文献速递关节外科

陶瓷对陶瓷界面初次全髋关节置换术:单中心1083髋至少10年随访分析

Primary Total Hip Arthroplasty With Ceramic-On-Ceramic Articulations: Analysis of a Single-Center Series of 1,083 Hips at a Minimum of 10-Year Follow-Up.
PubMed 文献 · J Arthroplasty · 2022-12-15

该研究评估单术者陶瓷对陶瓷(CoC)全髋关节置换术至少10年临床与影像学结局及生存率。796例患者(1083髋)平均随访11年,11年生存率98.3%(翻修或无菌性松动)和98.2%(再手术),平均mHHS 93分、WOMAC 14.4分,131髋(12%)出现摩擦音但无需翻修,无陶瓷碎裂。

要点

  • 11年生存率:翻修或无菌性松动98.3%,再手术98.2%。
  • 末次随访平均mHHS 93分,WOMAC 14.4分。
  • 131髋(12%)出现摩擦音,无患者需翻修,无陶瓷碎裂。

核心结论

  • 陶瓷对陶瓷界面全髋关节置换术至少10年具有高生存率和优异功能结局。

研究设计与样本

  • 单中心、单术者系列,2008年至2011年间初次全髋关节置换术1039例患者(1391髋)中,排除49例(69髋)瘫痪或死亡及194例(239髋,19%)失访后,796例患者(1083髋)完成评估,平均随访11年(范围10至13年)。

主要发现

  • 11年生存率:翻修或无菌性松动为98.3%,再手术为98.2%。
  • 末次随访平均mHHS为93分(范围12至100),平均WOMAC为14.4分(范围3至66)。
  • 131髋(12%)出现摩擦音,无患者需翻修;未观察到陶瓷碎裂。
  • 末次随访影像学评估869髋:3髋(0.3%)松动,2髋(0.2%)股骨骨溶解,81髋(9.3%)出现透亮线,35髋(4%)异位骨化。

局限性

  • 194例患者(239髋,19%)失访。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: There are limited long-term results of using ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) in a large number of patient cohorts. The purpose of this study was to evaluate the minimum 10-year clinical and radiological outcomes and survivorship in a single surgeon series of CoC-THA. METHODS: Among the 1,039 patients (1,391 hips) who underwent primary THA at our institution between 2008 and 2011, 49 patients (69 hips) experienced paralysis or death, and 194 patients (239 hips, 19%) were lost to follow-up. The remaining 796 patients (1,083 hips) were assessed at a mean of 11 years (range, 10 to 13 years) using the modified Harris hip score (mHHS), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and a questionnaire on articular noises. Survival analysis was used to estimate the survivorship. Radiological evaluation was performed on 869 hips at the final follow-up. RESULTS: Survivorship at 11 years was 98.3% for revision or aseptic loosening, and 98.2% for reoperation. At the final follow-up, the mean mHHS and WOMAC scores were 93 (range, 12 to 100) and 14.4 (range, 3 to 66), respectively. There were 131 (12%) hips that experienced squeaking, but no patient required revision. No fracture of the ceramic was observed. Radiological evaluation at the final follow-up revealed that 3 (0.3%) hips exhibited loosening, 2 (0.2%) had femoral osteolysis, 81(9.3%) acquired radiolucencies, and 35 (4%) showed heterotopic ossification. CONCLUSION: This CoC bearing for THA had a high survivorship and excellent functional outcomes for at least 10 years.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Niu E, Fu J, Li H, et al. Primary Total Hip Arthroplasty With Ceramic-On-Ceramic Articulations: Analysis of a Single-Center Series of 1,083 Hips at a Minimum of 10-Year Follow-Up. J Arthroplasty. 2022. PMID: 36529193. doi:10.1016/j.arth.2022.12.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。