文献速递关节外科运动医学

非骨水泥活动平台与骨水泥固定平台内侧单髁膝关节置换术的假体生存率相似但翻修原因不同:一项纳入2015例患者的长期人群队列研究

Similar Survivorship but Different Revision Reasons for Uncemented Mobile-Bearing and Cemented Fixed-Bearing Medial UKA: A Long-Term Population-Based Cohort Study of 2,015 Patients.
PubMed 文献 · J Bone Joint Surg Am · 2023-02-22

该研究纳入2015例内侧单髁膝关节置换术(UKA),平均随访8年、最长20年,分析假体生存率、翻修风险因素及翻修原因。结果显示15年生存率骨水泥固定平台(cemFB)92%、非骨水泥活动平台(uncemMB)91%、骨水泥活动平台(cemMB)80%(p=0.02);与cemFB相比,cemMB翻修风险更高(HR=1.9,95%CI 1.1-3.2;p=0.03)。作者认为假体设计和患者年龄是翻修风险因素,建议术者可考虑使用cemFB或uncemMB设计。

要点

  • 15年假体生存率:cemFB 92%,uncemMB 91%,cemMB 80%(p=0.02)。
  • 与cemFB相比,cemMB翻修风险更高(HR=1.9,95%CI 1.1-3.2;p=0.03)。
  • 年轻患者翻修风险高于≥70岁者:<60岁HR=1.9,60-69岁HR=1.6。

核心结论

  • 假体设计和患者年龄是内侧UKA翻修的风险因素。
  • 作者认为,与cemMB设计相比,cemFB或uncemMB设计具有更优的长期假体生存率,术者可考虑使用cemFB或uncemMB设计。
  • 作者指出,对于年轻患者(<70岁),uncemMB设计较cemFB设计无菌性松动风险更低,但代价是存在衬垫脱位风险。

研究设计与样本

  • 基于人群的长期队列研究,纳入2015例初次内侧UKA,平均随访8年(最长20年)。
  • 通过系统临床和影像学复查记录患者、假体及翻修细节。
  • 采用Cox比例风险模型分析生存率和翻修风险,采用竞争风险分析翻修原因。
  • 证据等级为预后Level III。

主要发现

  • 15年假体生存率:cemFB 92%,uncemMB 91%,cemMB 80%(p=0.02)。
  • 与cemFB相比,cemMB翻修风险更高(HR=1.9,95%CI 1.1-3.2;p=0.03)。
  • 15年时,骨水泥假体因无菌性松动的累积翻修频率更高(3%至4%,非骨水泥为0.4%;p<0.01)。
  • 15年时,cemMB因骨关节炎进展的累积翻修频率更高(9%,cemFB/uncemMB为2%至3%;p<0.05)。
  • 15年时,uncemMB因衬垫脱位的累积翻修频率更高(4%,cemMB为2%;p=0.02)。

关键数值与推荐

  • 与≥70岁患者相比,年轻患者翻修风险更高:<60岁HR=1.9(95%CI 1.2-3.0),60-69岁HR=1.6(95%CI 1.0-2.4);两者p<0.05。
  • 15年时,<60岁和60-69岁组因无菌性松动的累积翻修频率分别为3.2%和3.5%,≥70岁组为2.7%(p<0.05)。

临床怎么用

  • 作者认为,术者可考虑使用cemFB或uncemMB设计,因其长期假体生存率优于cemMB设计。
  • 作者指出,对于年轻患者(<70岁),uncemMB设计较cemFB设计无菌性松动风险更低,但代价是存在衬垫脱位风险。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Long-term survivorship and accurate characterization of revision reasons in unicompartmental knee arthroplasty (UKA) are limited by a lack of long-term data and standardized definitions of revision. The aim of this study was to identify survivorship, risk factors, and reasons for revision in a large cohort of medial UKAs with long-term follow-up (up to 20 years). METHODS: Patient, implant, and revision details for 2,015 primary medial UKAs (mean follow-up, 8 years) were recorded following systematic clinical and radiographic review. Survivorship and risk of revision were analyzed using Cox proportional hazards. Reasons for revision were analyzed using competing-risk analysis. RESULTS: Implant survivorship at 15 years was 92% for cemented fixed-bearing (cemFB), 91% for uncemented mobile-bearing (uncemMB), and 80% for cemented mobile-bearing (cemMB) UKAs (p = 0.02). When compared with cemFB, the risk of revision was higher for cemMB implants (hazard ratio [HR] = 1.9, 95% confidence interval [CI] = 1.1 to 3.2; p = 0.03). At 15 years, cemented implants had a higher cumulative frequency of revision due to aseptic loosening (3% to 4%, versus 0.4% for uncemented; p < 0.01), cemMB implants had a higher cumulative frequency of revision due to osteoarthritis progression (9% versus 2% to 3% for cemFB/uncemMB; p < 0.05), and uncemMB implants had a higher cumulative frequency of revision due to bearing dislocation (4% versus 2% for cemMB; p = 0.02). Compared with the oldest patients (≥70 years), younger patients had a higher risk of revision (<60 years: HR = 1.9, 95% CI = 1.2 to 3.0; 60 to 69 years: HR = 1.6, 95% CI = 1.0 to 2.4; p < 0.05 for both). At 15 years, there was a higher cumulative frequency of revision for aseptic loosening in these younger groups (3.2% and 3.5% versus 2.7% for ≥70 years; p < 0.05). CONCLUSIONS: Implant design and patient age were risk factors for revision of medial UKA. The findings from this study suggest that surgeons should consider using cemFB or uncemMB designs because of their superior long-term implant survivorship compared with cemMB designs. Additionally, for younger patients (<70 years), uncemMB designs had a lower risk of aseptic loosening than cemFB designs at the expense of a risk of bearing dislocation. LEVEL OF EVIDENCE: Prognostic Level III . See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Tay ML, Bolam SM, Maxwell AR, et al. Similar Survivorship but Different Revision Reasons for Uncemented Mobile-Bearing and Cemented Fixed-Bearing Medial UKA: A Long-Term Population-Based Cohort Study of 2,015 Patients. J Bone Joint Surg Am. 2023. PMID: 36812351. doi:10.2106/JBJS.22.00686

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。