三至六份组织标本对诊断假体周围关节感染最为准确

Three to six tissue specimens for histopathological analysis are most accurate for diagnosing periprosthetic joint infection.
PubMed 文献 · Bone Joint J · 2023-01-01

该回顾性诊断研究纳入2015年1月至2018年7月间119例全髋或全膝关节置换翻修术患者,取假体周围膜和假包膜多份标本行组织病理学分析,依据IDSA 2013、ICM 2018和EBJIS 2021标准定义PJI。基于EBJIS标准(排除组织学),46例(39%)被归类为感染,五份组织标本的敏感度为76.5%(95%CI 67.6至81.4),特异度为86.8%(95%CI 81.3至93.5)。作者结论认为翻修关节置换术时应采集三至六份假体周围膜和假包膜组织标本并由经验丰富的病理学家分析。

要点

  • 基于EBJIS标准(排除组织学),46例(39%)患者被归类为感染。
  • 四至六份标本的Youden指数最高:四份0.631、五份0.634、六份0.632。
  • 五份组织标本的敏感度为76.5%(95%CI 67.6至81.4),特异度为86.8%(95%CI 81.3至93.5)。

核心结论

  • 作者结论认为,翻修关节置换术时应采集三至六份假体周围膜和假包膜组织标本,并由在判读假体周围组织方面经验丰富且技术娴熟的病理学家进行分析。

研究设计与样本

  • 回顾性诊断研究,纳入2015年1月至2018年7月间全髋或全膝关节置换翻修术后患者119例,取假体周围膜和假包膜多份标本行组织病理学分析。
  • 依据IDSA 2013标准、ICM 2018标准和EBJIS 2021标准定义PJI,采用混合效应逻辑回归模型计算组织学诊断的敏感度和特异度,应用Youden指数确定最佳组织标本份数。

主要发现

  • 基于EBJIS标准(排除组织学),46例(39%)患者被归类为感染。
  • 四至六份标本的Youden指数最高:四份0.631、五份0.634、六份0.632。
  • 五份组织标本的敏感度为76.5%(95%CI 67.6至81.4),特异度为86.8%(95%CI 81.3至93.5),阳性预测值为66.0%(95%CI 53.2至78.7),阴性预测值为84.3%(95%CI 79.4至89.3)。
  • 以组织标本份数为函数的曲线下面积(AUC)计算为0.81。
  • 应用ICM和IDSA标准(排除组织学),分别有40例(34%)和32例(27%)患者被归类为感染;三至五份标本的Youden指数最高(ICM:三份0.648、四份0.651、五份0.649;IDSA:三份0.627、四份0.629、五份0.625)。

关键数值与推荐

  • 基于EBJIS标准(排除组织学),46例(39%)患者被归类为感染;五份组织标本的敏感度为76.5%(95%CI 67.6至81.4),特异度为86.8%(95%CI 81.3至93.5)。
  • 应用ICM标准(排除组织学),40例(34%)患者被归类为感染,三至五份标本的Youden指数最高:三份0.648、四份0.651、五份0.649。
  • 应用IDSA标准(排除组织学),32例(27%)患者被归类为感染,三至五份标本的Youden指数最高:三份0.627、四份0.629、五份0.625。

临床怎么用

  • 作者结论认为,翻修关节置换术时应采集三至六份假体周围膜和假包膜组织标本,并由在判读假体周围组织方面经验丰富且技术娴熟的病理学家进行分析。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: The aim of this study was to evaluate the optimal deep tissue specimen sample number for histopathological analysis in the diagnosis of periprosthetic joint infection (PJI). METHODS: In this retrospective diagnostic study, patients undergoing revision surgery after total hip or knee arthroplasty (n = 119) between January 2015 and July 2018 were included. Multiple specimens of the periprosthetic membrane and pseudocapsule were obtained for histopathological analysis at revision arthroplasty. Based on the Infectious Diseases Society of America (IDSA) 2013 criteria, the International Consensus Meeting (ICM) 2018 criteria, and the European Bone and Joint Infection Society (EBJIS) 2021 criteria, PJI was defined. Using a mixed effects logistic regression model, the sensitivity and specificity of the histological diagnosis were calculated. The optimal number of periprosthetic tissue specimens for histopathological analysis was determined by applying the Youden index. RESULTS: Based on the EBJIS criteria (excluding histology), 46 (39%) patients were classified as infected. Four to six specimens showed the highest Youden index (four specimens: 0.631; five: 0.634; six: 0.632). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of five tissue specimens were 76.5% (95% confidence interval (CI) 67.6 to 81.4), 86.8% (95% CI 81.3 to 93.5), 66.0% (95% CI 53.2 to 78.7), and 84.3% (95% CI 79.4 to 89.3), respectively. The area under the curve (AUC) was calculated with 0.81 (as a function of the number of tissue specimens). Applying the ICM and IDSA criteria (excluding histology), 40 (34%) and 32 (27%) patients were categorized as septic. Three to five specimens had the highest Youden index (ICM 3: 0.648; 4: 0.651; 5: 0.649) (IDSA 3: 0.627; 4: 0.629; 5: 0.625). CONCLUSION: Three to six tissue specimens of the periprosthetic membrane and pseudocapsule should be collected at revision arthroplasty and analyzed by a pathologist experienced and skilled in interpreting periprosthetic tissue.Cite this article: Bone Joint J 2023;105-B(2):158-165.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Sigmund IK, Yeghiazaryan L, Luger M, et al. Three to six tissue specimens for histopathological analysis are most accurate for diagnosing periprosthetic joint infection. Bone Joint J. 2023. PMID: 36722061. doi:10.1302/0301-620X.105B2.BJJ-2022-0859.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。