文献速递运动医学关节外科

使用低成本动作捕捉系统评估落地垂直跳参数对非接触性前交叉韧带损伤的预后价值

Using an Affordable Motion Capture System to Evaluate the Prognostic Value of Drop Vertical Jump Parameters for Noncontact ACL Injury.
PubMed 文献 · Am J Sports Med · 2023-02-15

研究前瞻性招募102名大学校队运动员,用低成本动作捕捉系统(Kinect)记录落地垂直跳时膝关节角度,随访一个赛季发现5例非接触性前交叉韧带损伤。损伤者峰值冠状面外展角显著更大、峰值矢状面屈曲角显著更小(均P=.049),ROC曲线下面积分别为初始冠状角0.88、峰值冠状角0.92、峰值矢状屈曲角0.90。

要点

  • 落地垂直跳峰值冠状角增大与峰值矢状屈曲角减小与非接触性前交叉韧带损伤风险增加显著相关。
  • 初始冠状角、峰值冠状角、峰值矢状屈曲角的ROC曲线下面积分别为0.88、0.92、0.90。
  • 低成本动作捕捉系统有望成为大规模前交叉韧带损伤风险筛查的经济实用选择。

核心结论

  • 落地垂直跳中峰值冠状角增大和峰值矢状角减小与非接触性前交叉韧带损伤风险增加显著相关。
  • 基于ROC分析,初始冠状角具有良好的预后能力,而峰值冠状角和峰值矢状屈曲角具有极好的预后能力。
  • 低成本动作捕捉系统有望成为大规模前交叉韧带损伤风险筛查的经济实用选择。

研究设计与样本

  • 病例对照研究,证据等级3。
  • 从大学校队体育项目前瞻性招募102名参与者,其中101名运动员(99%)完成整个赛季的非接触性前交叉韧带损伤随访。
  • 每名运动员完成3次落地垂直跳,使用低成本动作捕捉系统(Kinect;Microsoft)记录数据,由软件识别膝关节初始冠状面、峰值冠状面和峰值矢状面角度。

主要发现

  • 101名运动员中5名发生非接触性前交叉韧带损伤。
  • 前交叉韧带损伤运动员的峰值冠状角显著更大、峰值矢状屈曲角显著更小(分别为P=.049、P=.049)。
  • ROC分析显示初始冠状角、峰值冠状角、峰值矢状屈曲角的曲线下面积分别为0.88、0.92、0.90。
  • 在本研究队列中,初始冠状角切点2.96°的敏感性为80%、特异性为72%,峰值冠状角切点6.16°的敏感性为80%、特异性为72%,峰值矢状屈曲角切点93.82°的敏感性为80%、特异性为74%。

关键数值与推荐

  • 初始冠状角切点2.96°:敏感性80%,特异性72%。
  • 峰值冠状角切点6.16°:敏感性80%,特异性72%。
  • 峰值矢状屈曲角切点93.82°:敏感性80%,特异性74%。
  • ROC曲线下面积:初始冠状角0.88,峰值冠状角0.92,峰值矢状屈曲角0.90。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Knee kinematic parameters during a drop vertical jump (DVJ) have been demonstrated to be associated with increased risk of noncontact anterior cruciate ligament (ACL) injury. However, standard motion analysis systems are not practical for routine screening. Affordable and practical motion sensor alternatives exist but require further validation in the context of ACL injury risk assessment. PURPOSE/HYPOTHESIS: To prospectively study DVJ parameters as predictors of noncontact ACL injury in collegiate athletes using an affordable motion capture system (Kinect; Microsoft). We hypothesized that athletes who sustained noncontact ACL injury would have larger initial and peak contact coronal abduction angles and smaller peak flexion angles at the knee during a DVJ. STUDY DESIGN: Case-control study; Level of evidence, 3. METHODS: 102 participants were prospectively recruited from a collegiate varsity sports program. A total of 101 of the 102 athletes (99%) were followed for an entire season for noncontact ACL injury. Each athlete performed 3 DVJs, and the data were recorded using the motion capture system. Initial coronal, peak coronal, and peak sagittal angles of the knee were identified by our software. RESULTS: Five of the 101 athletes sustained a noncontact ACL injury. Peak coronal angles were significantly greater and peak sagittal flexion angles were significantly smaller in ACL-injured athletes (P = .049, P = .049, respectively). Receiver operating characteristic (ROC) analysis demonstrated an area under the curve of 0.88, 0.92, and 0.90 for initial coronal, peak coronal, and peak sagittal angle, respectively. An initial coronal angle cutoff of 2.96° demonstrated 80% sensitivity and 72% specificity, a peak coronal angle cutoff of 6.16° demonstrated 80% sensitivity and 72% specificity, and a peak sagittal flexion cutoff of 93.82° demonstrated 80% sensitivity and 74% specificity on the study cohort. CONCLUSION: Increased peak coronal angle and decreased peak sagittal angle during a DVJ were significantly associated with increased risk for noncontact ACL injury. Based on ROC analysis, initial coronal angle showed good prognostic ability, whereas peak coronal angle and peak sagittal flexion provided excellent prognostic ability. Affordable motion capture systems show promise as cost-effective and practical options for large-scale ACL injury risk screening.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Corban J, Karatzas N, Zhao KY, et al. Using an Affordable Motion Capture System to Evaluate the Prognostic Value of Drop Vertical Jump Parameters for Noncontact ACL Injury. Am J Sports Med. 2023. PMID: 36790216. doi:10.1177/03635465231151686

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。