文献速递关节外科

后路全髋关节置换术中大头径与部分双动轴承与不稳定性降低相关

Large Femoral Heads and Select Dual-Mobility Bearings Are Associated With Reduced Instability in Contemporary Posterior Approach Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2023-02-13

该研究回顾性分析1511例连续初次后路全髋关节置换术,评估股骨头直径增大、聚乙烯衬里变薄及双动轴承引入后脱位率的变化。总体脱位率为0.98%,≥40毫米股骨头使用比例从4%增至51%,脱位率从1.4%降至0.7%(P=0.279);双动轴承或≥40毫米股骨头患者无脱位发生(P=0.007)。

要点

  • 总体脱位率为0.98%,14例脱位中13例为女性(P=0.005)。
  • ≥40毫米股骨头使用比例从4%增至51%,脱位率从1.4%降至0.7%(P=0.279)。
  • 双动轴承或≥40毫米股骨头患者无脱位发生(P=0.007)。

核心结论

  • 在当代后路全髋关节置换术中,在给定髋臼杯尺寸下最大化股骨头直径与脱位率降低相关。
  • 结果提示双动关节面应保留用于高风险患者或无法使用40毫米股骨头的患者。

研究设计与样本

  • 回顾性连续病例系列,纳入1511例连续初次全髋关节置换术,无对照组。
  • 队列中女性占57%,平均年龄62岁(范围13至93岁),平均体重指数31 kg/m2(范围13至54)。
  • 采用时间序列分析方法评估股骨头增大、聚乙烯衬里变薄及双动轴承引入后的变化。

主要发现

  • 总体脱位率为0.98%。
  • 股骨头尺寸≥40毫米的使用比例从2010至2016年的4%增至2017至2021年的51%,脱位率从1.4%降至0.7%(P=0.279)。
  • 双动轴承或≥40毫米股骨头的患者中无脱位发生(P=0.007)。
  • 14例脱位中12例发生在头杯比<0.7的病例(P=0.013)。
  • 14例脱位中13例发生在女性(P=0.005)。

临床怎么用

  • 作者认为,在给定髋臼杯尺寸下最大化股骨头直径可降低现代后路全髋关节置换术的脱位率。
  • 作者建议,双动关节面应保留用于高风险患者或无法使用40毫米股骨头的患者。

局限性

  • 证据等级为IV级,连续病例系列,无对照组。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Postoperative dislocation is considered the main drawback of posterior approach total hip arthroplasty (THA). Thinner highly cross-linked polyethylene and dual-mobility bearings allow maximizing femoral head diameter per a given cup size. This study evaluated dislocation rates as large femoral head bearings were introduced into a practice over an 11-year period. METHODS: A total of 1,511 consecutive primary THAs were retrospectively reviewed. Demographics, implant sizes, femoral head-acetabular cup ratio, and dislocation status were collected from the electronic medical record. Data were evaluated using time series analysis techniques as larger femoral heads, thinner polyethylene liners, and dual-mobility bearings were introduced. The cohort was 57% women with mean age and body mass index of 62 years (range, 13 to 93) and 31 kg/m2 (range, 13 to 54), respectively. RESULTS: The overall dislocation rate was 0.98%. Use of femoral head sizes ≥ 40 millimeters increased from 4% in the years 2010 to 2016 to 51% in the years 2017 to 2021, correlating with a 50% reduction in dislocation rate from 1.4% to 0.7% (P = .279). Also, no dislocations occurred in patients who had dual-mobility bearings or ≥ 40-millimeter femoral heads (P = .007). Twelve of 14 dislocations occurred in cases with head-cup ratio < 0.7 (P = .013). Thirteen of 14 dislocations were in women (P = .005). CONCLUSION: Maximizing the femoral head diameter per given cup size correlated with a decrease in dislocation rate in modern posterior approach THA. Furthermore, these results suggest that dual-mobility articulations should be reserved for high-risk patients or patients in whom a 40-millimeter femoral head is not possible. LEVEL OF EVIDENCE: IV-consecutive case series; no control group.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Pitz-Gonçalves LI, Deckard ER, Meneghini RM, et al. Large Femoral Heads and Select Dual-Mobility Bearings Are Associated With Reduced Instability in Contemporary Posterior Approach Total Hip Arthroplasty. J Arthroplasty. 2023. PMID: 36791889. doi:10.1016/j.arth.2023.02.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。