文献速递关节外科小儿骨科

发育性髋关节发育不良髋臼直径评估与三维模拟用于髋臼重建

Acetabular Diameter Assessment and Three-Dimensional Simulation for Acetabular Reconstruction in Dysplastic Hips.
PubMed 文献 · J Arthroplasty · 2023-02-09

这项回顾性研究纳入216例发育性髋关节发育不良(DDH)患者,测量髋臼内、外宽度并进行三维模拟与二维标准模板规划。结果显示髋臼外宽度较内宽度更准确预测实际髋臼杯尺寸,三维模拟在Crowe IV型中预测准确率显著高于二维模板规划(89.1% vs 60.9%,P=0.001),作者认为在严重畸形尤其Crowe IV型患者中可推荐三维模拟。

要点

  • 髋臼外宽度较内宽度更准确预测实际髋臼杯尺寸。
  • 三维模拟在Crowe IV型中预测髋臼杯尺寸准确率显著高于二维模板规划。
  • II型患者髋臼上外侧骨缺损需额外关注。

核心结论

  • 髋臼外宽度较髋臼内宽度更准确预测实际髋臼杯尺寸。
  • II型病例的髋臼上外侧骨缺损需要额外关注。
  • 与二维模板规划相比,三维模拟在严重畸形的发育性髋关节发育不良髋中预测实际髋臼杯尺寸更准确,作者认为可推荐用于这些选定病例,尤其是Crowe IV型患者。

研究设计与样本

  • 回顾性研究,纳入216例发育性髋关节发育不良病例。
  • 在通过髋臼窝中心的平面上测量髋臼内宽度和髋臼外宽度。
  • 进行三维模拟和二维标准模板规划,记录术中实际髋臼杯尺寸及 augment 使用情况。

主要发现

  • II、III、IV型病例中髋臼内宽度与实际使用髋臼杯尺寸相差13至14毫米,而髋臼外宽度相差0.2至3.6毫米。
  • 二维模板规划与三维模拟预测髋臼杯尺寸的准确率在Crowe I型(86.5% vs 76%,P=0.075)、II型(72.7% vs 51.5%,P=0.127)、III型(93.3% vs 66.7%,P=0.169)中相当。
  • 三维模拟在Crowe IV型中准确率显著更高(89.1% vs 60.9%,P=0.001)。
  • Augment和植骨在II型中的使用率(25%)显著高于其他型(0至6.5%)。

关键数值与推荐

  • II、III、IV型病例髋臼内宽度与实际髋臼杯尺寸差值为13至14毫米。
  • II、III、IV型病例髋臼外宽度与实际髋臼杯尺寸差值为0.2至3.6毫米。
  • Crowe I型二维模板规划准确率86.5% vs 三维模拟76%(P=0.075)。
  • Crowe II型二维模板规划准确率72.7% vs 三维模拟51.5%(P=0.127)。
  • Crowe III型二维模板规划准确率93.3% vs 三维模拟66.7%(P=0.169);Crowe IV型二维模板规划准确率60.9% vs 三维模拟89.1%(P=0.001)。

临床怎么用

  • 作者认为,与二维模板规划相比,三维模拟在严重畸形的发育性髋关节发育不良髋中预测实际髋臼杯尺寸更准确,可推荐用于这些选定病例,尤其是Crowe IV型患者。
  • 作者指出,II型病例的髋臼上外侧骨缺损需要额外关注。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to investigate the relationship between acetabular width, three-dimensional (3D) simulation, and surgical results in total hip arthroplasty patients who have developmental dysplasia of the hip (DDH). METHODS: This retrospective study included 216 DDH cases. Inner and outer acetabular width (OAW) was measured at the plane passing through the center of acetabular fossa. 3D simulation and 2D standard templating were performed. The actual cup size and the use of augments during surgery were recorded. Association among the indices and their distribution in different types of DDH were analyzed. RESULTS: A difference of 13 to 14 millimeters (mm) was found between the inner acetabular width and actual cup size used in type II, III, and IV cases, while the difference was 0.2 to 3.6 mm for OAW. The accuracy of 2D templating and 3D simulation in predicting cup size was comparable in Crowe type I (86.5 versus 76%, P = .075), type II (72.7 versus 51.5%, P = .127), and type III (93.3 versus 66.7%, P = .169). The 3D simulation was significantly more accurate in Crowe type IV (89.1% versus 60.9%, P = .001). Augments and bone grafts were significantly more commonly used in type II (25%) than in the other types (0 to 6.5%). CONCLUSION: OAW more accurately predicted actual cup size than inner acetabular width. The supero-lateral acetabular bone defects in type II cases require additional attention. Compared with 2D templating, 3D simulation is more accurate in predicting actual cup size in dysplastic hips with severe deformity and may be recommended in these selected cases, especially for Crowe IV patients.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Chen X, Li S, Liu X, et al. Acetabular Diameter Assessment and Three-Dimensional Simulation for Acetabular Reconstruction in Dysplastic Hips. J Arthroplasty. 2023. PMID: 36764404. doi:10.1016/j.arth.2023.01.067

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。