文献速递关节外科

将高交联聚乙烯内衬骨水泥固定于固定良好的髋臼外壳行翻修全髋关节置换术的长期结果

Long-Term Outcomes of Cementing Highly Cross-Linked Polyethylene Liners Into Well-Fixed Acetabular Shells in Revision Total Hip Arthroplasty.
PubMed 文献 · J Arthroplasty · 2023-01-26

本研究回顾性分析单术者系列中48髋(47例)因翻修全髋关节置换术将高交联聚乙烯内衬骨水泥固定于固定良好的髋臼外壳,平均随访14年。Harris髋关节评分从术前58分改善至末次评估91分(P < .001),无菌性松动导致3例髋臼再翻修,假体生存率93.3%(95%CI 85.9-100%)。作者认为该技术在没有与预先植入外壳兼容的高交联聚乙烯内衬时可作为安全持久的选择。

要点

  • 平均随访14年,Harris髋关节评分从术前58分改善至末次91分(P < .001)。
  • 3例髋臼再翻修均因外壳无菌性松动,无任何再翻修的假体生存率为93.3%(95%CI 85.9-100%)。
  • 术后1例脱位经闭合复位成功,末次X线片示髋臼骨溶解显著减少(P < .001)。

核心结论

  • 将高交联聚乙烯内衬骨水泥固定于固定良好的髋臼外壳行翻修全髋关节置换术,在平均术后14年表现出优异的临床和影像学结果。
  • 作者认为,在没有与预先植入外壳兼容的高交联聚乙烯内衬时,该技术可作为安全持久的选择。

研究设计与样本

  • 回顾性单术者系列,评估52髋(51例)中满足至少10年随访的48髋(47例)。
  • 初次手术平均年龄53岁(范围32至72岁),平均随访14年(范围10至18年)。

主要发现

  • Harris髋关节评分从术前平均58分(范围23-81)改善至末次评估平均91分(范围45-100)(P < .001)。
  • 共3例髋臼再翻修,均因外壳无菌性松动。
  • 术后1例脱位,经闭合复位成功治疗。
  • 末次X线片显示髋臼骨溶解显著减少(P < .001)。
  • 无任何再翻修的假体生存率为93.3%(95%CI 85.9-100%)。

临床怎么用

  • 作者认为,在没有与预先植入外壳兼容的高交联聚乙烯内衬时,将高交联聚乙烯内衬骨水泥固定于固定良好的髋臼外壳可作为安全持久的选择。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Cementing a new liner into a secure, well-positioned metallic shell can be a less-invasive strategy in revision total hip arthroplasty (THA). This study aimed to report the mean 14-year outcomes of cementing highly cross-linked polyethylene (XLPE) liners into well-fixed acetabular shells in revision THAs. METHODS: This study reviewed a single-surgeon series of cementing XLPE liners into well-fixed acetabular components. Of the 52 hips (51 patients) evaluated, 48 hips (47 patients) that satisfied a minimum follow-up of 10 years were included. The Harris Hip score was used for clinical evaluation. Final hip radiographs were used to determine the extent of acetabular osteolysis and stability of the components. The mean age at index operation was 53 years (range, 32 to 72). The mean follow-up duration was 14 years (range, 10 to 18). RESULTS: The mean Harris Hip score improved from 58 points (range, 23-81) preoperatively to 91 points (range, 45-100) at the final evaluation (P < .001). A total of 3 acetabular rerevisions were performed, all for aseptic loosening of the outer shell. One postoperative dislocation occurred, but it was successfully treated with a closed reduction. Final radiographs showed a significant reduction in acetabular osteolysis (P < .001). Implant survivorship free from any rerevision was 93.3% (95% confidence interval, 85.9-100%) at 14 years. CONCLUSION: Cementing an XLPE liner into a well-fixed acetabular shell in revision THA demonstrated excellent clinical and radiographic outcomes at a mean of 14 years postoperatively. This technique could be a safe and durable option in the absence of XLPE liners compatible with preimplanted shells.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Cho K, Park CW, Jeong SJ, et al. Long-Term Outcomes of Cementing Highly Cross-Linked Polyethylene Liners Into Well-Fixed Acetabular Shells in Revision Total Hip Arthroplasty. J Arthroplasty. 2023. PMID: 36709880. doi:10.1016/j.arth.2023.01.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。