文献速递关节外科

中性粒细胞与淋巴细胞比值、血小板与淋巴细胞比值、单核细胞与淋巴细胞比值及血小板与平均血小板体积比值诊断膝关节假体周围感染的诊断准确性:是否需要性别特异性截断值?

The Diagnostic Accuracy of Neutrophils to Lymphocytes Ratio, Platelets to Lymphocytes Ratio, Monocytes to Lymphocytes Ratio, and Platelets to Mean Platelet Volume Ratio in Diagnosing Periprosthetic Knee Infections. Are Gender-Specific Cutoff Values Needed?
PubMed 文献 · J Arthroplasty · 2022-12-05

本研究纳入261例连续接受全膝关节置换术后疼痛的患者,采用国际共识会议诊断标准识别假体周围感染,评估中性粒细胞与淋巴细胞比值(NLR)、血小板与淋巴细胞比值、单核细胞与淋巴细胞比值(MLR)及血小板与平均血小板体积比值的最佳截断值及其在男性和女性中的诊断准确性。NLR诊断准确性最佳,MLR和NLR在男性和女性中曲线下面积较高;男性MLR≥0.30、女性MLR≥0.17,男性NLR≥2.52、女性NLR≥2.46。结论认为这些生物标志物检测假体周围关节感染的诊断准确性低。

要点

  • NLR在四项比值中诊断准确性最佳,MLR和NLR在男性和女性中曲线下面积较高。
  • 男性MLR≥0.30时敏感度0.71、特异度0.77;女性MLR≥0.17时敏感度0.82、特异度0.29。
  • 男性NLR≥2.52时敏感度0.71、特异度0.88;女性NLR≥2.46时敏感度0.54、特异度0.76。

核心结论

  • 这些生物标志物检测假体周围关节感染的诊断准确性低。
  • MLR和NLR高于截断值的男性出现脓毒性假体失败的概率分别为77%和88%。
  • NLR至少2.46对女性假体周围膝关节感染具有合理的敏感性。

研究设计与样本

  • 诊断研究,证据等级II。
  • 纳入261例连续接受全膝关节置换术后疼痛的患者。
  • 采用国际共识会议诊断标准识别假体周围感染。
  • 计算每个截断值的敏感度、特异度、阳性预测值和阴性预测值,并评估受试者工作特征曲线下面积。

主要发现

  • NLR报告了最佳诊断准确性。
  • MLR和NLR在男性和女性中报告了较高的曲线下面积。
  • 男性MLR最佳截断值为≥0.30,女性为≥0.17;男性敏感度和特异度分别为0.71和0.77,女性分别为0.82和0.29。
  • 男性NLR最佳截断值为≥2.52,女性为≥2.46;男性敏感度和特异度分别为0.71和0.88,女性分别为0.54和0.76。

关键数值与推荐

  • MLR男性最佳截断值≥0.30,女性最佳截断值≥0.17。
  • NLR男性最佳截断值≥2.52,女性最佳截断值≥2.46。
  • 男性MLR≥0.30时敏感度0.71、特异度0.77;女性MLR≥0.17时敏感度0.82、特异度0.29。
  • 男性NLR≥2.52时敏感度0.71、特异度0.88;女性NLR≥2.46时敏感度0.54、特异度0.76。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: This study aimed to assess the most appropriate thresholds for neutrophils to lymphocytes ratio (NLR), platelets to lymphocytes ratio, monocytes to lymphocytes ratio (MLR), and platelets to mean platelet volume ratio in patients who had a suspected prosthetic knee infection. Furthermore, we evaluated the diagnostic accuracy of our proposed thresholds by men and women. METHODS: A total of 261 consecutive patients affected by painful total knee arthroplasty were included. International Consensus Meeting diagnostic criteria were used to identify periprosthetic infections. Sensitivity, specificity, positive, and negative predictive values were calculated for each cutoff value obtained. The area under the receiver operating characteristic curve was evaluated. RESULTS: NLR reported the best diagnostic accuracy. MLR and NLR reported higher area under the curves in men and women. We obtained an MLR value ≥0.30 (optimal cutoff value for men) and ≥0.17 (optimal cutoff value for women). In men, the sensitivity and the specificity were 0.71 and 0.77, respectively, versus 0.82 and 0.29, in women. For NLR, we obtained a value ≥2.52 (best cutoff value for men) and ≥2.46 (best cutoff value for women). These cutoffs reported a sensitivity and specificity of 0.71 and 0.88 versus 0.54 and 0.76 in men and women, respectively. CONCLUSION: These biomarkers present a low diagnostic accuracy in periprosthetic joint infection detection. Men whose MLR and NLR were above cutoff values had a 77 and 88% probability of presenting a septic prosthetic failure. NLR of at least 2.46 was reasonably sensitive for women who have a periprosthetic knee infection. LEVEL OF EVIDENCE: Diagnostic study, Level II.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Balato G, Ascione T, Festa E, et al. The Diagnostic Accuracy of Neutrophils to Lymphocytes Ratio, Platelets to Lymphocytes Ratio, Monocytes to Lymphocytes Ratio, and Platelets to Mean Platelet Volume Ratio in Diagnosing Periprosthetic Knee Infections. Are Gender-Specific Cutoff Values Needed? J Arthroplasty. 2022. PMID: 36481284. doi:10.1016/j.arth.2022.11.014

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。