文献速递关节外科

多采集可变共振图像组合磁共振成像显示骨水泥髌骨假体固定显著差于股骨和胫骨假体:值得担忧的原因?

Significantly Worse Fixation of Cemented Patellar Components on Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Compared to Femoral and Tibial Components: A Cause for Concern?
PubMed 文献 · J Arthroplasty · 2023-02-18

回顾性分析279例因膝前痛或弥漫性膝痛在骨水泥后稳定型全膝关节置换术后至少6个月行金属伪影减少MRI的膝关节,评估髌骨、股骨和胫骨骨水泥-骨界面。髌骨假体骨水泥整合差和松动比例显著高于股骨和胫骨假体,膝前痛与髌骨骨水泥整合较差相关,女性预测整合更好,但需进一步研究。

要点

  • 骨水泥髌骨假体≥75%区域纤维组织的比例为50%,高于股骨的18%和胫骨的5%(P < .001)。
  • 髌骨假体骨水泥整合差的比例为18%,高于股骨的1%和胫骨的1%(P < .001)。
  • 膝前痛与髌骨骨水泥整合较差相关(P = .01),女性预测整合更好(P < .001)。

核心结论

  • 全膝关节置换术后髌骨骨水泥-骨界面质量差于股骨或胫骨假体界面。
  • 髌骨骨水泥-骨界面差可能是全膝关节置换术后膝前痛的来源,但需进一步研究。

研究设计与样本

  • 回顾性分析279例在全膝关节置换术后至少6个月因膝前痛或弥漫性膝痛行金属伪影减少MRI的膝关节。
  • 全膝关节置换为骨水泥后稳定型并行髌骨置换,使用同一植入物制造商。
  • 由接受过专科培训的资深肌肉骨骼放射科医生评估髌骨、股骨和胫骨的MRI骨水泥-骨界面及整合百分比。
  • 比较髌骨界面的分级和特征与股骨和胫骨,并使用回归分析确定髌骨整合与膝前痛的相关性。

主要发现

  • 髌骨假体≥75%区域为纤维组织的比例为50%,股骨为18%,胫骨为5%(P < .001)。
  • 髌骨假体骨水泥整合差的比例为18%,股骨为1%,胫骨为1%(P < .001)。
  • MRI显示髌骨假体松动的比例为8%,股骨为1%,胫骨为1%(P < .001)。
  • 膝前痛与髌骨骨水泥整合较差相关(P = .01),女性预测整合更好(P < .001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文结论指出髌骨骨水泥-骨界面差可能是全膝关节置换术后膝前痛的来源,但需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The etiology of anterior knee pain after total knee arthroplasty (TKA) remains unclear. Few studies have examined patellar fixation quality. The purpose of the present study was to evaluate the patellar cement-bone interface after TKA on magnetic resonance imaging (MRI) and to correlate the patella fixation grade with the incidence of anterior knee pain. METHODS: We retrospectively reviewed 279 knees undergoing metal artifact reduction MRI for either anterior or generalized knee pain at least 6 months after cemented, posterior-stabilized TKA with patellar resurfacing with one implant manufacturer. MRI cement-bone interfaces and percent-integration of the patella, femur, and tibia were assessed by a fellowship-trained senior musculoskeletal radiologist. The grade and character of the patella interface were compared to the femur and tibia. Regression analyses were used to determine the association between patella integration with anterior knee pain. RESULTS: There were more patellar components with ≥75% zones of fibrous tissue (50%) compared to the femur (18%) or tibia (5%) (P < .001). There were a greater number of patellar implants with poor cement integration (18%) compared to the femur (1%) or tibia (1%) (P < .001). MRI findings showed more evidence of patellar component loosening (8%) compared to the femur (1%) or tibia (1%) (P < .001). Anterior knee pain was correlated with worse patella cement integration (P = .01), with women predicted to have better integration (P < .001). CONCLUSION: The quality of the patellar cement-bone interface after TKA is worse compared to the femoral or tibial component interface. Poor patellar cement-bone interface may be a source of anterior knee pain after TKA, but further investigation is required.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Debbi EM, Mayman DJ, Sapountzis N, et al. Significantly Worse Fixation of Cemented Patellar Components on Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Compared to Femoral and Tibial Components: A Cause for Concern? J Arthroplasty. 2023. PMID: 36801475. doi:10.1016/j.arth.2023.02.035

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。