PubMed 文献 · J Arthroplasty · 2023-02-09

本研究纳入110例接受单侧初次全膝关节置换术的成人患者,使用可穿戴设备监测睡眠时长与觉醒,并每周完成匹兹堡睡眠质量指数问卷和视觉模拟量表疼痛评分。患者自报的睡眠质量(极差睡眠)在术后30天与疼痛评分相关,而监测或自报的睡眠时长与任何临床指标均不相关。

要点

  • 术后90天内患者自报睡眠质量先恶化后改善,至90天超过基线水平。
  • 术后30天自报「极差」睡眠者VAS疼痛评分显著差于自报「差」睡眠者。
  • 可穿戴设备记录的睡眠时长未变化,且与VAS评分无相关性。

核心结论

  • 患者自报的睡眠质量(极差睡眠)在术后30天与VAS疼痛评分相关良好,而监测或自报的睡眠时长与任何临床指标均不相关,似乎不是评估全膝关节置换术结局的有用指标。

研究设计与样本

  • 纳入体重指数<45的成人患者,接受单侧初次全膝关节置换术,共110例,其中女性占54.5%,平均年龄64岁(范围43-80岁)。
  • 患者佩戴监测设备追踪睡眠时长和睡眠中断(夜间至少起床一次),并每周完成匹兹堡睡眠质量指数问卷和视觉模拟量表疼痛评分。

主要发现

  • VAS评分术后下降。
  • 匹兹堡睡眠质量指数总体睡眠评分、睡眠数量和睡眠质量在术后前30天恶化,至90天改善并超过基线水平。
  • 记录的睡眠时长未变化,且记录与VAS评分在任何时间点均不相关。
  • 匹兹堡睡眠质量指数总体评分和睡眠数量与VAS不相关。
  • 术后30天,自报「极差」睡眠的患者VAS评分显著差于自报「差」睡眠的患者。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Sleep disturbances are common after total knee arthroplasty (TKA), yet literature examining sleep and postoperative pain remains sparse. With the use of wearable devices, convenient objective remote sleep monitoring is now possible. We aimed to measure patient sleep following TKA using validated questionnaires and wearable devices to compare sleep patterns to pain scores 90 days postoperatively. METHODS: Adult patients with body mass index < 45 undergoing unilateral primary TKA were enrolled. Patients wore a monitor, which tracked sleep duration and disturbances (getting up at least once during the night). They completed weekly Pittsburgh Sleep Quality Index (PSQI) questionnaires and visual analog scale (VAS) pain scores. Sleep patterns were compared with pain scores and sleep duration was compared with PSQI responses. RESULTS: There were 110 patients included with 54.5% women; average age was 64 years (range, 43-80). VAS scores decreased postoperatively. PSQI overall sleep scores, sleep quantity, and sleep quality worsened for the first 30 days then improved past baseline levels by 90 days. Recorded sleep duration did not change, and recordings did not correlate at any point with VAS scores. PSQI overall score and sleep quantity did not correlate with VAS. At 30 days postoperatively, patients reporting "very bad" sleep had significantly worse VAS scores than those reporting "bad" sleep. CONCLUSION: Patient-reported sleep quality (very bad sleep) correlated well with VAS pain score at 30 days, while sleep duration (monitored or patient-reported) did not correlate with any clinical measure and does not seem to be a useful metric in assessing TKA outcome.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Gibian JT, Bartosiak KA, Lucey BP, et al. Sleep Disturbances Following Total Knee Arthroplasty. J Arthroplasty. 2023. PMID: 36773659. doi:10.1016/j.arth.2023.01.066

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。