文献速递关节外科

血浆D-二聚体在假体周围关节感染诊断中非劣于血清C反应蛋白

Plasma D-Dimer Is Noninferior to Serum C-Reactive Protein in the Diagnosis of Periprosthetic Joint Infection.
PubMed 文献 · J Bone Joint Surg Am · 2023-02-09

这项前瞻性研究纳入502例髋或膝关节翻修术患者,按改良2018年国际共识会议(ICM)标准定义假体周围关节感染(PJI),术前检测血浆D-二聚体、ESR、CRP和纤维蛋白原。412例分析患者中,无症状组317例(76.9%),PJI组95例(23.1%)。血浆D-二聚体在诊断PJI方面非劣于血清CRP和ESR,可能作为翻修全关节置换术患者筛查的有用辅助手段。

要点

  • D-二聚体诊断PJI的AUC为0.860,敏感度81.3%,特异度81.7%。
  • CRP诊断PJI的AUC为0.862,敏感度90.4%,特异度70.0%。
  • 对惰性微生物所致感染,D-二聚体敏感度最高达93.8%。

核心结论

  • 血浆D-二聚体在诊断PJI方面非劣于血清CRP和ESR,可能作为翻修全关节置换术患者筛查的有用辅助手段。

研究设计与样本

  • 前瞻性研究纳入502例接受髋或膝关节翻修术的患者,最终412例纳入分析。
  • PJI按改良版2018年国际共识会议(ICM)标准定义,术前检测血浆D-二聚体、ESR、CRP和纤维蛋白原。
  • 采用受试者工作特征曲线评估各标志物诊断PJI的效能,并用Bonferroni校正进行两两比较以确定曲线下面积(AUC)差异是否显著。

主要发现

  • 412例患者中,317例(76.9%)无感染(无菌组),95例(23.1%)存在感染(PJI组)。
  • D-二聚体诊断PJI的AUC为0.860,敏感度81.3%,特异度81.7%。
  • CRP诊断PJI的AUC为0.862,敏感度90.4%,特异度70.0%。
  • ESR诊断PJI的AUC为0.833,敏感度73.9%,特异度85.2%。
  • 纤维蛋白原诊断PJI的AUC为0.798,敏感度74.7%,特异度75.4%;4种标志物诊断PJI的准确度相当(所有p > 0.05)。

关键数值与推荐

  • D-二聚体诊断惰性微生物所致感染的敏感度最高,为93.8%。

临床怎么用

  • 作者认为血浆D-二聚体在诊断PJI方面非劣于血清CRP和ESR,可能作为翻修全关节置换术患者筛查的有用辅助手段。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: No single test has demonstrated absolute accuracy in the diagnosis of periprosthetic joint infection (PJI). Serological markers are often used as screening tools in the workup of patients with suspected PJI. This study aimed to determine the diagnostic utility of plasma D-dimer for PJI in a variety of clinical scenarios. METHODS: This prospective study enrolled 502 patients undergoing revision hip or knee arthroplasty. PJI was defined per a modified version of the 2018 International Consensus Meeting (ICM) criteria. Plasma D-dimer, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), and fibrinogen were measured preoperatively. Receiver operating characteristic curves were used to assess the utility of each biomarker in the diagnosis of PJI. Pairwise comparison with Bonferroni correction was performed to determine whether the differences in areas under the curve (AUCs) between the markers were significant. RESULTS: Of the 412 patients included, 317 (76.9%) did not have an infection (aseptic group) and 95 (23.1%) had an infection (PJI group). All 4 serological markers, D-dimer (AUC, 0.860; sensitivity, 81.3%; specificity, 81.7%), CRP (AUC, 0.862; sensitivity, 90.4%; specificity, 70.0%), ESR (AUC, 0.833; sensitivity, 73.9%; specificity, 85.2%), and fibrinogen (AUC, 0.798; sensitivity, 74.7%; specificity, 75.4%), demonstrated comparable accuracy for the diagnosis of PJI (all p > 0.05). When examining the performance of the different inflammatory markers in diagnosing infection caused by indolent organisms, D-dimer demonstrated the highest sensitivity at 93.8%. CONCLUSIONS: We found that plasma D-dimer was noninferior to serum CRP and ESR in the diagnosis of PJI and may be a useful adjunct when screening patients undergoing revision total joint arthroplasty. LEVEL OF EVIDENCE: Diagnostic Level II . See Instructions for Authors for a complete description of levels of evidence.

来源:J Bone Joint Surg Am,查看原文。版权归原作者所有。

引用

  1. Tarabichi S, Goh GS, Baker CM, et al. Plasma D-Dimer Is Noninferior to Serum C-Reactive Protein in the Diagnosis of Periprosthetic Joint Infection. J Bone Joint Surg Am. 2023. PMID: 36758110. doi:10.2106/JBJS.22.00784

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。