文献速递关节外科

全髋关节置换术中薄型高交联聚乙烯内衬联合大股骨头假体平均随访12.8年显示优异生存率和低磨损率

Thin highly cross-linked polyethylene liners combined with large femoral heads in primary total hip arthroplasty show excellent survival and low wear rates at a mean follow-up of 12.8 years.
PubMed 文献 · Bone Joint J · 2023-01-01

该单中心回顾性研究纳入55例使用高交联聚乙烯(HXLPE)内衬、36 mm钴铬股骨头及外径≤52 mm髋臼杯的行初次全髋关节置换术(THA)患者,平均随访12.8年全因翻修生存率为94.5%(95%CI 81.7%–97.2%),3例翻修均非因内衬磨损、骨折或脱位。22例影像学随访平均9.9年,平均线性内衬磨损0.085 mm(95%CI -0.086–0.257),体积磨损率11.097 mm³/年(95%CI -6.5–28.7)。作者认为使用36 mm股骨头配52 mm或更小髋臼杯的HXLPE内衬是安全的,中期随访生存率优异且线性及体积磨损率低。

要点

  • 55例初次THA使用HXLPE内衬、36 mm股骨头及≤52 mm髋臼杯,平均随访12.8年全因翻修生存率94.5%(95%CI 81.7%–97.2%)。
  • 3例翻修,均非因内衬磨损、骨折或脱位。
  • 22例影像学分析平均随访9.9年,平均线性磨损0.085 mm(95%CI -0.086–0.257),体积磨损率11.097 mm³/年(95%CI -6.5–28.7)。

核心结论

  • 使用36 mm股骨头配52 mm或更小髋臼杯的HXLPE内衬是安全的,中期随访生存率优异且线性及体积磨损率低。
  • 患者未因内衬并发症(如骨折、脱位或磨损)需行翻修手术。
  • 作者认为使用较大股骨头的优势超过使用薄型HXLPE内衬的潜在风险。

研究设计与样本

  • 单中心回顾性识别55例初次THA患者,使用HXLPE内衬、36 mm钴铬股骨头及外径≤52 mm髋臼杯。
  • 记录患者人口学资料、植入物信息、死亡及所有全因翻修。
  • 采用Cox回归和Kaplan-Meier生存分析确定全因及内衬相关翻修。
  • 55例中22例影像学随访至少7年,评估线性及体积磨损。

主要发现

  • 平均随访12.8年(10.9–18.7),全因翻修总体生存率94.5%(95%CI 81.7%–97.2%)。
  • 3例患者翻修,无一例因内衬磨损、骨折或脱位翻修。
  • 22例影像学分析平均随访9.9年(7.5–13.7),平均线性内衬磨损0.085 mm(95%CI -0.086–0.257)。
  • 体积磨损率11.097 mm³/年(95%CI -6.5–28.7)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

AIMS: Several short- and mid-term studies have shown minimal liner wear of highly cross-linked polyethylene (HXLPE) in total hip arthroplasty (THA), but the safety of using thinner HXLPE liners to maximize femoral head size remains uncertain. The objective of this study was to analyze clinical survival and radiological wear rates of patients with HXLPE liners, a 36 mm femoral head, and a small acetabular component with a minimum of ten years' follow-up. METHODS: We retrospectively identified 55 patients who underwent primary THA performed at a single centre, using HXLPE liners with 36 mm cobalt-chrome heads in acetabular components with an outer diameter of 52 mm or smaller. Patient demographic details, implant details, death, and all-cause revisions were recorded. Cox regression and Kaplan-Meier survival was used to determine all-cause and liner-specific revision. Of these 55 patients, 22 had a minimum radiological follow-up of seven years and were assessed radiologically for linear and volumetric wear. RESULTS: Overall survival rate for all-cause revision was 94.5% (95% confidence interval (CI) 81.7% to 97.2%) at a mean follow-up of 12.8 years (10.9 to 18.7). Three patients were revised, none for liner wear, fracture, or dissociation. A total of 22 patients were included in the radiological analysis (mean follow-up 9.9 years (7.5 to 13.7)). Mean linear liner wear was 0.085 mm (95% CI -0.086 to 0.257) and the volumetric wear rate was 11.097 mm3/year (95% CI -6.5 to 28.7). CONCLUSION: Using HXLPE liners with 36 mm heads in 52 mm acetabular components or smaller is safe, with excellent survival and low rates of linear and volumetric wear at medium-term follow-up. Patients did not require revision surgery for liner complications such as fracture, dissociation, or wear. Our results suggest that the advantages of using larger heads outweigh the potential risks of using thin HXLPE liners.Cite this article: Bone Joint J 2023;105-B(1):29-34.

来源:Bone Joint J,查看原文。版权归原作者所有。

引用

  1. Fransen BL, Bengoa FJ, Neufeld ME, et al. Thin highly cross-linked polyethylene liners combined with large femoral heads in primary total hip arthroplasty show excellent survival and low wear rates at a mean follow-up of 12.8 years. Bone Joint J. 2023. PMID: 36587249. doi:10.1302/0301-620X.105B1.BJJ-2022-0812.R1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。