后稳定型全膝关节置换术在屈曲位的冠状面松弛度大于交叉韧带保留型手术
本研究回顾性比较了75例交叉韧带保留型(CR)与72例后稳定型(PS)全膝关节置换术患者,随访至少2年。PS-TKA在屈膝80°时的内翻、外翻及总松弛度均显著大于CR-TKA,而伸直位无显著差异;影像学与临床结果无统计学差异,但CR-TKA功能评分略优。屈曲位内翻松弛度与临床评分及活动度呈不良相关。
要点
- PS-TKA在屈膝80°的内翻、外翻和总松弛度均显著大于CR-TKA。
- 伸直位冠状面松弛度在两组间无显著差异。
- 屈曲位内翻松弛度与WOMAC、mHSS评分及活动度呈不良相关。
核心结论
- PS-TKA在屈膝80°的冠状面松弛度大于CR-TKA,且较大的屈曲位内翻松弛度对临床结果产生不良影响。
- 作者认为手术中应注意维持冠状面稳定性,尤其是在屈曲位,以获得更好的患者报告结果。
研究设计与样本
- 回顾性评估75例CR-TKA与72例PS-TKA,随访至少2年。
- 在膝关节伸直位和屈膝80°时,通过内翻和外翻应力X线片评估冠状面松弛度。
- 影像学评估包括股胫角、髋-膝-踝角和股骨与胫骨假体位置;临床评估包括改良特种外科医院评分、WOMAC骨关节炎指数和活动度。
- 证据等级为III级。
主要发现
- PS-TKA在屈膝80°的内翻、外翻和总松弛度显著大于CR-TKA(P值分别为.034、.031和0.001)。
- 伸直位内翻、外翻和总松弛度在CR-TKA与PS-TKA之间无显著差异(P值分别为.513、.964和.658)。
- CR-TKA与PS-TKA在影像学和临床结果方面无统计学差异,但CR-TKA的功能评分略优。
- 屈曲位内翻松弛度与WOMAC指数、改良特种外科医院评分和活动度呈不良相关(r值分别为0.933、-0.229和-0.472)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: It is unclear whether coronal stability differs between cruciate-retaining (CR) and posterior-stabilized (PS) total knee arthroplasty (TKA). The purpose of this study was to compare coronal laxity, radiological, and clinical outcomes between CR-TKA and PS-TKA. METHODS: Seventy five CR-TKAs and 72 PS-TKAs with a minimum 2-year follow-up were retrospectively evaluated. Coronal laxity was assessed at knee extension and 80° of flexion on varus and valgus stress radiographs. Radiological evaluation included femoral-tibial angle, hip-knee-ankle angle, and positions of femoral and tibial components. Clinical evaluation included the modified Hospital for Special Surgery score, the Western Ontario and McMaster Universities Osteoarthritis index, and range of motion. RESULTS: PS-TKA resulted in significantly larger varus, valgus, and total laxities at 80° flexion (P = .034, .031, and 0.001, respectively) compared with CR-TKA, while no significant difference was found at extension (P = .513, .964, and .658, respectively). No statistical difference was found in radiological and clinical outcomes between CR-TKA and PS-TKA, but the functional scores were slightly better in CR-TKA. There were adverse correlations between varus laxity at flexion and the Western Ontario and McMaster Universities Osteoarthritis index, the modified Hospital for Special Surgery score, and range of motion (r = 0.933, -0.229, -0.472, respectively). CONCLUSION: Coronal laxity at 80° of flexion was larger after PS-TKA than CR-TKA. In addition, clinical outcomes were adversely affected by the larger varus laxity at flexion. Care should be taken to maintain the coronal stability, especially at flexion, during surgery to obtain better patient-reported outcomes. LEVEL OF EVIDENCE: Level III.
引用
- Hao K, Niu Y, Feng A, et al. Coronal Laxity at Flexion is Larger After Posterior-Stabilized Total Knee Arthroplasty Than With Cruciate-Retaining Procedures. J Arthroplasty. 2022. PMID: 36584764. doi:10.1016/j.arth.2022.12.041
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。