文献速递运动医学关节外科

挑战对人体肌腱同种异体移植物的认知:供者年龄、性别、身高和肌腱类型对生物力学特性的影响

Challenging the Perceptions of Human Tendon Allografts: Influence of Donor Age, Sex, Height, and Tendon on Biomechanical Properties.
PubMed 文献 · Am J Sports Med · 2023-01-03

研究对39例新鲜冷冻尸体下肢的9种肌腱(共332条)进行拉伸失败测试,分析供者年龄、性别、身高和肌腱类型对生物力学特性的影响。结果显示不同肌腱间力学特性差异显著,供者特征的影响较小且仅局限于跟腱、胫骨后肌腱和胫骨前肌腱。作者认为年龄仅对跟腱最大载荷有负面影响,对当前排除65岁以上供者的标准提出质疑。

要点

  • 不同肌腱间生物力学特性差异显著,供者特征的影响相对较小。
  • 供者性别、年龄和身高的显著影响仅见于跟腱、胫骨后肌腱和胫骨前肌腱。
  • 作者认为研究结果支持扩大用于前交叉韧带重建的肌腱范围并重新审视65岁以上供者排除标准。

核心结论

  • 不同人体肌腱的力学特性差异显著,供者年龄、性别和身高的影响相对较小、仅局限于特定肌腱且对不同肌腱影响各不相同。
  • 研究结果表明年龄仅对跟腱的最大载荷有负面影响,对在所有肌腱移植物中排除65岁以上供者的做法提出质疑。

研究设计与样本

  • 描述性实验室研究,取39例新鲜冷冻人体尸体下肢(35名供者,女13名、男22名;年龄49-99岁;身高57-85英寸[145-216 cm])的9种肌腱共332条进行分析。
  • 9种肌腱包括:跟腱、胫骨后肌腱、胫骨前肌腱、腓骨长肌腱、腓骨短肌腱、拇长屈肌腱、拇长伸肌腱、跖肌腱和趾长屈肌腱。
  • 肌腱接受拉伸加载至失败,测量横截面积、最大载荷、失败应变、极限抗拉强度和弹性模量,采用混合效应线性回归分析并校正供者年龄、性别、身高和体重。

主要发现

  • 肌腱间的力学特性存在显著差异,且差异幅度远大于供者特征的影响。
  • 供者性别、年龄和身高的显著影响仅见于跟腱、胫骨后肌腱和胫骨前肌腱,其余肌腱均未受影响。
  • 跟腱受供者变量影响最大:男性横截面积更大(β=15.45 mm²;Šidák校正P<.0001)。
  • 跟腱最大载荷随年龄每增加1岁而下降(β=-17.20 N/年;校正P=.0253)。
  • 跟腱横截面积(β=1.92 mm²/英寸;校正P<.0001)和最大载荷(β=86.40 N/英寸;校正P<.0001)随身高每增加1英寸而增大。

临床怎么用

  • 作者认为研究结果支持将更广泛的肌腱纳入前交叉韧带重建同种异体移植物,并建议重新审视当前排除65岁以上供者的标准。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The use of allograft tendons has increased for primary and revision anterior cruciate ligament reconstruction, but allograft supply is currently limited to a narrow range of tendons and donors up to the age of 65 years. Expanding the range of donors and tendons could help offset an increasing clinical demand. PURPOSE: To investigate the effects of donor age, sex, height, and specific tendon on the mechanical properties of a range of human lower leg tendons. STUDY DESIGN: Descriptive laboratory study. METHODS: Nine tendons were retrieved from 39 fresh-frozen human cadaveric lower legs (35 donors [13 female, 22 male]; age, 49-99 years; height, 57-85 inches [145-216 cm]) including: Achilles tendon, tibialis posterior and anterior, fibularis longus and brevis, flexor and extensor hallucis longus, plantaris, and flexor digitorum longus. Tendons underwent tensile loading to failure measuring cross-sectional area (CSA), maximum load, strain at failure, ultimate tensile strength, and elastic modulus. Results from 332 tendons were analyzed using mixed-effects linear regression, accounting for donor age, sex, height, and weight. RESULTS: Mechanical properties were significantly different among tendons and were substantially greater than the effects of donor characteristics. Significant effects of donor sex, age, and height were limited to specific tendons: Achilles tendon, tibialis posterior, and tibialis anterior. All other tendons were unaffected. The Achilles tendon was most influenced by donor variables: greater CSA in men (β = 15.45 mm2; Šidák adjusted P < .0001), decreased maximum load with each year of increased age (β = -17.20 N per year; adjusted P = .0253), and increased CSA (β = 1.92 mm2 per inch; adjusted P < .0001) and maximum load (β = 86.40 N per inch; adjusted P < .0001) with each inch of increased height. CONCLUSION: Mechanical properties vary significantly across different human tendons. The effects of donor age, sex, and height are relatively small, are limited to specific tendons, and affect different tendons uniquely. The findings indicate that age negatively affected only the Achilles tendon (maximum load) and challenge the exclusion of donors aged >65 years across all tendon grafts. CLINICAL RELEVANCE: The findings support including a broader range of tendons for use as allografts for anterior cruciate ligament reconstruction and reviewing the current exclusion criterion of donors aged >65 years.

来源:Am J Sports Med,查看原文。版权归原作者所有。

引用

  1. Ashton DM, Blaker CL, Hartnell N, et al. Challenging the Perceptions of Human Tendon Allografts: Influence of Donor Age, Sex, Height, and Tendon on Biomechanical Properties. Am J Sports Med. 2023. PMID: 36594505. doi:10.1177/03635465221143385

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。