文献速递关节外科

耻骨联合至骶尾关节距离与其它脊柱骨盆测量指标相关性差

Pubic Symphysis to Sacrococcygeal Joint: A Poor Correlate to Other Spinopelvic Measurements.
PubMed 文献 · J Arthroplasty · 2023-02-07

该回顾性研究纳入250例初次全髋关节置换术前患者,测量耻骨联合上缘至骶尾关节距离(PSCD)与骨盆倾斜角、骶骨倾斜角、骨盆入射角和腰椎前凸的相关性。结果显示PSCD与上述指标相关性均为弱或极弱,尽管观察者间信度强,PSCD不能可靠替代髋脊柱关系评估。

要点

  • PSCD与骨盆倾斜角、骶骨倾斜角、骨盆入射角、腰椎前凸的相关性均为弱或极弱。
  • 男性骨盆入射角与PSCD相关性无统计学意义(r=-0.04,P=0.70)。
  • 所有测量指标的观察者间信度均为强。

核心结论

  • PSCD在男女中与所有评估的侧位腰椎影像学指标均呈弱相关,尽管观察者间信度强,PSCD不能可靠作为评估髋脊柱关系的替代指标。

研究设计与样本

  • 回顾性评估250例连续接受全髋关节置换术且有术前仰卧位骨盆正位和腰椎侧位X线片的患者,平均年龄68岁(范围42至89),女性占61%,平均体重指数30 kg/m2(范围19至52),由两名评估者测量PSCD、骨盆倾斜角、骶骨倾斜角、骨盆入射角和腰椎前凸,计算观察者间信度及PSCD与各指标的相关系数。

主要发现

  • PSCD与骨盆倾斜角的相关系数男性为-0.30(P<.01),女性为-0.46(P<.01)。
  • PSCD与骶骨倾斜角的相关系数男性为0.27(P<.01),女性为0.22(P<.01)。
  • PSCD与骨盆入射角的相关系数男性为-0.04(P=.70),女性为-0.19(P=.02)。
  • PSCD与腰椎前凸的相关系数男性为0.45(P<.01),女性为0.30(P<.01)。
  • 所有测量指标的观察者间信度均评为强。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The hip-spine relationship is increasingly recognized as critical for optimizing stability following total hip arthroplasty (THA). However, these measurements are not routinely obtained during THA workup. It has been suggested that insight can be gained from supine antero-posterior pelvis radiograph, measuring the distance from the superior border of the pubic symphysis to the sacro-coccygeal joint (PSCD). This study assessed the correlation between PSCD and lateral lumbar radiographic metrics in a cohort of preoperative THA patients. METHODS: We retrospectively evaluated 250 consecutive patients who underwent THA with preoperative supine antero-posterior pelvis and lateral lumbar radiographs. The mean age was 68 years (range, 42 to 89), 61% were women, and the mean body mass index was 30 kg/m2 (range, 19 to 52). Two reviewers measured PSCD, pelvic tilt (PT), sacral slope (SS), pelvic incidence (PI), and lumbar lordosis (LL). Inter-observer reliability was calculated for all measurements, and correlation coefficients were calculated for PSCD with respect to PT, SS, PI, and LL. RESULTS: Correlations between PSCD and lumbar radiographic metrics were all statistically significant, except for PI in men but graded as "weak" or "very weak" for men and women, respectively, as follows: PT = -0.30 (P < .01) and -0.46 (P < .01); SS = 0.27 (P < .01) and 0.22 (P < .01); PI = -0.04 (P = .70) and -0.19 (P = .02); and LL = 0.45 (P < .01) and 0.30 (P < .01). Inter-observer reliability was graded as "strong" for every metric. CONCLUSION: The PSCD was weakly correlated with all evaluated lateral lumbar radiographic metrics in both sexes, despite strong inter-observer reliability. Therefore, PSCD cannot reliably serve as a proxy for evaluating the hip-spine relationship.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Labott JR, Smith JH, Mara KC, et al. Pubic Symphysis to Sacrococcygeal Joint: A Poor Correlate to Other Spinopelvic Measurements. J Arthroplasty. 2023. PMID: 36754336. doi:10.1016/j.arth.2023.01.052

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。