后内侧半月板根撕裂后半月板突出测量:系统综述与荟萃分析
该系统综述与荟萃分析纳入45项临床与尸体研究,评估后内侧半月板根撕裂(PMMRT)后半月板突出测量技术的异质性及报道的突出值。MRI使用率89%,最常用冠状面参考标志为内侧副韧带(38%),按测量位置汇总的平均突出值分别为3.5±0.7 mm、3.9±0.8 mm和4.5±2.1 mm,不同模态间无显著差异(P=.23)。所有纳入研究汇总的平均半月板突出为3.2±2.0 mm。结论认为测量技术存在显著变异,尤其与冠状面参考位置相关,需进一步研究提供统一测量方法。
要点
- 后内侧半月板根撕裂后半月板突出测量技术异质性大,冠状面参考位置差异显著。
- 最常用冠状面参考标志为内侧副韧带(38%),其次为内侧半月板前后径中点(23%)和内侧股骨髁中点(19%)。
- 按上述三个测量位置汇总的平均突出值分别为3.5±0.7 mm、3.9±0.8 mm和4.5±2.1 mm,不同模态间无显著差异(P=.23)。
核心结论
- 半月板突出测量技术存在显著变异,尤其与冠状面横截面参考位置相关;需进一步研究提供清晰测量方法描述并统一测量方法,以便研究间比较与合并。
研究设计与样本
- 系统综述与荟萃分析,证据等级4级,遵循PRISMA声明,纳入45项报告PMMRT后半月板突出的临床与尸体研究。
主要发现
- 影像模态包括MRI(89%)、三维重建CT(7%)、线性位移传感器(2%)以及MRI与超声联合(2%)。
- 获取冠状面图像测量半月板突出最常用的3个标志为内侧副韧带(38%)、内侧半月板前后径中点(23%)和内侧股骨髁中点(19%)。
- 按测量位置汇总的平均突出值分别为内侧副韧带标志3.5±0.7 mm、内侧半月板前后径中点标志3.9±0.8 mm、内侧股骨髁中点标志4.5±2.1 mm,不同模态类型间无显著差异(P=.23)。
- 所有纳入研究汇总的平均半月板突出为3.2±2.0 mm。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Meniscal extrusion has become increasingly utilized when evaluating meniscus root abnormalities. However, no consensus definition or approach exists on how to measure extrusion. PURPOSE/HYPOTHESIS: The purpose of this study was to evaluate the extent of heterogeneity in meniscal extrusion measurement techniques and reported extrusion values in knees with posterior medial meniscus root tears (PMMRTs). We hypothesized that meniscal extrusion measurement techniques would vary considerably throughout reported studies, with resultant wide-ranging published extrusion values. STUDY DESIGN: Systematic review; Level of evidence, 4. METHODS: A systematic review was conducted according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. The inclusion criteria consisted of all clinical and cadaveric studies reporting on meniscal extrusion after PMMRTs, excluding studies lacking data in full extension, those presenting only semiquantitative analyses, articles reporting only differences in meniscal extrusion, and review articles. RESULTS: A total of 45 studies were included. Imaging modality types included magnetic resonance imaging (89%), 3-dimensional reconstruction with computed tomography (7%), linear displacement transducers (2%), and a combination of magnetic resonance imaging and ultrasound (2%). The 3 most commonly used landmarks to acquire coronal images for meniscal extrusion measurements were the medial collateral ligament (38%), the midpoint of the anterior-posterior length of the medial meniscus (23%), and the middle of the medial femoral condyle (19%). The pooled mean extrusion values according to the measurement location were 3.5 ± 0.7 mm, 3.9 ± 0.8 mm, and 4.5 ± 2.1 mm, respectively, with no significant differences noted between the modality types (P = .23). The pooled mean meniscal extrusion from all included studies was 3.2 ± 2.0 mm. CONCLUSION: Substantial variation exists in measurement techniques for meniscal extrusion, particularly as it relates to the coronal cross-sectional reference location. Further studies should aim to provide clear descriptions of the measurement method and have uniform measurement methodology to allow comparisons and pooling between studies.
引用
- Farivar D, Hevesi M, Fortier LM, et al. Meniscal Extrusion Measurements After Posterior Medial Meniscus Root Tears: A Systematic Review and Meta-analysis. Am J Sports Med. 2022. PMID: 36541434. doi:10.1177/03635465221131005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。