文献速递关节外科创伤骨科

髋关节置换股骨柄设计与早期术后假体周围股骨骨折的关联

Hip Arthroplasty Femoral Stem Designs and Their Association With Early Postoperative Periprosthetic Femoral Fractures.
PubMed 文献 · J Arthroplasty · 2022-12-16

这项多中心回顾性研究纳入2014至2021年3433例初次非骨水泥全髋关节置换,比较单锥度与双锥度股骨柄设计对早期Vancouver B型或其他需手术干预的假体周围股骨骨折风险的影响。控制混杂变量后,带领压配柄较单锥度和双锥度柄显著降低术后Vancouver B型及需手术治疗的假体周围股骨骨折风险。

要点

  • 带领压配柄的Vancouver B型骨折风险低于其他柄型(HR 0.18)。
  • 带领压配柄需手术治疗的假体周围股骨骨折风险降低(HR 0.10)。
  • 压配填充柄术中骨折发生率最高(3.6%)。

核心结论

  • 控制混杂变量后,带领压配柄较单锥度和双锥度柄显著降低术后Vancouver B型及需手术治疗的假体周围股骨骨折风险。

研究设计与样本

  • 多中心回顾性研究纳入2014至2021年3433例初次非骨水泥全髋关节置换,平均随访2.2年(范围0.3至6.5年)。
  • 单锥度柄2302例(微型M/L柄1169例;M/L柄1133例),双锥度柄1131例(压配填充柄420例;带领压配柄711例)。

主要发现

  • 术后假体周围股骨骨折45例(1.3%),中位发生时间8.8周,其中Vancouver B型25例(0.7%),需手术干预20例(0.6%)。
  • 带领压配柄Vancouver B型风险降低(HR 0.18,95%CI 0.03-0.97,P=0.044),任何需手术治疗的假体周围股骨骨折风险降低(HR 0.10,95%CI 0.01-0.95,P=0.037)。
  • 术中假体周围股骨骨折最常见于压配填充柄(3.6%,P<0.001),Vancouver A型骨折最常见于带领压配柄(1.8%,P<0.001)。
  • 发生假体周围股骨骨折的队列Charlson合并症指数更高(P=0.004)、女性更多(P=0.001)、Dorr A或C型股骨更多(P=0.013)、后侧或外侧手术入路更多(P≤0.001)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA), especially those in contact with the diaphyseal stem, carry high morbidity. This study evaluated how stem design influences the risk of early Vancouver B PFF or other PFF requiring operative intervention after THA. METHODS: A multicenter, retrospective study of 3,433 primary cementless THAs performed from 2014 to 2021 included 2,302 single-taper (micro M/L [n = 1,169]; M/L [n = 1,133]) and 1,131 double-taper (fit-and-fill [n = 420]; compaction-collared [n = 711]) stems. Mean follow-up was 2.2 years (range, 0.3 to 6.5 years). Primary outcomes were Vancouver B and surgically treated postoperative PFFs among differing femoral stems. Secondary outcomes included rates of intraoperative and postoperative Vancouver A and C PFFs. RESULTS: Forty five postoperative PFFs (1.3%) occurred within 8.8 weeks (median), 25 of which were Vancouver B (0.7%) and 20 total PFFs that required operative intervention (0.6%). Compaction-collared stems had a decreased risk of Vancouver B (hazard ratio 0.18, 95% confidence interval: 0.03-0.97 P = .044) and any surgically treated PFF (hazard ratio 0.10, 95% confidence interval: 0.01-0.95; P = .037). Intraoperative PFFs were most common with fit-and-fill stems (3.6%, P < .001) and Vancouver A with compaction-collared stems (1.8%, P < .001). The cohort with PFF had a higher Charlson comorbidity index (P = .004), more women (P = .001), more Dorr A or C femora (P = .013), and more posterior or lateral surgical approaches compared to those without PFF (P ≤ .001). CONCLUSION: After controlling for confounding variables, compaction-collared stems had a significantly lower risk of postoperative Vancouver B and PFF requiring operative treatment than single-taper and double-taper stems.

来源:J Arthroplasty,查看原文。版权归原作者所有。

引用

  1. Calkins TE, Goetz DD, Zalewski JT, et al. Hip Arthroplasty Femoral Stem Designs and Their Association With Early Postoperative Periprosthetic Femoral Fractures. J Arthroplasty. 2022. PMID: 36535442. doi:10.1016/j.arth.2022.12.020

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。