既往硬件存留患者行转换全膝关节置换术的并发症、假体生存率与功能结局
回顾2009年1月至2019年12月共148例既往有内固定物存留行全膝关节置换术的患者,平均随访60个月,并发症率18.9%。股四头肌剪开附加内侧髌旁关节切开与更高并发症、假体失败及更低VR-12心理评分相关;硬件取出与保留、单切口与多切口与并发症或假体失败无关联;取出全部硬件较保留全部硬件VR-12心理评分显著更高。
要点
- 148例既往硬件存留行TKA患者并发症率为18.9%(28/148),平均随访60个月。
- 股四头肌剪开与更高并发症(OR 20.7)、假体失败(OR 13.9)及更低VR-12心理评分(-14.8)相关。
- 取出全部硬件较保留全部硬件VR-12心理评分显著更高(+7.3)。
核心结论
- 既往硬件存留行TKA时,采用更限制性假体或股四头肌剪开与更多并发症、假体失败及更低VR-12心理评分相关,可能反映手术难度而非手术入路。
- 硬件取出或保留与并发症或假体失败无关联,但取出全部硬件较保留全部硬件与一般健康结局改善相关。
研究设计与样本
- 回顾性队列研究,纳入2009年1月至2019年12月期间既往有硬件存留行全膝关节置换术的患者148例,平均随访60个月(范围24-223个月)。
- 采用单因素和多因素分析研究因素与手术相关并发症、假体失败及功能结局的相关性。
- 证据等级IV,无对照的队列研究。
主要发现
- 并发症率为18.9%(28/148)。
- 股四头肌剪开附加内侧髌旁关节切开与更高并发症(OR 20.7,P<0.05)、假体失败(OR 13.9,P<0.05)及更低VR-12心理评分(-14.8,P<0.05)相关。
- 硬件取出与保留、单切口与多切口与并发症或假体失败无关联。
- 取出全部硬件较保留全部硬件VR-12心理评分显著更高(+7.3,P<0.05)。
局限性
- 证据等级IV,无对照的队列研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: End-stage knee osteoarthritis with retained periarticular hardware is a frequent scenario. Conversion total knee arthroplasty (TKA) leads to excellent outcomes, but poses unique challenges. The evidence supporting retention versus removal of hardware during TKA is controversial. METHODS: Patients who underwent TKA with prior hardware between January 2009 and December 2019 were identified. A total of 148 patients underwent TKA with prior hardware. The mean follow-up was 60 months (range, 24-223). Univariate and multivariable analyses were used to study correlations among factors and surgical-related complications, prosthesis failures, and functional outcomes. RESULTS: The complication rate was 28 of 148 (18.9%). The use of a quadriceps snips in addition to a medial parapatellar arthrotomy was associated with a higher complication (odds ratio: 20.7, P < .05), implant failures (odds ratio: 13.9, P < .05), and lower the Veterans Rand 12 Mental Score (VR-12 MS) (-14.8, P < .05). Hardware removal versus retention and use of single versus multiple incisions were not associated with complications or prosthesis failures. Removal of all hardware was associated with significantly higher (+7.3, P < .05) VR-12 MS compared to retention of all hardware. CONCLUSIONS: TKA with prior hardware was associated with more complications, implant failures, and lower VR-12 MS when a more constrained construct or quadriceps snip was performed. This probably reflects the level of difficulty of the procedure rather than the surgical approach used. Hardware removal or retention was not associated with complications or implant failures; however, removal rather than retention of all prior hardware is associated with increased general health outcomes. LEVEL OF EVIDENCE: IV, cohort without control.
引用
- Apinyankul R, Hui AY, Hwang K, et al. Complications, Implant Survivorships, and Functional Outcomes of Conversion Total Knee Arthroplasty With Prior Hardware. J Arthroplasty. 2023. PMID: 36758842. doi:10.1016/j.arth.2023.01.049
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。