.500),P < .001。
  • 肱骨侧SNQ在单纯移植组为37.863(范围5.092-81.187),在联合补片组为15.512(范围1.814-80.869),P < .001。
  • 中间实质部位SNQ在单纯移植组为29.168(范围6.103-73.900),在联合补片组为16.878(范围2.454-92.416),P = .003。
  • 关节盂侧SNQ在单纯移植组为25.346(范围7.565-86.353),在联合补片组为20.354(范围3.732-88.468),P = .057,两组间无显著差异。

关键数值与推荐

  • 理论上,较低的SNQ比值表示移植物具有更高的强度和更好的愈合。
  • 术后3个月随访MRI显示,联合补片组平均SNQ为18.367,低于单纯移植组的30.603(P < .001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Recently, a polypropylene mesh has been introduced and reported to improve clinical outcomes after superior capsular reconstruction (SCR) using a fascia lata autograft (FLA). However, mesh-related events such as a foreign body response may trigger inflammation, which might affect graft healing and remodeling. PURPOSE/HYPOTHESIS: The aim was to investigate whether the healing and remodeling of an FLA were affected by the use of a mesh by comparing the signal intensity of an FLA-alone group vs an FLA + Mesh group on postoperative magnetic resonance imaging (MRI). The hypothesis was that the use of a mesh would decrease the MRI signal intensity of FLA during the early postoperative phase. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: Patients who had undergone SCR using an FLA with or without a mesh between March 2013 and August 2021 were retrospectively analyzed. Follow-up MRI was performed at 3 months. A total of 78 patients (24 in the FLA group and 54 in the FLA + Mesh group) with intact grafts were included. Graft remodeling was evaluated by analyzing the signal-to-noise quotient (SNQ) at the humeral, mid-substance, and glenoid sites. Theoretically, lower SNQ ratios indicate higher strength and better healing of the graft. RESULTS: The mean SNQ was 30.603 (range, 11.790-72.710) in the FLA group and 18.367 (range, 4.464-69.500) in the FLA + Mesh group (P < .001). Furthermore, significant differences were found between the 2 groups at the humeral and mid-substance sites (37.863 [range, 5.092-81.187] vs 15.512 [range, 1.814-80.869], P < .001; and 29.168 [range, 6.103-73.900] vs 16.878 [range, 2.454-92.416], P = .003; respectively). However, there was no difference between the 2 groups at the glenoid site (25.346 [range, 7.565-86.353] vs 20.354 [range, 3.732-88.468], P = .057). CONCLUSION: At the 3-month follow-up, the FLA + Mesh group showed a lower MRI signal intensity than the FLA group. The healing and remodeling of an FLA may be enhanced when a mesh is used.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Ben H, Kholinne E, Zeng CH, et al. Early Postoperative MRI Evaluation of a Fascia Lata Autograft With and Without Polypropylene Mesh Augmentation After Superior Capsular Reconstruction. Am J Sports Med. 2023. PMID: 36786289. doi:10.1177/03635465231151927

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。