文献速递关节外科

一项随机对照试验:比较新型与成熟非骨水泥旋转平台全膝关节置换术后两年股骨与胫骨假体移行情况

A randomized controlled trial comparing two-year postoperative femoral and tibial migration of a new and an established cementless rotating platform total knee arthroplasty.
PubMed 文献 · Bone Joint J · 2023-01-01

该随机对照放射立体测量分析(RSA)试验纳入61例全膝关节置换(TKA),比较非骨水泥旋转平台Attune与Low Contact Stress(LCS)假体股骨与胫骨部件的移行,术后两年Attune股骨部件最大总点运动(MTPM)显著小于LCS,胫骨部件MTPM无显著差异,两种设计在术后第二年均稳定,预期无菌性松动风险低。

要点

  • 术后两年Attune股骨部件平均MTPM为0.92 mm(95%CI 0.75-1.11),LCS为1.72 mm(95%CI 1.47-2.00),差异有统计学意义(p<0.001)。
  • 术后两年胫骨部件平均MTPM Attune为1.11 mm(95%CI 0.94-1.30),LCS为1.17 mm(95%CI 0.99-1.36),差异无统计学意义(p=0.447)。
  • Attune组静息疼痛评分在整个随访期显著低于LCS组;术后三个月Attune组KOOS-PS、牛津膝关节评分及NRS-活动评分显著更优。

核心结论

  • 非骨水泥旋转平台Attune股骨部件平均MTPM显著小于LCS设计,主要体现在下沉、后倾及内旋显著更少。
  • 胫骨部件平均MTPM无显著差异;术后第二年两种设计假体均稳定,预期无菌性松动风险低。

研究设计与样本

  • 随机对照RSA试验,共分析61例全膝关节置换(TKA)。
  • RSA检查于术后1天及3、6、12、24个月进行,分析最大总点运动(MTPM)、平移与旋转。
  • 临床与患者报告结局(PROMs)于术前及术后6周、3、6、12、24个月收集,采用线性混合效应模型进行统计分析。

主要发现

  • 术后两年Attune股骨部件平均MTPM为0.92 mm(95%CI 0.75-1.11),LCS为1.72 mm(95%CI 1.47-2.00),差异有统计学意义(p<0.001)。
  • Attune股骨部件下沉、前后倾斜(后倾)及内外旋转均显著少于LCS。
  • 术后两年胫骨部件平均MTPM Attune为1.11 mm(95%CI 0.94-1.30),LCS为1.17 mm(95%CI 0.99-1.36),差异无统计学意义(p=0.447)。
  • 术后第二年两种设计的股骨与胫骨部件移行速率均可忽略。
  • Attune组静息疼痛(NRS-静息)在整个随访期显著低于LCS组;术后三个月Attune组KOOS-PS、牛津膝关节评分及NRS-活动评分显著更优。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The primary aim of this study was to compare the migration of the femoral and tibial components of the cementless rotating platform Attune and Low Contact Stress (LCS) total knee arthroplasty (TKA) designs, two years postoperatively, using radiostereometric analysis (RSA) in order to assess the risk of the development of aseptic loosening. A secondary aim was to compare clinical and patient-reported outcome measures (PROMs) between the designs. METHODS: A total of 61 TKAs were analyzed in this randomized clinical RSA trial. RSA examinations were performed one day and three, six, 12, and 24 months postoperatively. The maximal total point motion (MPTM), translations, and rotations of the components were analyzed. PROMs and clinical data were collected preoperatively and at six weeks and three, six, 12, and 24 months postoperatively. Linear mixed effect modelling was used for statistical analyses. RESULTS: The mean MTPM two years postoperatively (95% confidence interval (CI)) of the Attune femoral component (0.92 mm (0.75 to 1.11)) differed significantly from that of the LCS TKA (1.72 mm (1.47 to 2.00), p < 0.001). The Attune femoral component subsided, tilted (anteroposteriorly), and rotated (internal-external) significantly less. The mean tibial MTPM two years postoperatively did not differ significantly, being 1.11 mm (0.94 to 1.30) and 1.17 mm (0.99 to 1.36, p = 0.447) for the Attune and LCS components, respectively. The rate of migration in the second postoperative year was negligible for the femoral and tibial components of both designs. The mean pain-at-rest (numerical rating scale (NRS)-rest) in the Attune group was significantly less compared with that in the LCS group during the entire follow-up period. At three months postoperatively, the Knee injury and Osteoarthritis Outcome Physical Function Shortform score, the Oxford Knee Score, and the NRS-activity scores were significantly better in the Attune group. CONCLUSION: The mean MTPM of the femoral components of the cementless rotating platform Attune was significantly less compared with that of the LCS design. This was reflected mainly in significantly less subsidence, posterior tilting, and internal rotation. The mean tibial MTPMs were not significantly different. During the second postoperative year, the components of both designs stabilized and low risks for the development of aseptic loosening are expected.Cite this article: Bone Joint J 2023;105-B(2):148-157.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Koster LA, Rassir R, Kaptein BL, et al. A randomized controlled trial comparing two-year postoperative femoral and tibial migration of a new and an established cementless rotating platform total knee arthroplasty. Bone Joint J. 2023. PMID: 36722052. doi:10.1302/0301-620X.105B2.BJJ-2022-0414.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。