一体式凹槽钛锥形柄用于Paprosky IIIa、IIIb和IV型股骨骨缺损的临床与影像学结果
这项多中心回顾性观察研究纳入81例Paprosky IIIa、IIIb或IV型股骨骨缺损患者,评估一体式凹槽钛锥形柄的中位29个月随访结果。中位下沉1.4毫米,未急性翻修的柄均稳定无松动,2年全因柄生存率95.1%、4年87.1%,排除感染后2年和4年均为98.8%。
要点
- 中位下沉1.4毫米(范围0至15.0),16例(23.9%)下沉超过5毫米,3例(4.5%)超过10毫米。
- 10髋(12.3%)再手术,仅5例(6.2%)柄被取出,其中4例因假体周围感染、1例因髋臼翻修手术暴露。
- 全因柄生存率2年95.1%、4年87.1%;排除感染后2年和4年均为98.8%。
核心结论
- 一体式凹槽钛锥形柄在严重股骨骨缺损的复杂股骨重建病例中,中位29个月随访时显示出令人鼓舞的临床和影像学结果。
研究设计与样本
- 多中心回顾性观察研究,纳入所有接受一体式凹槽钛锥形柄且影像学随访至5年的全髋关节置换患者,仅纳入股骨Paprosky IIIa、IIIb和IV型,共检查81个一体式凹槽钛锥形柄,中位临床随访29个月(范围18至58)。
主要发现
- 中位下沉1.4毫米(范围0至15.0),16个柄(23.9%)下沉大于5毫米,3个柄(4.5%)下沉大于10毫米。
- 所有未急性翻修的柄在末次随访时均表现稳定,无松动证据。
- 10髋(12.3%)需要再手术,其中仅5个柄(6.2%)被取出,4个因假体周围感染、1个因髋臼翻修时手术暴露。
- Kaplan-Meier分析显示全因柄生存率2年为95.1%、4年为87.1%;排除感染原因的柄生存率在2年和4年均为98.8%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Modern fluted titanium-tapered stems (FTTS) have been increasingly utilized to achieve primary stability in conversion and revision total hip arthroplasty with major femoral bone loss. This study sought to determine the radiographic and clinical outcomes of a monoblock FTTS in patients who had major femoral bone loss. METHODS: A multicenter retrospective observational study of all total hip arthroplasty patients who received a monoblock FTTS who had up to 5-year radiographic follow-up was conducted. Only patients with femoral Paprosky classifications of IIIa, IIIb, and IV were included. Eighty-one monoblock FTTS were examined. Median clinical follow-up was 29 months (range, 18 to 58). Stem subsidence and loosening were assessed on most recent radiographs. All-cause revisions and stem survivals were assessed. RESULTS: Median subsidence was 1.4 millimeters (mm) (range, 0 to 15.0). Sixteen (23.9%) and 3 (4.5%) stems had subsidence greater than 5 and 10 mm, respectively. All stems not acutely revised appeared stable, without evidence of loosening, at latest follow-up. Ten hips (12.3%) required reoperations. Of these, only 5 (6.2%) stems were removed; 4 due to periprosthetic joint infection and 1 for surgical exposure during acetabular revision. Kaplan-Meier analyses yielded an all-cause stem survivorship of 95.1% at 2-years and 87.1% at 4-years. Stem survivorships excluding septic causes was 98.8% at both 2 and 4 years. CONCLUSION: Monoblock FTTS in complex femoral reconstruction cases showed encouraging clinical and radiographic results in patients who had severe femoral bone loss at median 29 months follow-up.
引用
- Passano B, Oakley CT, Lutes WB, et al. Clinical and Radiographic Outcomes of a Monoblock Fluted Titanium-Tapered Stem for Paprosky IIIa, IIIb, and IV Femoral Bone Defects. J Arthroplasty. 2023. PMID: 36731584. doi:10.1016/j.arth.2023.01.034
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。