文献速递关节外科

短柄股骨假体在初次全髋关节置换术中是否与更高的骨折率和早期翻修率相关?一项非劣效性分析

Are Short Stems Associated With Higher Fracture Rates and Early Revision Rates in Primary Total Hip Arthroplasty? A Noninferiority Analysis.
PubMed 文献 · J Arthroplasty · 2023-01-11

该研究基于MARCQI植入物登记系统,对2012至2017年间密歇根州64,084例全髋关节置换术进行回顾性分析,按Khanuja分型比较短柄假体与标准长度假体的90天假体周围骨折率和1年翻修率。结果显示,所有短柄类型在90天骨折率上均达到非劣效性(OR=1.5为临床阈值,P<0.05),Type 3和Type 4短柄在1年翻修率上也达到非劣效性(P<0.05)。结论认为,密歇根州短柄使用增加未导致1年翻修率或90天骨折率升高。

要点

  • 在64,084例初次全髋关节置换中,短柄假体90天骨折率非劣效于标准柄(OR阈值1.5,P<0.05)。
  • Type 3和Type 4短柄的1年翻修率非劣效于标准柄(P<0.05)。
  • 短柄使用增加未导致1年翻修率或90天骨折率升高。

核心结论

  • 密歇根州短柄假体使用增加未导致1年翻修率或90天骨折率升高。

研究设计与样本

  • 基于MARCQI植入物登记系统的回顾性全州数据研究,纳入2012至2017年间64,084例全髋关节置换术。

主要发现

  • 按Khanuja分型,Type 2A短柄3,281例、Type 3短柄1,898例、Type 4短柄19,580例,标准长度Type 5柄33,322例。
  • 总体1年翻修率为1.3%(791/57,853),90天骨折率为1.1%(631/57,968)。
  • 所有短柄类型在90天骨折率上均达到非劣效性(OR=1.5为临床阈值,P<0.05)。
  • Type 3和Type 4短柄在1年翻修率上达到非劣效性(P<0.05)。

关键数值与推荐

  • 非劣效性临床阈值设为OR=1.5,统计学显著性水平为P=0.05。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to determine if "short" femoral stems were noninferior to (at least as good as) standard-length stems in regards to 90-day periprosthetic fracture and 1-year revision rates. METHODS: Using the MARCQI implant registry, a retrospective study of statewide data was carried out on 64,084 total hip arthroplasties (THAs) between 2012 and 2017. We noticed an increase in the use of "short" uncemented femoral hip stems during THA. Chi-square tests were used to test homogeneity of categorical variables. The covariates included in the analyses were identified using modern epidemiological methods. A Type I probability of 0.05 was used as the level of statistical significance. Inverse probability of treatment weighting (IPTW) was used to mitigate confounding variables. RESULTS: One hundred and seven stems were implanted by surgeons in the state of Michigan. They were classified according to the Khanuja Classification System as Type 2A (trapezoidal, double-tapered calcar loading, n = 3,281), Type 3 (calcar loading with lateral flare, n = 1,898), and Type 4 (shortened, tapered, conventional, n = 19,580), and were compared to standard-length, type 5, stems (n = 33,322) in regards to the 2 outcomes (periprosthetic fractures and 1-year revision rates). Overall, 1-year revision and the 90-day fracture rates were 1.3% (791/57,853) and 1.1% (631/57,968), respectively. Noninferiority was established for all short stems at the clinical threshold of an odds ratio (OR) of 1.5 with P-values <0.05 for 90-day fractures. In regards to 1-year revision rates, noninferiority was also established for Type 3 and 4 stems (P < .05). CONCLUSION: The increased use of "short stems" in Michigan did not lead to increased 1-year revision or 90-day fracture rates.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Nelson JT, Zheng H, Hallstrom BR, et al. Are Short Stems Associated With Higher Fracture Rates and Early Revision Rates in Primary Total Hip Arthroplasty? A Noninferiority Analysis. J Arthroplasty. 2023. PMID: 36639113. doi:10.1016/j.arth.2023.01.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。