新型人工智能算法将二维X线片转换为全膝关节置换术三维骨模型的准确性、可靠性和可重复性
本研究评估一种新型人工智能算法将二维X线片转换为三维骨模型在5例尸体膝关节上的测量准确性、观察者间与观察者内可靠性及可重复性;与CT扫描和手动卡尺测量相比,12个解剖参数中9个的平均绝对误差小于2mm,所有观察者间和观察者内相关系数均大于0.90。
要点
- 与CT和手动卡尺测量相比,12个解剖参数中9个的平均绝对误差小于2mm。
- 所有观察者间和观察者内相关系数均大于0.90,表明测量可靠性和可重复性高。
- 该算法无需三维成像即可将二维X线片转换为类似CT扫描的三维骨重建,具有成本和时间的效率优势。
核心结论
- 该人工智能算法在将二维X线片转换为三维骨重建方面表现出高准确性、可靠性和可重复性,效果类似CT扫描。
研究设计与样本
- 开发一种将二维X线片转换为三维骨模型重建的人工智能算法,并在5例尸体膝关节上评估其准确性、可靠性和可重复性。
主要发现
- 与CT扫描和手动卡尺测量相比,12个解剖参数中9个的平均绝对误差小于2mm。
- 所有观察者间和观察者内相关系数均大于0.90,表明独立观察者和同一观察者的测量可靠性和可重复性高。
关键数值与推荐
- 准确性评估指标为平均绝对误差,与CT扫描和手动卡尺测量相比,12个解剖参数中9个的平均绝对误差小于2mm。
- 可靠性及可重复性评估指标为观察者间和观察者内相关系数,所有系数均大于0.90。
临床怎么用
- 研究结果表明该人工智能算法因其成本和时间的效率优势以及无需三维成像即可减少辐射暴露,具有用于术前手术规划的潜力。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: With the emergence of advanced technology, such as robotics, three-dimensional (3D) imaging is necessary to execute preoperative surgical plans accurately. However, 3D imaging adds cost and potential risk to patients. This study determined the measurement accuracy, reliability, and repeatability of a novel artificial intelligence (AI) algorithm which converts two-dimensional (2D) radiographs to 3D bone models. METHODS: An AI algorithm was developed to convert 2D radiographs to 3D bone model reconstructions. The accuracy of the AI algorithm was evaluated by comparing mean absolute error in measurements performed on 3D bone reconstructions, 3D computed tomography (CT) scans, and manual measurements on five cadaveric knees. Reliability and repeatability of the AI algorithm were evaluated by assessing the inter-observer and intra-observer agreement between measurements performed on 3D bone reconstructions, respectively. RESULTS: Accuracy of the AI algorithm was considered excellent with mean absolute errors <2mm in 9 of 12 anatomical parameters compared with measurements performed on CTs and manual calipers. All inter-observer and intra-observer correlation coefficients were greater than 0.90 representing a high level of measurement reliability and repeatability by independent observers and the same observers. CONCLUSION: This particular AI algorithm demonstrated a high degree of accuracy, reliability, and repeatability for converting 2D radiographs to 3D bone reconstructions similar to a CT-scan. Study results suggest this AI algorithm has the potential for use in preoperative surgical planning due to its efficiencies related to cost and time and reduced radiation exposure without the use of 3D imaging.
引用
- Fernandes LR, Arce C, Martinho G, et al. Accuracy, Reliability, and Repeatability of a Novel Artificial Intelligence Algorithm Converting Two-Dimensional Radiographs to Three-Dimensional Bone Models for Total Knee Arthroplasty. J Arthroplasty. 2022. PMID: 36503105. doi:10.1016/j.arth.2022.12.007
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。