股四头肌腱移植物厚度与等速肌力表现的相关性
该队列研究纳入2021年6月至11月接受前交叉韧带重建(ACLR)的26例患者,比较全厚股四头肌腱(FT-Q)与部分厚股四头肌腱(PT-Q)移植术后超过1年的等速膝关节伸展表现。FT-Q组术侧峰值扭矩、平均功率和总做功均显著低于非术侧,而PT-Q组术侧与非术侧无显著差异。
要点
- FT-Q组术侧峰值扭矩较非术侧显著降低(平均差-38.6 N·m,95%CI -55.7至-21.5,P<.001)。
- FT-Q组术侧平均功率和总做功均显著低于非术侧(P<.001),PT-Q组均无显著差异。
- PT-Q组术侧与非术侧在峰值扭矩、平均功率和总做功上均无显著差异。
核心结论
- FT-Q组术侧所有等速肌力变量均显著低于非术侧,而PT-Q组术侧与非术侧无显著差异。
研究设计与样本
- 队列研究,证据等级3级;2021年6月至2021年11月招募26例接受FT-Q或PT-Q移植ACLR的患者,术后超过1年进行等速膝关节伸展测试。
主要发现
- FT-Q组术侧峰值扭矩较非术侧降低(平均差±标准误,-38.6±8.3 N·m;95%CI -55.7至-21.5 N·m;P<.001;d=0.90)。
- PT-Q组术侧与非术侧峰值扭矩无显著差异(平均差±标准误,-7.3±7.7 N·m;95%CI -23.2至8.5 N·m;P=.348;d=0.20)。
- FT-Q组术侧平均功率低于非术侧(平均差±标准误,-53.6±13.4 W;95%CI -81.3至-26.9 W;P<.001;d=0.88),PT-Q组无显著差异(平均差±标准误,-4.1±12.4 W;95%CI -29.8至21.5 W;P=.742;d=0.07)。
- FT-Q组术侧总做功低于非术侧(平均差±标准误,-118.2±27.1 J;95%CI -174.3至-62.2 J;P<.001;d=0.96),PT-Q组无显著差异(平均差±标准误,-18.3±25.1 J;95%CI -70.2至33.6 J;P=.472;d=0.15)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Anterior cruciate ligament reconstruction (ACLR) using the quadriceps tendon is an increasingly popular technique. Both partial-thickness quadriceps tendon (PT-Q) and full-thickness quadriceps tendon (FT-Q) graft depths are employed. HYPOTHESIS/PURPOSE: This study was designed to assess isokinetic peak torque, average power, and total work during knee extension in patients with FT-Q or PT-Q grafts for ACLR. We hypothesized that both groups would show lower isokinetic values for the operated side, with greater deficits in the FT-Q group than in the PT-Q group. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: A total of 26 patients who underwent ACLR with either an FT-Q or PT-Q graft were recruited between June 2021 and November 2021. Patients underwent isokinetic knee extension testing at > 1 year after surgery. Mixed repeated-measures analysis of covariance with least square difference post hoc testing was used to determine significant differences or interactions for all variables. RESULTS: Peak torque was significantly lower for the operated limb than the nonoperated limb in the FT-Q group (mean difference [MD] ± standard error [SE], -38.6 ± 8.3 Nċm [95% CI, -55.7 to -21.5 Nċm]; P < .001; d = 0.90) but not in the PT-Q group (MD ± SE, -7.3 ± 7.7 Nċm [95% CI, -23.2 to 8.5 Nċm]; P = .348; d = 0.20). Similarly, average power for the operated limb was lower than that for the nonoperated limb in the FT-Q group (MD ± SE, -53.6 ± 13.4 W [95% CI, -81.3 to -26.9 W]; P < .001; d = 0.88) but not in the PT-Q group (MD ± SE, -4.1 ± 12.4 W [95% CI, -29.8 to 21.5 W]; P = .742; d = 0.07), and total work was lower for the operated limb compared with the nonoperated limb in the FT-Q group (MD ± SE, -118.2 ± 27.1 J [95% CI, -174.3 to -62.2 J]; P < .001; d = 0.96) but not in the PT-Q group (MD ± SE, -18.3 ± 25.1 J [95% CI, -70.2 to 33.6 J]; P = .472; d = 0.15). CONCLUSION: The FT-Q group showed significant deficits in the operated limb compared with the nonoperated limb for all isokinetic variables. In contrast, no significant differences were found between the nonoperated and operated limbs for the PT-Q group.
引用
- Letter MI, Parrino RL, Adams W, et al. The Associations Between Quadriceps Tendon Graft Thickness and Isokinetic Performance. Am J Sports Med. 2023. PMID: 36790220. doi:10.1177/03635465231152899
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。