文献速递关节外科

移动平台单髁膝关节置换术的股骨优先技术可减少植入物变异并早期改善功能与生存率

Femur-First Technique for Mobile Bearing Unicompartmental Knee Arthroplasty Results in Decreased Implant Variability and Early Improvements in Function and Survivorship.
PubMed 文献 · J Arthroplasty · 2023-02-15

单外科医生2007至2020年共430例移动平台单髁膝关节置换术(UKA),2012年后连续141例采用股骨优先(FF)技术,与此前连续147例胫骨优先(TF)技术对比;FF组聚乙烯更薄(3.4±0.7 mm 对 3.7±0.9 mm,P=0.002),5年无翻修生存率FF组98%对TF组94%(P=0.35),末次随访膝关节学会功能评分FF组更高(P<0.001)。

要点

  • FF技术聚乙烯厚度3.4±0.7 mm,TF技术3.7±0.9 mm(P=0.002)。
  • 5年无组件翻修生存率FF组98%对TF组94%(P=0.35)。
  • 末次随访膝关节学会功能评分FF组高于TF组(P<0.001)。

核心结论

  • 与传统TF技术相比,FF技术更保留骨量并改善影像学定位。
  • FF技术是移动平台UKA的替代方法,与植入物生存率和功能的改善相关。

研究设计与样本

  • 单外科医生2007至2020年共430例UKA,2012年后连续141例FF技术与此前连续147例TF技术对比。
  • 平均随访6年(范围2至13年),平均年龄63岁(范围23至92岁),共132名女性。
  • 术后X线片评估植入物定位,采用Kaplan-Meier曲线进行生存分析。

主要发现

  • FF组聚乙烯厚度3.4±0.7 mm,TF组3.7±0.9 mm(P=0.002)。
  • FF组94%病例的衬垫厚度为4 mm或以下。
  • 5年无组件翻修生存率FF组98%对TF组94%(P=0.35)。
  • 末次随访膝关节学会功能评分FF组高于TF组(P<0.001)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Higher failure rates of unicompartmental knee arthroplasty (UKA) are seen with lower surgical volume. Surgical techniques that introduce less variability improving implant positioning may lead to improved survivorship. A femur-first (FF) technique has been described, but survivorship data compared to traditional tibia-first (TF) technique are under-reported. We report the results of mobile-bearing UKA using the FF technique compared to the TF technique with emphasis on implant position and survivorship. METHODS: A total of 430 UKAs were performed by a single surgeon between 2007 and 2020. After 2012, there were 141 consecutive UKAs performed with the FF technique which were compared with 147 consecutive UKAs prior. Mean follow-up was 6 years (range, 2 to 13 years), average age was 63 years (range, 23 to 92 years), and there were 132 women. Postoperative radiographs were reviewed to determine implant positioning. Survivorship analyses were performed using Kaplan-Meier curves. RESULTS: The FF resulted in significantly thinner polyethylene (3.4 ± 0.7 mm versus 3.7 ± 0.9 mm) (P = .002) and 4 mm or less bearing thickness in 94% of cases. At 5 years, there was an early trend toward improved survivorship free from component revision (98% for the FF group and 94% for the TF [P = .35]). The FF cohort had higher Knee Society Functional scores at final follow-up (P < .001). CONCLUSION: Compared to traditional TF technique, the FF was more bone-preserving and improved radiographic positioning. The FF technique is an alternative method for mobile-bearing UKA and was associated with an improvement in implant survivorship and function.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Labott JR, Carlson SW, Lee SH, et al. Femur-First Technique for Mobile Bearing Unicompartmental Knee Arthroplasty Results in Decreased Implant Variability and Early Improvements in Function and Survivorship. J Arthroplasty. 2023. PMID: 36796707. doi:10.1016/j.arth.2023.02.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。